[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-290339-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-290339-en":131},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","radiometer-calibration-using-machine-learning-290339","Radiometer calibration using machine learning","","Radiometers are key instruments in radio astronomy, converting electromagnetic intensity into electrical signals through an antenna and low-noise amplifier (LNA). Calibration must correct receiver-induced effects, but impedance mismatches can create reflections and distortions that complicate traditional approaches such as Dicke switching using a reference source. Machine learning methods, especially neural networks trained on known signal sources, can model complex receiver behavior. The work introduces and tests a machine-learning calibration framework aimed at the precision needed to detect high-redshift 21-cm signals.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/radiometer-calibration-using-machine-learning-290339/290339/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/radiometer-calibration-using-machine-learning-290339/290339.png","ImageObject",300,407,{"name":42,"@type":43},"Aurora","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-17","2026-09-17",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",17,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What problem does radiometer calibration address?","Question",{"text":63,"@type":64},"It corrects receiver-introduced instrumental effects so the measured electrical signals accurately reflect incoming electromagnetic radiation.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How can impedance mismatch affect radiometer measurements?",{"text":68,"@type":64},"Impedance mismatches between the antenna and receiver can cause unwanted signal reflections and distortions.",{"name":70,"@type":61,"acceptedAnswer":71},"Why is machine learning calibration especially relevant for detecting 21-cm signals?",{"text":72,"@type":64},"Neural networks can learn complex system behavior from known signal sources, enabling the precision required for faint high-redshift 21-cm line detection.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},290339,1789641411,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,120,123,127],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":117,"show_sort_weight":118,"slug":119},9,"Religion & Spirituality",20,"religion-spirituality",{"id":118,"doc_module":4,"doc_module_name":25,"category_name":121,"show_sort_weight":118,"slug":122},"World Cup","world-cup",{"id":124,"doc_module":4,"doc_module_name":25,"category_name":125,"show_sort_weight":124,"slug":126},10,"Lifestyle","lifestyle",{"id":128,"doc_module":4,"doc_module_name":25,"category_name":129,"show_sort_weight":97,"slug":130},19,"General","general",{"code":4,"msg":82,"data":132},{"doc_id":79,"user_id":133,"nickname":42,"user_avatar":134,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":140,"language":141,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":12,"update_tm":80,"read_time":109,"preview_page_count":33,"preview_urls":145},4810365810221,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","University of Groningen  \nRadiometer calibration using machine learning  \nLeeney, S. A. K. ; Bevins, H. T.J. ; Acedo, [E. de](E. de) Lera; Handley, W. J. ; Kirkham, C. ; Patel, R. S. ; Zhu, J. ; Molnar, D. ; Cumner, J. ; Anstey, D.  \nPublished in: Scientific Reports  \nDOI:  \n10.1038/s41598-025-16732-9  \nIMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from it. Please check the document version below.  \nDocument Version  \nPublisher's PDF, also known as Version of record  \nPublication date: 2025  \nLink to publication in University of Groningen/UMCG research database  \nCitation for published version (APA):  \nLeeney, S. A. K. , Bevins, H. T. J. , Acedo, E. D. L. , Handley, W. J. , Kirkham, C. , Patel, R. S. , Zhu, J. , Molnar, D. , Cumner, J. , Anstey, D. , Artuc, K. , Bernardi, G. , Bucher, M. , Carey, S. , Cavillot, J. , Chiello, R. , Croukamp, W. , de Villiers, D. I. L. , Ely, J. A. , ... Spinelli, M. (2025) . Radiometer calibration using machine learning. Scientific Reports, 15(1), Article 34335. [https://doi.org/10.1038/s41598-025-16732-9](https://doi.org/10.1038/s41598-025-16732-9)  \nCopyright  \nOther than for strictly personal use, it is not permitted to download or to forward/distribute the text or part of it without the consent of the author(s) and/or copyright holder(s), unless the work is under an open content license (like Creative Commons) .  \nThe publication may also be distributed here under the terms of Article 25fa of the Dutch Copyright Act, indicated by the “Taverne” license. More information can be found on the University of Groningen website: [https://www.rug.nl/library/open-access/self-archiving-pure/taverne](https://www.rug.nl/library/open-access/self-archiving-pure/taverne)amendment.  \nTake-down policy  \nIf you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim.  \nDownloaded from the University of Groningen/U MCG research database (Pure): [http://www.rug. nl/research/portal. For technical reasons the](http://www.rug. nl/research/portal. For technical reasons the)[ ](http://www.rug. nl/research/portal. For technical reasons the)[number of authors shown on this cover page is limited to 10 maximum.](number of authors shown on this cover page is limited to 10 maximum.)  \nDownload date: 30-12-2025  \n[www. nature.com/scientificreports](www. nature.com/scientificreports)  \nOPEN  \nRadiometer calibration using machine learning  \nS. A. K. Leeney1,2,16􀀍, H. T. J. Bevins1,2,16, [E. de](E. de) Lera Acedo1,2,16, W. J. Handley2,3,16, C. Kirkham1,2,16, R. S. Patel1,2,16, J. Zhu1,2,4,16,19, D. Molnar1,2,16, J. Cumner1,2,16,  \nD. Anstey1,2,16, K. Artuc1,2,16, G. Bernardi5,16, M. Bucher6,7,16, S. Carey1,16, J. Cavillot8,16, R. Chiello9,16, W. Croukamp7,16, D. I. L. de Villiers7,16, J. A. Ely1,16, A. Fialkov2,3,16,  \nT. Gessey-Jones1,2,16, G. Kulkarni10,16, A. Magro11,16, P. D. Meerburg12,16, S. Mittal1,2,16,  \nJ. H. N. Pattison1,16, S. Pegwal7,13,16, C. M. Pieterse7,16, J. R. Pritchard14,16, E. Puchwein15,16,  \nN. Razavi-Ghods1,16, I. L. V. Roque1,16, A. Saxena12,16, K. H. Scheutwinkel1,2,16, P. Scott1,16,  \nE. Shen1,2,16, P. H. Sims1,2,16 & M. Spinelli16,17,18  \nRadiometers are crucial instruments in radio astronomy, forming the primary component of nearly all radio telescopes. They measure the intensity of electromagnetic radiation, converting this radiation into electrical signals. A radiometer’s primary components are an antenna and a Low Noise Amplifier (LNA), which is the core of the “receiver” chain. Instrumental effects introduced by the receiver are typically corrected or removed during calibration. However, impedance mismatches between the antenna and receiver can introduce unwanted signal reflections and distortions. Traditional calibration methods, such as Dicke switching, alternate the receiver input between the antenna and a wellcharacterised referen","cbCaim95SpIFzd7O","https://ap.wps.com/l/cbCaim95SpIFzd7O","pdf",3597614,16,"English","# Introduction\n## Radiometer role in radio astronomy\n## Calibration challenges from impedance mismatch\n## Machine learning calibration approach\n## Relevance to high-redshift 21-cm detection","[{\"question\":\"What problem does radiometer calibration address?\",\"answer\":\"It corrects receiver-introduced instrumental effects so the measured electrical signals accurately reflect incoming electromagnetic radiation.\"},{\"question\":\"How can impedance mismatch affect radiometer measurements?\",\"answer\":\"Impedance mismatches between the antenna and receiver can cause unwanted signal reflections and distortions.\"},{\"question\":\"Why is machine learning calibration especially relevant for detecting 21-cm signals?\",\"answer\":\"Neural networks can learn complex system behavior from known signal sources, enabling the precision required for faint high-redshift 21-cm line detection.\"}]","Radiometer calibration using machine learning | PDF",[146,150,154,158],{"page_no":22,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/2bfb03b44c49f52d6d10e96c3533029a.webp",983,1390,{"page_no":26,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/408f78c4b56146a1488fc774f4486454.webp",982,1290,{"page_no":30,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/cc3b4a28458fc4c53508b03d424a9fcc.webp",981,1289,{"page_no":33,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/6e23353f5e7797e0d7ae240647d8a260.webp",980,1287]