[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-656647-105":59,"doc-detail-656647-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","r16-roof-tile-cad-details-roofing-snow-guards-and-roof-constructions","R.16 ROOF TILE - CAD DETAILS - Roofing snow guards and roof constructions","","R.16 ROOF TILE CAD DETAILS document provides installation and construction diagrams for roof tile systems, emphasizing roof safety, watertight junctions, and ventilation. It includes contents covering minimum roof pitch, snow guard installation diagrams (1–3) and key roof constructions such as single-skin and double-skin assemblies, ridge and hip components, eaves variants with different gutter brackets, flashing types, valleys, anchors, and roof window flashing for different pitch ranges. It also references engineering product versioning and governing standards for structural snow loads.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/r16-roof-tile-cad-details-roofing-snow-guards-and-roof-constructions/656647/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/r16-roof-tile-cad-details-roofing-snow-guards-and-roof-constructions/656647.png","ImageObject",300,407,{"name":92,"@type":93},"Ezra","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-01","2026-10-25",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What topics are covered in the R.16 roof tile CAD details contents?","Question",{"text":112,"@type":113},"The contents list snow guard installation diagrams, minimum roof pitch, and detailed construction assemblies including single-skin and double-skin roofs, ridge and hip components, eaves with gutters, flashing types, valleys, and roof window flashing.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How are snow guards installed according to the R.16 installation diagrams?",{"text":117,"@type":113},"The document provides separate installation diagram references for R.16 snow guards (1, 2, and 3), including placement requirements along the first two rows and specified quantities per square meter.",{"name":119,"@type":110,"acceptedAnswer":120},"Which roof constructions are included for different roof assembly types?",{"text":121,"@type":113},"It includes both single-skin and double-skin roof constructions, plus ridge construction variants (ridge vent and hip cap) and mono-pitched roof construction, each broken down into component layers and fixings.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},656647,1793037142,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},1099514068035,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","| | R.16 | ROOF TILE\u003Cbr>CAD DETAILS |\n| --- | --- | --- |\n| \u003Cbr>CONTENTS:\u003Cbr>2 MINIMUM ROOF PITCH\u003Cbr>3 snow guards – installation diagram R.16 1\u003Cbr>4 snow guards – installation diagram R.16 2\u003Cbr>5 snow guards – installation diagram R.16 3\u003Cbr>6 single-skin roof construction\u003Cbr>7 double-skin roof construction\u003Cbr>8 ridge construction—ridge vent\u003Cbr>9 ridge construction—hip cap\u003Cbr>10 mono-pitched roof construction\u003Cbr>11 eaves construction with gutter\u003Cbr>12 eaves construction with box gutter\u003Cbr>13 eaves construction with upright gutter bracket\u003Cbr>14 eaves construction with upright gutter bracket (variant 1)\u003Cbr>15 eaves construction with upright gutter bracket (variant 2)\u003Cbr>16 eaves construction with on-roof gutter\u003Cbr>17 roof verge construction with verge flashing\u003Cbr>18 roof verge construction with recess\u003Cbr>19 roof verge construction with bargeboard\u003Cbr>20 wall flashing\u003Cbr>21 roof parapet flashing\u003Cbr>22 lateral wall connection\u003Cbr>23 valley construction with safety valley\u003Cbr>24 valley construction with simple valley\u003Cbr>25 valley construction with recessed valley\u003Cbr>26 valley construction with recessed valley\u003Cbr>27 frog-mouth vent cover\u003Cbr>28 roof anchor hook\u003Cbr>29 Roof window flashing on a roof pitch over 25° .\u003Cbr>30 Roof window flashing with an insert wedge on a roof pitch over 25° .\u003Cbr>31 Roof window flashing with wedge frames under 15°\u003Cbr>32 Roof window flashing with wedge frames under 15°\u003Cbr>33 mansard crease\u003Cbr>34 construction of pitch transition\u003Cbr>35 Vario (or Fix) solar bracket\u003Cbr>36 pipe-style snow guard system\u003Cbr>37 pipe-style snow guard system XL\u003Cbr>38 mountain snow-guard bracket\u003Cbr>39 roof anchor hook according on mounts\u003Cbr>40 safety tread\u003Cbr>41 walkway support\u003Cbr>Product Engineering Version: 03.07.2023 020204_EN_Details_Dach R.16_PREFA_2023-Q3 page 1 |  |  |\n\n| | snow guards – installation diagram R.16 1\u003Cbr>R.16 ROOF TILE\u003Cbr>CAD DETAILS |\n| --- | --- |\n| Installation diagram R.16 1 (1,7 per m²—must be installed along the first two rows) Basic principle: ÖNORM B 1991-1-3 and EN 1991-1-3\u003Cbr>Product Engineering Version: 03.07.2023 020204_EN_Details_Dach R.16_PREFA_2023-Q3 page 3 |  |\n\n| | snow guards – installation diagram R.16 2 R.16 ROOF TILE\u003Cbr>CAD DETAILS |\n| --- | --- |\n| installation diagram R.16 2 (3,4 pc. per m² ; must be installed along the first two rows) Basic principle: ÖNORM B 1991-1-3 and EN 1991-1-3\u003Cbr>Product Engineering Version: 03.07.2023 020204_EN_Details_Dach R.16_PREFA_2023-Q3 page 4 |  |\n\n| | snow guards – installation diagram R.16 3 R.16 ROOF TILE\u003Cbr>CAD DETAILS |\n| --- | --- |\n| installation diagram R.16 3 (6,8 pc. per m²)\u003Cbr>Basic principle: ÖNORM B 1991-1-3 and EN 1991-1-3\u003Cbr>Product Engineering Version: 03.07.2023 020204_EN_Details_Dach R.16_PREFA_2023-Q3 page 5 |  |\n\n| | single-skin roof construction R.16 ROOF TILE |\n| --- | --- |\n| 1\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>hip and ridge cap\u003Cbr>2 ventilation for roof tiles R. 16 via frog-mouth vents 3 R.16 ROOF TILE\u003Cbr>4 roof underlay\u003Cbr>5 Solid sheathing conforming to national guidelines\u003Cbr>6 rafters\u003Cbr>7 edge cleat strip for R.16 roof tile\u003Cbr>8 snow guard for R.16 roof tile 9\u003Cbr>10 eaves apron strip\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>10\u003Cbr>\u003Cbr>7\u003Cbr>possible ventilation\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>4\u003Cbr>\u003Cbr>outgoing air\u003Cbr>\u003Cbr>outgoing air\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>30–80*\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>11 edge board\u003Cbr>CAD DETAILS\u003Cbr>hip and ridge batten, 30 mm wide (height may differ according to roof gradient)\u003Cbr>\u003Cbr>\u003Cbr>8\u003Cbr>\u003Cbr>1\u003Cbr>\u003Cbr>9\u003Cbr>\u003Cbr>2\u003Cbr>\u003Cbr>\u003Cbr>5\u003Cbr>\u003Cbr>3\u003Cbr>\u003Cbr>11\u003Cbr> The eaves projection must not exceed 80 mm.\u003Cbr>Product Engineering Version: 03.07.2023 020204_EN_Details_Dach R.16_PREFA_2023-Q3 page 6 |  |\n\n| | double-skin roof construction R.16 ROOF TILE |\n| --- | --- |\n| |  CAD DETAILS |\n| \u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>1 ridge vent\u003Cbr>2 snow guard for R.16 roof tile\u003Cbr>3 R.16 ROOF TILE\u003Cbr>4 Solid sheathing conforming to national guidelines\u003Cbr>5 count","cbCaiaPkLCmrJbkx","https://ap.wps.com/l/cbCaiaPkLCmrJbkx","pdf",2661333,41,"English","# Contents\n## Minimum roof pitch\n## Snow guards – installation diagrams (R.16 1, R.16 2, R.16 3)\n## Roof constructions\n## Ridge, hip, and eaves constructions\n## Flashing, valleys, and connections\n## Roof accessories and anchors","[{\"question\":\"What topics are covered in the R.16 roof tile CAD details contents?\",\"answer\":\"The contents list snow guard installation diagrams, minimum roof pitch, and detailed construction assemblies including single-skin and double-skin roofs, ridge and hip components, eaves with gutters, flashing types, valleys, and roof window flashing.\"},{\"question\":\"How are snow guards installed according to the R.16 installation diagrams?\",\"answer\":\"The document provides separate installation diagram references for R.16 snow guards (1, 2, and 3), including placement requirements along the first two rows and specified quantities per square meter.\"},{\"question\":\"Which roof constructions are included for different roof assembly types?\",\"answer\":\"It includes both single-skin and double-skin roof constructions, plus ridge construction variants (ridge vent and hip cap) and mono-pitched roof construction, each broken down into component layers and fixings.\"}]","R.16 ROOF TILE - CAD DETAILS - Roofing snow guards and roof constructions | PDF",1792969750,103]