[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-388366-105":59,"doc-detail-388366-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","removal-of-cetylpyridinium-chloride-cpc-from-personal-care-product-wastewater-by-nyextm-case-study","Removal of Cetylpyridinium Chloride (CPC) from Personal Care Product Wastewater by NyexTM - Case Study","","A personal care products manufacturer engaged Arvia to bolt on a targeted solution to reduce cetylpyridinium chloride (CPC) in wastewater. The study evaluates the NyexTM process, combining adsorption media with electrochemical oxidation, to lower CPC below 50 mg/L to meet local discharge regulations and avoid costly off-site wastewater transport. Results from Arvia’s laboratory Nyex 1-20a system show CPC reduction to 16 mg/L and 90% removal, while avoiding chemical dosing and sludge generation.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/removal-of-cetylpyridinium-chloride-cpc-from-personal-care-product-wastewater-by-nyextm-case-study/388366/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/removal-of-cetylpyridinium-chloride-cpc-from-personal-care-product-wastewater-by-nyextm-case-study/388366.png","ImageObject",300,407,{"name":92,"@type":93},"Riley","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-06","2026-09-25",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",12,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What problem does the case study address?","Question",{"text":113,"@type":114},"The case study addresses targeted reduction of cetylpyridinium chloride (CPC) in personal care product wastewater to meet local regulatory discharge limits.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How does the NyexTM process work in this solution?",{"text":118,"@type":114},"NyexTM combines adsorption with electrochemical oxidation in a modular, scalable unit, concentrating organics on proprietary non-porous, high-conductivity media and enabling continuous targeted oxidation.",{"name":120,"@type":111,"acceptedAnswer":121},"What removal performance was achieved in the trials?",{"text":122,"@type":114},"On the laboratory Nyex 1-20a system, CPC was reduced to about 16 mg/L with 90% CPC removal, exceeding the requirement to be below 50 mg/L while also achieving about 90% COD removal.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},388366,1790708958,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":24,"preview_page_count":14,"preview_urls":145},1374391975076,"https://ap-avatar.wpscdn.com/avatar/14000253ca4ec9f6853?x-image-process=image/resize,m_fixed,w_180,h_180&k=1783305029341752051","CASE STUDY  \nRemoval of Cetylpyridinium Chloride (CPC) from Personal  \nCare Product Wastewater by NyexTM  \nBackground  \nA manufacturer of Personal Care Products approached Arvia looking for a solution to bolt-on to their existing wastewater treatment train for the targeted reduction of Cetylpyridinium Chloride (CPC) .  \nThe chemical is commonly found in mouthwashes, toothpastes, lozenges, throat sprays, nasal sprays and asan ingredient in certain pesticide formulations.  \nCPC has antiseptic properties which are used to kill bacteria and other microorganisms. Investigations have been carried out on microbial communities exposed to CPC in order to evaluate the chemical’s impact on antimicrobial resistance (AMR) . After 10 weeks of exposure, the microbial community tested was found tobe less susceptible to CPC. This indicates the chemical’s ability to alter the behaviour of microbial communities, leaving them resistant to its antiseptic properties.  \nThe results of Arvia’s project will have important implications in propelling further studies on how the exposure of CPC can contribute to AMR, as this could affect both aquatic species and human health.  \nFull scale NyexTM containerised system  \nThe Objectives  \nThe aim of this trial was to demonstrate and evaluate the effectiveness of the NyexTM process in the reduction of CPC levels in wastewater.  \nThe manufacturer wanted to reduce CPC to below 50 mg/L from a complex wastewater for discharge in  \nline with their local regulation. The client had recently upgraded their product manufacturing portfolio and needed to upgrade their wastewater treatment facility in order for their wastewater to continue to be compliant and avoid regulatory fines.  \nSuccessful removal of CPC will prevent the need for transporting wastewater off-site to achieve the required treatment levels. The ongoing process of trucking wastewater off-site is not only costly but also and has negative environmental implications.  \n[arviatechnology.com](arviatechnology.com)  \nRemoval of Cetylpyridinium Chloride (CPC) from Personal Care Product Wastewater by NyexTM CASE STUDY  \nThe Solution  \nArvia ’s Nyex-a system combines adsorption with electrochemical oxidation in a single , scalable unit. Organic contaminants are concentrated on the surface of Arvia’s proprietary adsorption media , which is non-porous with high electrical conductivity.  \nThis patented adsorbent media allows for targeted and continuous oxidation. Unlike granular activated carbon , NyexTM media is effectively regenerated in-situ and the process can continue without interruption or replacement.  \nResults are achieved without chemical dosing or the generation of sludge , reducing costs in terms of transport of chemicals and specialist waste disposal. NyexTM treated wastewater can also be reused in-process or in other areas of the business , such as for cleaning and toilet flushing to reduce utility costs.  \nThe system provides a chemical free and environmentally sound solution , which comes in a modular design and can be bolted onto an existing treatment process. The NyexTM process parameters are easily adjusted to suit amends to production outputs and seasonality, ensuring wastewater treatment remains effective despite these changes.  \nThe trials were carried out on Arvia’s laboratory scale Nyex 1-20a system.  \nFigure 1 – Schematic of Arvia’s NyexTM Technology  \n\n| The Results\u003Cbr>The Nyex-a system successfully removed CPC to exceed the requirement of 50 mg/L , achieving 16mg/L COD , as shown in Figure 2.\u003Cbr>\u003Cbr>Client target-below 50 mg/LCPC\u003Cbr>l Influent water-202 mg/L CPC\u003Cbr>l NyexTM Treated Water:\u003Cbr>-16 mg/L CPC\u003Cbr>-90% CPC removal\u003Cbr>-90% COD removal | | |  |\n| --- | --- | --- | --- |\n|  | \u003Cbr>Figure 2 – CPC Removal by Arvia’s laboratory Nyex 1-20a system , against treatment time. |  |  |\n| Recommendations\u003Cbr>These results demonstrate the capability of the NyexTM process to deal with a range of CPC concentrations to provide removal exceeding the r","cbCaifg0jXJVDoP7","https://ap.wps.com/l/cbCaifg0jXJVDoP7","pdf",1127182,"English","# Background\n# The Objectives\n# The Solution\n# The Results\n# Recommendations","[{\"question\":\"What problem does the case study address?\",\"answer\":\"The case study addresses targeted reduction of cetylpyridinium chloride (CPC) in personal care product wastewater to meet local regulatory discharge limits.\"},{\"question\":\"How does the NyexTM process work in this solution?\",\"answer\":\"NyexTM combines adsorption with electrochemical oxidation in a modular, scalable unit, concentrating organics on proprietary non-porous, high-conductivity media and enabling continuous targeted oxidation.\"},{\"question\":\"What removal performance was achieved in the trials?\",\"answer\":\"On the laboratory Nyex 1-20a system, CPC was reduced to about 16 mg/L with 90% CPC removal, exceeding the requirement to be below 50 mg/L while also achieving about 90% COD removal.\"}]","Removal of Cetylpyridinium Chloride (CPC) from Personal Care Product Wastewater by NyexTM - Case Study | PDF",1790302286,[146,150],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/20979d3eac296e8fbb71fb32a76d37a9.webp",983,1378,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/a5a936658fc7ab35ed7dfd454eaef041.webp",982,1377]