[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-201983-105":59,"doc-detail-201983-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","px2ln-stratus-multi-deck-specification-sheet","PX2LN-STRATUS - MULTI-DECK SPECIFICATION SHEET","","PX2LN-STRATUS multi-deck specification sheet (Issue date: September 2018) provides case-by-case performance and engineering data for refrigeration and airflow systems. It lists general case dimensions, display area, cubic capacity, and maximum shelf depth/weight, then details refrigeration discharge conditions, thermal loads for canopy LED configurations, and refrigerant charge estimates for HFC and glycol options. The electrical section summarizes fan and lighting power by voltage and amperage, and the defrost data specifies off-cycle defrost frequency, failsafe duration, termination temperature, and drip time.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/px2ln-stratus-multi-deck-specification-sheet/201983/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/px2ln-stratus-multi-deck-specification-sheet/201983.png","ImageObject",300,407,{"name":92,"@type":93},"Eliana","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-09-19","2026-09-04",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What general case metrics are provided for each case length?","Question",{"text":112,"@type":113},"The sheet lists case length, total display area, cubic capacity, and maximum shelf depth/weight (with top/bottom values).","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What refrigeration performance parameters are included?",{"text":117,"@type":113},"Refrigeration data includes discharge air velocity, fan speed, discharge air temperature, conventional and LED canopy thermal loads, and evaporator temperature with superheat setpoints.",{"name":119,"@type":110,"acceptedAnswer":120},"What defrost and electrical details are specified?",{"text":121,"@type":113},"Defrost data covers defrosts per day, failsafe duration, termination temperature, and drip time, while electrical data provides fan and light power/amperage at 115V/60Hz, 1 phase.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},201983,1788540630,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":24},4398048949847,"https://ap-avatar.wpscdn.com/avatar/400002536579ef2da7f?_k=1778318612642679267","ISSUE DATE: SEPTEMBER 2018  \nPX2LN-STRATUS  \nMULTI-DECK SPECIFICATION SHEET  \nCase Length (ft)  \nGeneral Case Data  \nTotal Display Area (ft2)  \nCubic Capacity (ft3)  \nMax Shelf Depth (in) [Top/Bottom] Weight (lb)  \n4’  \n13.90  \n29.28 20/24  \n-  \n6’  \n20.82  \n43.85 20/24  \n-  \n8’  \n27.77  \n58.50 20/24  \n-  \n12’  \n41.64  \n87.71 20/24  \n-  \nRefrigeration Data (General)  \nDischarge Air Velocity (fpm)  \nFan Speed (rpm)  \nDischarge Air Temp (˚F)  \nConventional Thermal Load, Single (Btuh) one row of canopy LED Parallel Thermal Load, Single (Btuh) one row of canopy LED  \n200-325 1800  \n31  \n5025  \n4652  \n200-325 1800  \n31  \n7537  \n6978  \n200-325 1800  \n31100499303  \n200-325 1800  \n311507413955  \nAdditional Btuh per ft LED-Canopy / Shelf & Nose 13 / 11 13 / 11 13 / 11 13 / 11  \n Refrigeration Data (HFC)   \nEvaporator Temperature (˚F) 23 23 23 23  \nSuperheat Setpoint (˚F) 6-8 6-8 6-8 6-8  \nEstimated Refrigerant Charge (lbs) 1.849 2.765 3.699 5.443  \n Refrigeration Data (Glycol)   \nSupply Temperature (˚F) Flow (GPM)  \nFluid %  \nPressure Drop (PSID)  \n20  \nQTE  \n35  \nQTE  \n20  \nQTE  \n35  \nQTE  \n20  \nQTE  \n35  \nQTE  \n20  \nQTE  \n35  \nQTE  \nElectrical Data (Amps/Watts)  \n115V/60Hz, 1 Phase  \nFans 0.20 0.40 0.40 0.60  \nCanopy Lights (Per row)  \nShelf Lights (Per row)  \nGE  \nGE  \nLED  \nLED  \n0.22  \n0.08  \n0.33  \n0.10  \n0.40  \n0.15  \n0.60  \n0.23  \nAPPLICATIONS  \n|  |  |  |  |  |\n| --- | --- | --- | --- | --- |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n|  |  |  |  |  |\n\n\n| Defrost Data (off Cycle) |  |  |  |\n| --- | --- | --- | --- |\n| Defrosts per Day | Failsafe Duration (min)1 | Termination Temp (˚F) | Drip Time (min) |\n| 6 | 18 | 47 | 2 |\n\n1 At ASHRAE conditions. For conditions above 75°F, 55% RH, increase defrost time by 15 min. Type I refrigerator, intended for use in an area where the environmental conditions are controlled and maintained that conditions do not exceed 75°Fand 55% relative humidity. Kysor Warren, whose policy is one of continuous improvement, reserves the right to change at any time specifications, designs, or prices without incurring obligation. DOE 2017 Compliant  \nPX2LN-STRATUS  \n MULTI-DECK SPECIFICATION SHEET   \nPX2LN CROSS VIEW  \nAdd 3” thickness for a pair of ends .  \nPX2LN PLAN VIEW (SINGLE COIL)","cbCaibLSgWxRvsNg","https://ap.wps.com/l/cbCaibLSgWxRvsNg","pdf",505456,"English","# General Case Data\n## Refrigeration Data (General)\n## Refrigeration Data (HFC)\n## Refrigeration Data (Glycol)\n## Electrical Data\n## Applications\n## Defrost Data (off Cycle)","[{\"question\":\"What general case metrics are provided for each case length?\",\"answer\":\"The sheet lists case length, total display area, cubic capacity, and maximum shelf depth/weight (with top/bottom values).\"},{\"question\":\"What refrigeration performance parameters are included?\",\"answer\":\"Refrigeration data includes discharge air velocity, fan speed, discharge air temperature, conventional and LED canopy thermal loads, and evaporator temperature with superheat setpoints.\"},{\"question\":\"What defrost and electrical details are specified?\",\"answer\":\"Defrost data covers defrosts per day, failsafe duration, termination temperature, and drip time, while electrical data provides fan and light power/amperage at 115V/60Hz, 1 phase.\"}]","PX2LN-STRATUS - MULTI-DECK SPECIFICATION SHEET | PDF"]