[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-460409-105":59,"doc-detail-460409-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","rare-malposition-of-central-venous-catheter-repositioned-under-ultrasound-guidance","Rare Malposition of Central Venous Catheter - Repositioned Under Ultrasound Guidance","","Letter to the editor describing a rare misdirection of a right internal jugular central venous catheter into the right subclavian vein in a middle-aged patient presenting with septic shock. After dysfunction of both lumens and an abnormal chest X-ray course, clinicians used sterile guidewire repositioning under ultrasound visualization, with contrast-enhanced ultrasound to confirm placement. A follow-up radiograph further validated correction while avoiding catheter reinsertion or a second venipuncture, emphasizing operator vigilance and ultrasound use for real-time verification.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/rare-malposition-of-central-venous-catheter-repositioned-under-ultrasound-guidance/460409/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/rare-malposition-of-central-venous-catheter-repositioned-under-ultrasound-guidance/460409.png","ImageObject",300,407,{"name":92,"@type":93},"acoobca","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-08","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What rare complication does the letter report?","Question",{"text":112,"@type":113},"A right internal jugular central venous catheter acutely angulated into the right subclavian vein.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How was the malposition confirmed and repositioned?",{"text":117,"@type":113},"A sterile guidewire was inserted under ultrasound visualization and contrast-enhanced ultrasound (CEUS) confirmed correct placement, with follow-up chest radiography for validation.",{"name":119,"@type":110,"acceptedAnswer":120},"Why is ultrasound guidance emphasized in this case?",{"text":121,"@type":113},"The letter highlights that ultrasound can support not only initial CVC insertion but also real-time repositioning and verification to improve patient safety and procedural success.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},460409,1790758407,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":24,"preview_page_count":4},3985747870733,"https://ap-avatar.wpscdn.com/davatar_a8503ba1806abce46bf441b54a3ca4cd","Letters to Editor  \nRare Malposition of Central Venous Catheter – Repositioned  \nUnder Ultrasound Guidance  \nDear Editor,  \nCentral venous catheters (CVCs) are indispensable tools in emergency and critical care for fluid administration, vasopressor support, renal replacement therapy, and other advanced interventions. The right internal jugular vein (IJV) is often the preferred access route due to its anatomical proximity and lower risk of complications.[1,2] Nevertheless, malpositioning can occur despite best practices. This letter discusses a rare malposition of CVC with an acute angulation  \ninto the right subclavian vein from a right IJV approach, which was successfully repositioned using ultrasound guidance anda sterile guidewire – thus avoiding catheter reinsertion or a second venipuncture.  \nA middle‑aged female presented to the emergency department in septic shock, with a right IJV CVC in situ, but two lumens failed to demonstrate backflow. The chest X-ray revealed an unusual course: the catheter originated in the right IJVand acutely  \nJournal of Emergencies, Trauma, and Shock ¦ Volume 18 ¦ Issue 4 ¦ October-December 2025 201   \nLetters to Editor  \nangulatedintothe right subclavian vein [Figure 1a]. Recognizing the malposition, a sterile guidewire was inserted under ultrasonographic visualization, and the catheter was repositioned. A contrast-enhanced ultrasound (CEUS) confirmed correct placement, further validated by a follow-up chest radiograph.  \nFor optimal visualization, a high-frequency linear (5–12 MHz) probe was used. The guidewire’s progression was tracked in realtime at the cavoatrial junction [Figure 1b] and confirmed using CEUS, which involves injecting a saline–air mixture through the catheter to observe the bubble transit within the heart. Correct catheter placement results in immediate visualization of microbubbles in the right atrium [Figure 1c]; delayed or turbulent appearance indicates malposition, prompting repositioning.[3]  \nThis case also emphasizes the importance of operator vigilance. Though malposition into the IJV from subclavian access is reported, the reverse – where a right IJV catheter enters the right subclavian vein – is extremely rare and, to our knowledge, undocumented. Factors such as anatomical variations, guidewire manipulation errors, vessel tortuosity, and angulated branches may contribute to such misdirection.[4,5]  \nClinicians must maintain a high indexof suspicion formalposition in cases with dysfunctional lumens or unexpected resistance. Resistance during advancement should prompt immediate reevaluation through ultrasound or fluoroscopic assistance.[4]  \nThe letter demonstrates that ultrasound can be employed not just for initial CVC insertion but also for real-time repositioning. In conclusion, this rare instance of a right IJV catheter misdirected into the right subclavian vein highlights both an unusual complication and a minimally invasive correction technique. This letter supports the integration of ultrasound not only for CVC insertion but also as verification protocols to enhance patient safety and procedural success.  \nThanking You,  \nResearch quality and ethics statement  \nThe authors followed applicable EQUATOR Network ([https://](https://)  \nFigure 1: (a) Central venous catheter originated in the right internal jugular vein and acutely angulated into the right subclavian vein. (b) The guidewire’s tip tracked in real time at the cavoatrial junction, confirming correct positioning. (c) Visualization of microbubbles in the right atrium  \n[www.equator-network.org/](www.equator-network.org/)) guidelines, notably the CARE guideline, during the conduct of this report.  \nDeclaration of patient consent  \nThe authors certify that they have obtained all appropriate patient consent forms. In the form, the patient has given her consent for her images and other clinical information to be reported in the journal. The patient understands that her name and initials will not be publi","cbCaifZCtshi49af","https://ap.wps.com/l/cbCaifZCtshi49af","pdf",617872,"English","# Letters to Editor\n## Rare malposition and ultrasound-guided repositioning\n## Ultrasound visualization and CEUS confirmation\n## Clinical vigilance and implications","[{\"question\":\"What rare complication does the letter report?\",\"answer\":\"A right internal jugular central venous catheter acutely angulated into the right subclavian vein.\"},{\"question\":\"How was the malposition confirmed and repositioned?\",\"answer\":\"A sterile guidewire was inserted under ultrasound visualization and contrast-enhanced ultrasound (CEUS) confirmed correct placement, with follow-up chest radiography for validation.\"},{\"question\":\"Why is ultrasound guidance emphasized in this case?\",\"answer\":\"The letter highlights that ultrasound can support not only initial CVC insertion but also real-time repositioning and verification to improve patient safety and procedural success.\"}]","Rare Malposition of Central Venous Catheter - Repositioned Under Ultrasound Guidance | PDF"]