[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-203773-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-203773-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","rectangular-industrial-connectors-heavy-duty-multipole-connectors","Rectangular Industrial Connectors - Heavy Duty Multipole Connectors","","Heavy duty multipole connector documentation detailing bases, hoods, covers, and inserts for rectangular industrial use. Provides part-number cross references to OEM codes, specifies pole configurations (3 or 4 poles and additional series options), wire conductor ranges, and electrical ratings such as 10A/16A and up to 600V. Includes guidance for enclosure protection levels (IP44, IP66/IP67), seal-and-screw kit requirements, and notes on compatible hoods/bases, material variants, and non-stock black options.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/rectangular-industrial-connectors-heavy-duty-multipole-connectors/203773/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/rectangular-industrial-connectors-heavy-duty-multipole-connectors/203773.png","ImageObject",300,407,{"name":42,"@type":43},"Aria","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-10","2026-09-04",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",7,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What connector components are listed in this document?","Question",{"text":63,"@type":64},"It covers heavy duty multipole connectors including bases, hoods, covers, and inserts, with part numbers and OEM equivalents.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"What wire conductor ranges and electrical ratings are provided?",{"text":68,"@type":64},"The document specifies wire conductor ranges by series (e.g., 18 ÷ 14 AWG, 22 ÷ 14 AWG, 22 ÷ 12 AWG) and ratings such as 10A max-600V and 16A max-600V.",{"name":70,"@type":61,"acceptedAnswer":71},"How are IP44 and IP66/IP67 protection requirements achieved?",{"text":72,"@type":64},"IP44 is noted as applicable to enclosures with pegs, and IP66/IP67 requires a seal-and-screw kit fitted under the insert fastening screw; CQ12 inserts may already include seal and screw.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},203773,1788563605,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,105,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":103,"slug":104},6,50,"technology",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":102,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":33,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":80,"read_time":123},2336464648322,"https://ap-avatar.wpscdn.com/avatar/2200025388227c56fec?_k=1778556882303663488","HEAVY DUTY MULTIPOLE CONNECTORS  \nBases  \nSeries A 3 or 4 poles+ ⏚  \n\n| Part \\# | Crimp Terminal | OEM Part \\# |\n| --- | --- | --- |\n| APML03SP | single lever, insulating type (white) | CK 03 I |\n| APML03S | single lever, metal type (grey) | CKAS 03 I |\n\n\n| Pg Part \\# | Pg | NPT Part \\# | NPT | Angled Panel Mounting Bases | OEM Part \\# |\n| --- | --- | --- | --- | --- | --- |\n| APML03SAP |  |  |  | single lever, insulating type (white) | CK 03 IA |\n| APML03SA |  |  |  | single lever, metal type (grey) | CKAS 03 IA |\n| AS1L03SA2P | 11 | AS1L03SA9P | 3/8\" | single lever, single port, insulating type (white) | CK 03 IAP |\n| AS1L03SA2 | 11 | AS1L03SA9 | 3/8\" | single lever, single port, metal type (grey) | CKAS 03 IA |\n\nCable glands not included.  \nHoods  \nSeries A 3 or 4 poles+ ⏚  \n\n| Pg Part \\# | Pg | NPT Part \\# | NPT | Hoods | OEM Part \\# |\n| --- | --- | --- | --- | --- | --- |\n| ATEP03S2P | 11 | ATEP03S9P | 3/8\" | two pegs, top entry, insulating type (white) | CK 03 V |\n| ATEP03S2 | 11 | ATEP03S9 | 3/8\" | two pegs, top entry, metal type (grey) | CKA 03 V |\n| ATEP03SA2P | 11 | ATEP03SA9P | 3/8\" | two pegs, top entry, angled, insulating type (white) | CK 03 VA |\n| ATEP03SA2 | 11 | ATEP03SA9 | 3/8\" | two pegs, top entry, angled, metal type (grey) | CKA 03 VA |\n| ACC03S2P | 11 | ACC03S9P | 3/8\" | single lever, cable coupler, insulating type (white) | CK 03 VG |\n| ACC03S2 |  11  | ACC03S9 |  3/8\"  |  single lever, cable coupler, metal type (grey)  |  CKAX 03 VGS |\n\nCable glands not included.  \nCovers  \nSeries A 3 or 4 poles+ ⏚  \n\n| Part \\# | Covers | OEM Part \\# |\n| --- | --- | --- |\n| AP03SLP | two pegs, insulating type (white) (female inserts) | CK 03 C |\n| AP03SLP1 | two pegs, insulating type (white) (male inserts) |  |\n| AP03SL | two pegs, metal type (grey) (female inserts) | CKA 03 C |\n| AP03SL1 | two pegs, metal type (grey) (male inserts) |  |\n| AL03SLP | single lever, insulating type (white) (male inserts) | CK 03 CXA |\n| AL03SLP1 | single lever, gasket, insulating type (white) (female inserts) |  |\n| AL03SL | single lever, metal type (grey) (male inserts) | CKAX 03 CXA |\n| AL03SL1 | single lever, gasket, metal type (grey) (female inserts) |  |\n\nToll Free Tel: 1.800.701.0975 • Toll Free Fax: 1.800.892.6360 • [orders@elecdirect.com](orders@elecdirect.com)  \ns ize 21.21  \nCK and MK enclosures  \noverall dimensions:  \n21 x 21 mm  \ndescription  \nwith pegs, top entry 1)  \nwith pegs, side entry 1)  \nwith lever in galvanised steel, top entry 1)  \nwith stainless steel lever, top entry 1) with pegs and gasket, for female inserts with pegs, for male inserts  \nwith stainless steel lever and gasket, for female inserts with stainless steel lever, for male inserts  \nseal and screw kit for IP66/IP673) for CK, CQ 05, CKS inserts  \nseal and screw kit for IP66/IP673) for CD 08 inserts  \n1) enclosures with IP44 degree of protection.  \n2) better to use with CKAX enclosures (stainless steel lever) .  \n3) To achieve the IP66/PI67 protection rating, a kit is available which includes a seal to be fitted under the insert fastening screw supplied with the kit (see example illustrated), instead of the screw with spring washer supplied with the insert  \nNote:  \nThe CQ 12 inserts are already fitted with seal and screw, allowing IP66/IP67 protection rating to be achieved.  \nE  \nType 12  \nType 4/4X only with CKR 65 (D)  \ndimensions shown are not binding and may be changed without notice  \nsize “21 .21” metal version  \nhoods  \npart No.  \n(entry-Pg 11)  \nCKA 03 VS  \nCKA 03 VAS  \nCKA 03 VGS  \nCKAX 03 VGS  \nCKR 65  \nCKR 65 D  \ndimensions in mm CKA VS and MKA V  \npart No.  \n(entry-M 20)  \nMKA V20  \nMKA VA20  \nMKA VG20  \nMKAX VG20  \nPg 11 or M 20  \ncovers  \npart No.  \nCKA 03 C 2)  \nCKA 03 CA 2)  \nCKAX 03 CX  \nCKAX 03 CXA  \ndimensions in mm  \nCKA C  \n33.5  \n60.5  \n􀀂 26.5  \n33.5 􀀂 28  \n17.5  \nCKA VAS and MKA VA  \nPg 11 or M 20  \n53  \n33.5  \nCKA VGS and MKA VG 32  \n􀀂 26.5  \n􀀂 24  \nCKA CA  \n33.5  \n􀀂 26.5 17.5  \nCKAX CX  \n33 20  \n51.5  \nPg 11 or M 20  \n􀀂 24 48.5  \nCK","cbCais49ljFIHMml","https://ap.wps.com/l/cbCais49ljFIHMml","pdf",1950452,"English","# Heavy duty multipole connectors\n## Bases, hoods, and covers\n## Inserts and electrical ratings\n## General features of multipole connectors","[{\"question\":\"What connector components are listed in this document?\",\"answer\":\"It covers heavy duty multipole connectors including bases, hoods, covers, and inserts, with part numbers and OEM equivalents.\"},{\"question\":\"What wire conductor ranges and electrical ratings are provided?\",\"answer\":\"The document specifies wire conductor ranges by series (e.g., 18 ÷ 14 AWG, 22 ÷ 14 AWG, 22 ÷ 12 AWG) and ratings such as 10A max-600V and 16A max-600V.\"},{\"question\":\"How are IP44 and IP66/IP67 protection requirements achieved?\",\"answer\":\"IP44 is noted as applicable to enclosures with pegs, and IP66/IP67 requires a seal-and-screw kit fitted under the insert fastening screw; CQ12 inserts may already include seal and screw.\"}]","Rectangular Industrial Connectors - Heavy Duty Multipole Connectors | PDF"]