[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-291534-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-291534-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","qualification-report-ansiesd-s2020-scs-r3-dissipative-rubber-mat","Qualification Report – ANSI/ESD S20.20 - SCS R3 Dissipative Rubber Mat","","Qualification Report – ANSI/ESD S20.20 evaluates a SCS R3 dissipative rubber mat using surface resistance testing under controlled environmental conditions. Measurements are reported as resistance to groundable point and resistance point-to-point, taken after 48–72 hours conditioning at 12% RH and 50% RH (23°C), with N=3 specimens and a 100V test voltage. Data include pass thresholds, per-position sample results, and statistical min/mean/max values. Test methods reference ANSI/ESD STM4.1, with calibration and equipment listed for the corporate lab environment chamber and resistance measurement instruments.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/qualification-report-ansiesd-s2020-scs-r3-dissipative-rubber-mat/291534/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/qualification-report-ansiesd-s2020-scs-r3-dissipative-rubber-mat/291534.png","ImageObject",300,407,{"name":42,"@type":43},"Pentious","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-31","2026-09-17",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",8,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What standard and product are qualified in this report?","Question",{"text":63,"@type":64},"The report qualifies an SCS R3 dissipative rubber mat under ANSI/ESD S20.20.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How are resistance results measured and under what conditions?",{"text":68,"@type":64},"Resistance is measured as resistance to a groundable point and resistance point-to-point after 48–72 hours conditioning at 12% RH and 50% RH (23°C), using 100V and N=3 specimens.",{"name":70,"@type":61,"acceptedAnswer":71},"Which test method and references are used for the data tables?",{"text":72,"@type":64},"Test methods reference ANSI/ESD STM4.1, and the figures are identified for work-surface measurements: Figure 1 for resistance-to-groundable point and Figure 2 for resistance point-to-point.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},291534,1789645838,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":55,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":26,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":80,"read_time":97,"preview_page_count":4},1374404730887,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","QUALIFICATION REPORT – ANSI/ESD S20.20  \nSCS R3 DISSIPATIVE RUBBER MAT  \n\n| ANSI/ESDS20.20 | SCS Test Results | Test Methods |\n| --- | --- | --- |\n\nResistance (ohms) @ 12% RH, 23°C, 48-72 hours conditioning, N=3 specimens, 100V  \n\n| Resistance-to-Groundable point | \u003C 1.0 x 109 | See Table 1 | ANSI/ESD STM4.1 |\n| --- | --- | --- | --- |\n| Resistance Point-to-Point | \u003C 1.0 x 109 | See Table 2 | ANSI/ESD STM4.1 |\n\n\n| Resistance-to-Groundable point | \u003C 1.0 x 109 | See Table 1 | ANSI/ESD STM4.1 |\n| --- | --- | --- | --- |\n| Resistance Point-to-Point | \u003C 1.0 x 109 | See Table 2 | ANSI/ESD STM4.1 |\n\nResistance (ohms) @ 50% RH, 23°C, 48-72 hours conditioning, N=3 specimens, 100V  \nTesting Equipment (Calibration records and test results are located at our corporate lab (Canton, MA)):  \n- Environment Chamber with ETS Automatic Humidity Controller (Model 514)  \n- Desco Electrodes for Surface Resistance (Model 50003)  \n- Desco Surface Resistance Meter (Model 19291)  \nTest Data:  \nTable 1-Resistance-to-Groundable point  \n\n|  | RTG (ohms), at 12%RH, 23°C |  |  | RTG (ohms), at 50%RH, 23°C |  |  |\n| --- | --- | --- | --- | --- | --- | --- |\n| ANSI/ESD STM4 .1 Test Position | Sample \\#1 | Sample \\#2 | Sample \\#3 | Sample \\#1 | Sample \\#2 | Sample \\#3 |\n| Figure 1 – Position 1 | 1.31 x 107 | 1.18 x 107 | 1.15 x 107 | 2.59 x 106 | 2.83 x 106 | 2.68 x 106 |\n| Figure 1 – Position 2 | 1.24 x 107 | 1.25 x 107 | 1.14 x 107 | 2.52 x 106 | 2.80 x 106 | 2.85 x 106 |\n| Figure 1 – Position 3 | 1.37 x 107 | 1.42 x 107 | 1.27z x 107 | 2.91 x 106 | 2.82 x 106 | 2.83 x 106 |\n| Figure 1 – Position 4 | 1.54 x 107 | 1.50 x 107 | 1.60 x 107 | 3.39 x 106 | 2.78 x 106 | 3.04 x 106 |\n| Figure 1 – Position 5 | 1.27 x 107 | 1.36 x 107 | 1.38 x 107 | 3.14 x 106 | 3.06 x 106 | 3.08 x 106 |\n| Min.= | 1.24 x 107 | 1.18 x 107 | 1.14 x 107 | 2.52 x 106 | 2.78 x 106 | 2.68 x 106 |\n| Mean = | 1.34 x 107 | 1.34 x 107 | 1.30 x 107 | 2.89 x 106 | 2.86 x 106 | 2.89 x 106 |\n| Max. = | 1.54 x 107 | 1.50 x 107 | 1.60 x 107 | 3.39 x 106 | 3.06 x 106 | 3.08 x 106 |\n\nTable 2-Resistance Point-to-Point  \n\n|  | RTT (ohms), at 12%RH, 23°C |  |  | RTT (ohms), at 50%RH, 23°C |  |  |\n| --- | --- | --- | --- | --- | --- | --- |\n| ANSI/ESD STM4 .1 Test Position | Sample \\#1 | Sample \\#2 | Sample \\#3 | Sample \\#1 | Sample \\#2 | Sample \\#3 |\n| Figure 2 – Set up A | 8.97 x 107 | 6.46 x 107 | 4.72 x 107 | 7.60 x 106 | 7.25 x 106 | 8.14 x 106 |\n| Figure 2 – Set up B | 7.98 x 107 | 6.24 x 107 | 5.99 x 107 | 6.77 x 106 | 6.95 x 106 | 7.15 x 106 |\n| Figure 2 – Set up C | 7.77 x 107 | 6.46 x 107 | 5.33 x 107 | 6.81 x 106 | 7.05 x 106 | 7.40 x 106 |\n| Figure 2 – Set up D | 6.91 x 107 | 5.71 x 107 | 4.59 x 107 | 7.55 x 106 | 6.36 x 106 | 6.91 x 106 |\n| Min.= | 6.91 x 107 | 5.71 x 107 | 4.59 x 107 | 6.77 x 106 | 6.36 x 106 | 6.91 x 106 |\n| Mean = | 7.87 x 107 | 6.21 x 107 | 5.13 x 107 | 7.17 x 106 | 6.89 x 106 | 7.39 x 106 |\n| Max. = | 8.97 x 107 | 6.46 x 107 | 5.99 x 107 | 7.60 x 106 | 7.25 x 106 | 8.14 x 106 |\n\nReferences:  \nANSI/ESD STM4.1 – Figure 1: Work-surface – Resistance-to-Groundable Point  \nANSI/ESD STM4.1– Figure 2: Work-surface – Resistance Point-to-Point","cbCaiaUxAHHbQfhF","https://ap.wps.com/l/cbCaiaUxAHHbQfhF","pdf",271505,"English","# Qualification Report – ANSI/ESD S20.20\n## Resistance-to-Groundable point\n## Resistance Point-to-Point\n## References","[{\"question\":\"What standard and product are qualified in this report?\",\"answer\":\"The report qualifies an SCS R3 dissipative rubber mat under ANSI/ESD S20.20.\"},{\"question\":\"How are resistance results measured and under what conditions?\",\"answer\":\"Resistance is measured as resistance to a groundable point and resistance point-to-point after 48–72 hours conditioning at 12% RH and 50% RH (23°C), using 100V and N=3 specimens.\"},{\"question\":\"Which test method and references are used for the data tables?\",\"answer\":\"Test methods reference ANSI/ESD STM4.1, and the figures are identified for work-surface measurements: Figure 1 for resistance-to-groundable point and Figure 2 for resistance point-to-point.\"}]","Qualification Report – ANSI/ESD S20.20 - SCS R3 Dissipative Rubber Mat | PDF"]