[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-663443-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-663443-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","rccy03x-coriolis-mass-flow-and-density-meter-signal-cable-wiring-9-wire-cable","RCCY03x Coriolis Mass Flow and Density Meter - Signal Cable Wiring - 9-wire cable","","Specification and wiring instructions for RCCY031/032, RCCY033/034 and RCCY03x cables used with a Coriolis mass flow and density meter system. Covers construction options (shielded twisted pairs/triples and coaxial configurations), applicable flame propagation requirement IEC 60332-1, and electrical characteristics such as resistance, capacitance, and inductance per model. Includes detector-to-converter wiring maps for 9-wire and coaxial-line cables and detailed termination procedures, including required shrink tubes, sleeves, labels, and careful assembly requirements for correct measurement performance.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/rccy03x-coriolis-mass-flow-and-density-meter-signal-cable-wiring-9-wire-cable/663443/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/rccy03x-coriolis-mass-flow-and-density-meter-signal-cable-wiring-9-wire-cable/663443.png","ImageObject",300,407,{"name":42,"@type":43},"adawds","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",5,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"Which cable models and temperature ranges are covered?","Question",{"text":63,"@type":64},"The document lists RCCY031/032 (-50 to +70°C), RCCY033/034 (-30 to +105°C), and RCCY03x variants with coax. It also provides sub-variants with /KS1 and /NS1 suffixes.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"What flame propagation standard applies to these cables?",{"text":68,"@type":64},"Flame propagation must meet IEC 60332-1. The requirement is stated for the specified RCCY cable constructions.",{"name":70,"@type":61,"acceptedAnswer":71},"How should the customer terminate the coaxial cable for RCCY03x-0 Lxxx?",{"text":72,"@type":64},"The customer must terminate the cable using the supplied termination set (Mat. No. M3813WJ). The procedure includes removing the PVC sheath and shielding, preparing single wires or coax shields, and using the specified shrink tubes and terminal sleeves to ensure correct detector-to-converter connection.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},663443,1793227781,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,100,104,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":102,"slug":103},6,50,"technology",{"id":105,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},7,"Healthcare",40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":55,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":101,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":101,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":80,"read_time":143},3985747872983,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","Drawings Models RCCY031, RCCY032,   \nRCCY033, RCCY034  \nCoriolis Mass Flow and Density Meter  \nRemote Cable  \nSpecification:  \nLi2Y(St)/CY 3x2 AWG24 + 1x3 AWG20, pair/triple shielded; pair/triple twisted; overall shielding RCCY033/034 and RCCY031/032/KS1: flame propagation acc. IEC 60332-1.  \nor 3 x Coax + 1x3 AWG20, shielded, twisted; overall shielding; flame propagation acc. IEC 60332-1.  \n\n| Model code | Temperature\u003Cbr>range | Wire gauge | Resistance of\u003Cbr>loop | Capacitance\u003Cbr>wire/wire | Capacitance\u003Cbr>wire/shield | Inductance\u003Cbr>wire/wire |\n| --- | --- | --- | --- | --- | --- | --- |\n| RCCY031/032 | -50 to +70°C | AWG 24\u003Cbr>AWG 20 | 190 Ω/km\u003Cbr>70 Ω/km | 157 nF/km\u003Cbr>193 nF/km | 249 nF/km\u003Cbr>290 nF/km | 0.60 mH/km\u003Cbr>0.65 mH/km |\n| RCCY031/032 /KS1\u003Cbr>RCCY031/032 /NS1 | -50 to +70°C | AWG 24\u003Cbr>AWG 20 | 190 Ω/km\u003Cbr>70 Ω/km | 157 nF/km\u003Cbr>193 nF/km | 249 nF/km\u003Cbr>290 nF/km | 0.60 mH/km\u003Cbr>0.65 mH/km |\n| RCCY033/034 | -30 to +105°C | AWG 24\u003Cbr>AWG 20 | 177 Ω/km\u003Cbr>70 Ω/km | 175 nF/km\u003Cbr>145 nF/km | 350 nF/km\u003Cbr>290 nF/km | 0.80 mH/km\u003Cbr>0.70 mH/km |\n| RCCY033/034 /KS1\u003Cbr>RCCY033/034 /NS1 | -30 to +105°C | AWG 24\u003Cbr>AWG 20 | 177 Ω/km\u003Cbr>70 Ω/km | 175 nF/km\u003Cbr>145 nF/km | 350 nF/km\u003Cbr>290 nF/km | 0.80 mH/km\u003Cbr>0.70 mH/km |\n| RCCY03x with coax | -50 to +105°C | Coax\u003Cbr>AWG 20 | 37 Ω/km\u003Cbr>70 Ω/km | 120 nF/km\u003Cbr>145 nF/km | 132 nF/km\u003Cbr>290 nF/km | 0.175 mH/km\u003Cbr>0.70 mH/km |\n\nSignal Cable Wiring:  \n9-wire cable  \n\n| Detector RCCS3[] | Cable | Converter RCCF31 / RCCR31 |\n| --- | --- | --- |\n| D + | 1---------------------------------------------------1 | D + |\n| D- | 2---------------------------------------------------2 | D- |\n| S1 + | 3---------------------------------------------------3 | S1 + |\n| S1- | 4---------------------------------------------------4 | S1- |\n| S2 + | 5---------------------------------------------------5 | S2 + |\n| S2- | 6---------------------------------------------------6 | S2- |\n| TP1 | 7---------------------------------------------------7 | TP1 |\n| TP2 | 8---------------------------------------------------8 | TP2 |\n| TP3 | 9---------------------------------------------------9 | TP3 |\n|  | ---------------------------------------------------shields | COM |\n\nCable with coaxial lines  \n\n| Detector RCCS3[] | Cable | Converter RCCF31 / RCCR31 |\n| --- | --- | --- |\n| D + | 1---------------------------------------------------1\u003Cbr>----------------------shield--------------------- | D + |\n| D- |  | D- |\n| S1 + | 2---------------------------------------------------2\u003Cbr>----------------------shield--------------------- | S1 + |\n| S1- |  | S1- |\n| S2 + | 3---------------------------------------------------3\u003Cbr>----------------------shield--------------------- | S2 + |\n| S2- |  | S2- |\n| TP1 | 4---------------------------------------------------4\u003Cbr>5---------------------------------------------------5\u003Cbr>6---------------------------------------------------6\u003Cbr>---------------------------------------------------shields | TP1 |\n| TP2 |  | TP2 |\n| TP3 |  | TP3 |\n|  |  | COM |\n\nRota Yokogawa GmbH & Co. KG Rheinstr. 8  \nD-79664 Wehr, Germany  \nAll Right Reserved, Copyright 􀂤 2005, Rota Yokogawa SD 01R04B04-05E-E 1/6  \nSubject to change without notice. 7th edition, August 2013  \nexcl. Japan  \nTermination procedure for cable with coaxial lines:  \nFor RCCY03x-0 Lxxx the customer has to terminate the cable by his own.  \nThe termination set (Mat. No. M3813WJ) contains:  \n- Instruction M3813WD  \n-2 x 20mm shrink down tube, Ø 5mm  \n-6 x 10mm shrink down tube  \n-6 x tube di = 1mm, length 10mm  \n-6 markers (2 x 1–3)  \n-6 markers (2 x 4–6)  \n- 18 sleeves 0.5mm² orange  \n- 1 sleeves 0.25mm² light blue  \n- 1 label “CONVERTER”  \n- 1 label “FLOWMETER”  \n- 1 label “RCCY03”  \n NOTE  \nCareful assembly of the cable is indispensable for correct connection between the detector and the converter. This ensures good measuring results.  \nCable end detector  \n- Remove PVC outer sheath and outer shielding 100mm from the end.  \n- Remove the cle","cbCaimIFyNKZ48yt","https://ap.wps.com/l/cbCaimIFyNKZ48yt","pdf",275440,"English","# Coriolis mass flow and density meter cable specifications\n## Cable construction and flame propagation requirement (IEC 60332-1)\n## Electrical parameters by model\n## Signal cable wiring (9-wire and coaxial lines)\n## Termination procedure for coaxial cable","[{\"question\":\"Which cable models and temperature ranges are covered?\",\"answer\":\"The document lists RCCY031/032 (-50 to +70°C), RCCY033/034 (-30 to +105°C), and RCCY03x variants with coax. It also provides sub-variants with /KS1 and /NS1 suffixes.\"},{\"question\":\"What flame propagation standard applies to these cables?\",\"answer\":\"Flame propagation must meet IEC 60332-1. The requirement is stated for the specified RCCY cable constructions.\"},{\"question\":\"How should the customer terminate the coaxial cable for RCCY03x-0 Lxxx?\",\"answer\":\"The customer must terminate the cable using the supplied termination set (Mat. No. M3813WJ). The procedure includes removing the PVC sheath and shielding, preparing single wires or coax shields, and using the specified shrink tubes and terminal sleeves to ensure correct detector-to-converter connection.\"}]","RCCY03x Coriolis Mass Flow and Density Meter - Signal Cable Wiring - 9-wire cable | PDF",15]