[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-647443-105":59,"doc-detail-647443-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","remote-thermo-hygro-sensor-model-thgn132n-user-manual","Remote Thermo-Hygro Sensor Model - THGN132N - User Manual","","Remote Thermo-Hygro Sensor Model THGN132N user manual explains the device overview, including LED status, wall mount hole, battery compartment, RESET function, and channel switching. It guides sensor setup by inserting batteries with correct polarity, selecting channels 1–3, pressing RESET after battery changes, and initiating sensor search on the main unit. It provides best-placement recommendations, troubleshooting for reading or connection issues, safety precautions, and complete remote-unit specifications (dimensions, ranges, resolution, signal frequency, transmission distance, channels, and power).",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/remote-thermo-hygro-sensor-model-thgn132n-user-manual/647443/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/remote-thermo-hygro-sensor-model-thgn132n-user-manual/647443.png","ImageObject",300,407,{"name":92,"@type":93},"bocahgabuttt","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-08","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"How do I set up the THGN132N sensor and start receiving data?","Question",{"text":112,"@type":113},"Install batteries in the remote sensor first, set a channel (1, 2, or 3), press RESET after inserting batteries, then initiate a sensor search on the main unit to begin receiving temperature and humidity data.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What should I do if the remote sensor shows abnormal readings or strange values?",{"text":117,"@type":113},"Press RESET on the remote sensor to return it to the default behavior, then recheck the readings.",{"name":119,"@type":110,"acceptedAnswer":120},"What troubleshooting steps apply if the main unit cannot locate the remote sensor?",{"text":121,"@type":113},"Check the battery, confirm the sensor location, and ensure channel configuration is correct; if needed, initiate a manual sensor search.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},647443,1792788882,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":24,"preview_page_count":4},962094248839,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","Remote Thermo-Hygro Sensor Model: THGN132N  \nUSER MANUAL  \nEN  \nOVERVIEW  \nFRONT VIEW (FIG. 1)  \n1  \n1. LED status indicator: blinks when transmitting a reading  \nBACK VIEW (FIG. 2)  \n1. Wall mount hole  \n2. Battery compartment  \n3. RESET: Reset unit to default settings  \n4. Channel Switch  \nGETTING STARTED  \nSENSOR SET UP  \n1. Slide open the battery door.  \n2. Slide channel switch to select a channel (1, 2, 3) . Ensure you use a different channel for each sensor.  \n3. Insert the battery, matching the polarities (+ / -) . See FIG 2.  \n4. Press RESET after each battery change.  \n5. Close the battery door.  \nNOTE Install battery in the remote sensor before the main unit.  \n6. Initiate a sensor search on the main unit to start receiving temperature / humidity data from the sensor.  \n7. Secure the sensor in the desired location using the wall mount or table stand.  \nFor best results:  \n• Place the sensor within 30 m (100 ft) of the main unit.  \n• Place the sensor out of direct sunlight and moisture.  \n• Position the sensor so that it faces the main (indoor) unit, minimizing obstructions such as doors, walls and furniture.  \n• Place the sensor in a location with a clear view to the sky, away from metallic / electronic objects.  \n• Position the sensor close to the main unit during cold winter months as below-freezing temperatures may affect battery performance and signal transmission.  \nTIP The transmission range may vary depending on many factors. You may need to experiment with various locations to get the best results.  \nNOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing.  \nCHANGING CHANNELS  \nTo change channels once channel has been assigned:  \n1. Slide channel switch to desired channel.  \n2. Press RESET.  \n3. Initiate a sensor search on the main unit to start receiving temperature / humidity data from the sensor.  \nRESET  \nPress RESET to return to the default settings.  \nTROUBLE SHOOTING  \n\n| PROBLEM | SYMPTOM | REMEDY |\n| --- | --- | --- |\n| Remote sensor | Abnormal /\u003Cbr>strange readings | Press RESET |\n|  | Cannot locate\u003Cbr>remote sensor | Check battery |\n|  |  | Check location |\n|  | Cannot change channel | Check sensors.\u003Cbr>Only one sensor is working |\n|  | Data does not match main unit | Initiate a manual sensor search |\n\nPRECAUTIONS  \n• Do not subject the unit to excessive force, shock, dust, temperature or humidity  \n• Do not cover the ventilation holes with any items such s newspapers, curtains etc.  \n• Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth.  \n• Do not clean the unit with abrasive or corrosive materials.  \n• Do not tamper with the unit ’s internal components. This invalidates the warranty.  \n• Only use fresh batteries. Do not mix new and old batteries.  \n• Images shown in this manual may differ from the actual display.  \n• When disposing of this product, ensure it is collected separately for special treatment.  \n• Placement of this product on certain types of wood may result in damage to its ﬁnish for which Oregon Scientiﬁc will not be responsible. Consult the furniture manufacturer's care instructions for information.  \n• The contents of this manual may not be reproduced without the permission of the manufacturer.  \n• Do not dispose old batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.  \n• Please note that some units are equipped with a battery safety strip. Remove the strip from the battery compartment before ﬁrst use.  \nNOTE The technical speciﬁcations for this product and the contents of the user manual are subject to change without notice.  \nSPECIFICATIONS  \n\n| TYPE | DESCRIPTION |\n| --- | --- |\n\nREMOTE UNIT  \n\n| L x W x H | 117 x 80 x 171 mm (4 .78 x 3.27 x 6.98 in) |\n| --- | --- |\n| Weight | 241 g (8 .5 oz) without battery |\n| Temperature range | -20°C to 60°C\u003Cbr>(-4°F to 140°F) |\n| Resolution | 0. 1°C (0 .2°F) |\n| Humid","cbCaiguNM9PPvi84","https://ap.wps.com/l/cbCaiguNM9PPvi84","pdf",6406659,"English","# Overview\n## Front View (Fig. 1)\n## Back View (Fig. 2)\n# Getting Started\n## Sensor Set Up\n## Changing Channels\n## Reset\n# Troubleshooting\n# Precautions\n# Specifications","[{\"question\":\"How do I set up the THGN132N sensor and start receiving data?\",\"answer\":\"Install batteries in the remote sensor first, set a channel (1, 2, or 3), press RESET after inserting batteries, then initiate a sensor search on the main unit to begin receiving temperature and humidity data.\"},{\"question\":\"What should I do if the remote sensor shows abnormal readings or strange values?\",\"answer\":\"Press RESET on the remote sensor to return it to the default behavior, then recheck the readings.\"},{\"question\":\"What troubleshooting steps apply if the main unit cannot locate the remote sensor?\",\"answer\":\"Check the battery, confirm the sensor location, and ensure channel configuration is correct; if needed, initiate a manual sensor search.\"}]","Remote Thermo-Hygro Sensor Model - THGN132N - User Manual | PDF"]