[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-detail-217272-en":3,"doc-seo-217272-105":30,"detail-sidebar-cat-0-en-105":91},{"code":4,"msg":5,"data":6},0,"success",{"doc_id":7,"user_id":8,"nickname":9,"user_avatar":10,"doc_module":4,"category_id":11,"category_name":12,"doc_title":13,"doc_description":14,"doc_content":15,"file_id":16,"file_url":17,"file_type":18,"file_size":19,"view_count":20,"is_deleted":4,"is_public":21,"is_downloadable":21,"audit_status":21,"page_count":20,"language":22,"language_code":23,"site_id":24,"html_lang":23,"table_of_contents":25,"faqs":26,"seo_title":27,"seo_description":14,"update_tm":28,"read_time":29},217272,2336475104957,"นรินทร์","https://ap-avatar.wpscdn.com/avatar/22000c4c6bd8a5076e1?x-image-process=image/resize,m_fixed,w_180,h_180&k=1787554080175789136",6,"Technology","PTsb-75D - 75W Triple Output With ATX Function - datasheet","75W Triple Output ATX power supply datasheet for the PTSb-75D series, featuring universal full-range AC input, peak 75W capability for 1 minute, and compact size. Includes short circuit, overload, and over-voltage protections, plus power good and power fail signals. Provides built-in remote ON/OFF control, standby 5V at 0.5A with logic inhibit, and 100% full-load burn-in testing. Lists output rails, regulation, ripple/noise, efficiency, input parameters, environmental limits, safety/withstand ratings, and mechanical dimensions.","75W Triple Output With ATX Function P Ts b-7 5 D series  \nFeatures :  \n Universal AC input / Full range  \n Protections: Short circuit / Overload / Over voltage  \n Peak power capability 75W(1min.)  \n Small and compact size  \n With power good signal output  \n Built-in remote ON-OFF control  \n Standby 5V @0.5A and logic inhibit  \n 100% full load burn-in test  \n Low cost  \n 2 years warranty  \nSPECIFICATION  \n\n| MODEL |  | PTsb-75D |  |  |  |\n| --- | --- | --- | --- | --- | --- |\n|  | OUTPUT NUMBER | CH1 | CH2 | CH3 | SB |\n|  | DC VOLTAGE | 5V | 3.3V | 12V | 5V |\n|  | RATED CURRENT | 6A | 2A | 1.5A | 0.5A |\n|  | CURRENT RANGE | 0. 6A ~ 8A | 0. 3A ~ 3A | 0. 2A ~ 2A | 0. 1A ~ 0. 5A |\n|  | RATED POWER | 57.1W |  |  |  |\n|  | PEAK LOAD(1min.) Note.4 | 75W |  |  |  |\n| OUTPUT | RIPPLE & NOISE (max.) Note.2 | 100mVp-p | 100mVp-p | 200mVp-p | 150mVp-p |\n|  | VOLTAGE ADJ. RANGE | FIXED CH1 |  |  |  |\n|  | VOLTAGE TOLERANCE Note.3 | 5. 0% | 8. 0% | 8. 0% | 5. 0% |\n|  | LINE REGULATION | 1. 0% | 2. 0% | 2. 0% | 1. 0% |\n|  | LOAD REGULATION | 3. 0% | 5. 0% | 5. 0% | 3. 0% |\n|  | SETUP, RISE TIME | 600ms, 20ms/230VAC 600ms, 20ms/115VAC |  |  |  |\n|  | HOLD UP TIME (Typ.) | 80ms/230VAC 14ms/115VAC |  |  |  |\n|  | VOLTAGE RANGE | 90 ~ 264VAC 127 ~ 370VDC |  |  |  |\n|  | FREQUENCY RANGE | 47 ~ 63Hz |  |  |  |\n| INPUT | EFFICIENCY (Typ.) | 72% |  |  |  |\n|  | AC CURRENT (Typ.) | 2A/115VAC 1A/23VAC |  |  |  |\n|  | INRUSH CURRENT (Typ.) | COLD START 20A/115VAC 40A/230VAC |  |  |  |\n|  | LEAKAGE CURRENT | \u003C1mA / 240VAC |  |  |  |\n|  | OVERLOAD | 78 ~ 98W(1min. ) rated output power |  |  |  |\n|  |  | Protection type : Shut down o/p voltage, re-power on to recover |  |  |  |\n| PROTECTION | OVER VOLTAGE | 5. 75VDC ~ 6. 75VDC on CH1 ; 5. 25VDC ~ 6. 25VDC on SB |  |  |  |\n|  |  | Protection type : Shut down o/p voltage, re-power on to recover |  |  |  |\n|  | REMOTE CONTROL(PS) | PS-GND Short: power on ; PS-GND open: power off (only 5VSB output) |  |  |  |\n| FUNCTION | POWER GOOD |  100ms After CH1:+5V Rise to 4 . 5V |  |  |  |\n|  | POWER FAIL |  1ms |  |  |  |\n|  | WORKING TEMP. | -10 ~ +60 (Refer to output load derating curve) |  |  |  |\n|  | WORKING HUMIDITY | 20 ~ 90% RH non-condensing |  |  |  |\n| ENVIRONMENT | STORAGE TEMP., HUMIDITY | -20 ~ +85 , 10 ~ 95% RH |  |  |  |\n|  | TEMP. COEFFICIENT | 0. 05%/ (0 ~ 50 ) ON +5V output |  |  |  |\n|  | VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes |  |  |  |\n|  | SAFETY STANDARDS | Design refer to UL60950, TUV EN60950 |  |  |  |\n| SAFETY & | WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:1 . 5KVAC O/P-FG:0 . 5KVAC |  |  |  |\n| EMC | ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms |  |  |  |\n|  | MTBF | 315Khrs min. MIL-HDBK-217F (25 ) |  |  |  |\n| OTHERS | DIMENSION | 137.5*81.5*42mm (L*W*H) |  |  |  |\n|  | PACKING | 0. 33Kg; 40pcs/14Kg/1 . 24CUFT |  |  |  |\n| NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. |  |  |  |  |\n|  | 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12\" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.\u003Cbr>3. Tolerance : includes set up tolerance, line regulation and load regulation.\u003Cbr>4. 10% Duty cycle maximum within every 10 min. Average output power should not exceed the rated power. |  |  |  |  |\n\nFile Name:PTsb-75D-SPEC 2008-03-25  \n75W Triple Output With ATX Function P Ts b-7 5 D series  \n  Mechanical Specification  Unit:mm  \nAC Input Connector (CN1) : MOLEX 5273-03 or equivalent  \n\n| Pin No. | Assignment | Mating Housing | Terminal |\n| --- | --- | --- | --- |\n| 1 | AC/N | MOLEX 5195\u003Cbr>or equivalent | MOLEX 5194\u003Cbr>or equivalent |\n| 2 | No Pin |  |  |\n| 3 | AC/L |  |  |\n\nDC Output Connector (CN2) : MOLEX 5273-6*2 or equivalent  \n\n| Pin No. | Assignment | Pin No. | Assignment | Pin No. | Assignment |\n| --- | --- | --- | --- | --- | --- |\n| 1 | +12V | 6,7,8,9 | GND | 12 | PG |\n| 2,3 | +5V | 10 | RC |  |  |\n| 4,5 | +3.3V | 11 | 5Vsb |  |","cbCaid0uSMzXNOpf","https://ap.wps.com/l/cbCaid0uSMzXNOpf","pdf",412593,2,1,"English","en",105,"# Features\n# Specifications\n## Output Rails and Limits\n## Input Characteristics\n## Protections and Functions\n## Environment and Safety\n# Mechanical Specification\n## Connectors and Pin Assignments\n## Derating and Ripple","[{\"question\":\"What output rails and ratings are specified for the PTSb-75D?\",\"answer\":\"The PTSb-75D provides triple outputs: 5V (CH1) with rated current 6A, 3.3V (CH2) rated current 2A, and 12V rated configuration with rated current 1.5A, plus standby 5VSB rated 0.5A. It also states peak load capability of 75W for 1 minute.\"},{\"question\":\"What protections and remote control functions does the datasheet mention?\",\"answer\":\"Protections include short circuit, overload, and over-voltage, with a shut down output-voltage behavior and recovery by re-powering. Remote control (PS) uses PS-GND short to power on and PS-GND open to power off (only 5VSB remains available).\"},{\"question\":\"What are the key environmental and safety limits?\",\"answer\":\"Working temperature is -10 to +60°C with reference to output load derating, and operating humidity is 20–90% RH non-condensing. Safety standards reference UL60950 and TUV EN60950, with withstand voltage values listed for I/P-O/P, I/P-FG, and O/P-FG, plus isolation resistance and MTBF.\"}]","PTsb-75D - 75W Triple Output With ATX Function - datasheet | PDF",1788831861,5,{"code":4,"msg":31,"data":32},"ok",{"site_id":24,"language":23,"slug":33,"title":13,"keywords":34,"description":14,"schema_data":35,"social_meta":86,"head_meta":88,"extra_data":90,"updated_unix":28},"ptsb-75d-75w-triple-output-with-atx-function-datasheet","",{"@graph":36,"@context":85},[37,53,68],{"@type":38,"itemListElement":39},"BreadcrumbList",[40,44,47,50],{"item":41,"name":42,"@type":43,"position":21},"https://docshare.wps.com","Home","ListItem",{"item":45,"name":46,"@type":43,"position":20},"https://docshare.wps.com/document/","Document",{"item":48,"name":12,"@type":43,"position":49},"https://docshare.wps.com/document/technology/",3,{"item":51,"name":13,"@type":43,"position":52},"https://docshare.wps.com/document/ptsb-75d-75w-triple-output-with-atx-function-datasheet/217272/",4,{"url":51,"name":13,"@type":54,"author":55,"headline":13,"publisher":57,"fileFormat":60,"inLanguage":23,"description":14,"dateModified":61,"datePublished":62,"encodingFormat":60,"isAccessibleForFree":63,"interactionStatistic":64},"DigitalDocument",{"name":9,"@type":56},"Person",{"url":41,"name":58,"@type":59},"DocShare","Organization","application/pdf","2026-09-11","2026-09-08",true,{"@type":65,"interactionType":66,"userInteractionCount":20},"InteractionCounter",{"@type":67},"ViewAction",{"@type":69,"mainEntity":70},"FAQPage",[71,77,81],{"name":72,"@type":73,"acceptedAnswer":74},"What output rails and ratings are specified for the PTSb-75D?","Question",{"text":75,"@type":76},"The PTSb-75D provides triple outputs: 5V (CH1) with rated current 6A, 3.3V (CH2) rated current 2A, and 12V rated configuration with rated current 1.5A, plus standby 5VSB rated 0.5A. It also states peak load capability of 75W for 1 minute.","Answer",{"name":78,"@type":73,"acceptedAnswer":79},"What protections and remote control functions does the datasheet mention?",{"text":80,"@type":76},"Protections include short circuit, overload, and over-voltage, with a shut down output-voltage behavior and recovery by re-powering. Remote control (PS) uses PS-GND short to power on and PS-GND open to power off (only 5VSB remains available).",{"name":82,"@type":73,"acceptedAnswer":83},"What are the key environmental and safety limits?",{"text":84,"@type":76},"Working temperature is -10 to +60°C with reference to output load derating, and operating humidity is 20–90% RH non-condensing. Safety standards reference UL60950 and TUV EN60950, with withstand voltage values listed for I/P-O/P, I/P-FG, and O/P-FG, plus isolation resistance and MTBF.","https://schema.org",{"og:url":51,"og:type":87,"og:title":13,"og:site_name":58,"og:description":14},"article",{"robots":89,"canonical":51},"index,follow",{"doc_id":7,"site_id":24},{"code":4,"msg":5,"data":92},[93,97,101,105,109,112,117,122,127,130,134],{"id":21,"doc_module":4,"doc_module_name":46,"category_name":94,"show_sort_weight":95,"slug":96},"Story & Novel",90,"story-novel",{"id":20,"doc_module":4,"doc_module_name":46,"category_name":98,"show_sort_weight":99,"slug":100},"Literature",80,"literature",{"id":52,"doc_module":4,"doc_module_name":46,"category_name":102,"show_sort_weight":103,"slug":104},"Exam",70,"exam",{"id":29,"doc_module":4,"doc_module_name":46,"category_name":106,"show_sort_weight":107,"slug":108},"Comic",60,"comic",{"id":11,"doc_module":4,"doc_module_name":46,"category_name":12,"show_sort_weight":110,"slug":111},50,"technology",{"id":113,"doc_module":4,"doc_module_name":46,"category_name":114,"show_sort_weight":115,"slug":116},7,"Healthcare",40,"healthcare",{"id":118,"doc_module":4,"doc_module_name":46,"category_name":119,"show_sort_weight":120,"slug":121},8,"Research & Report",30,"research-report",{"id":123,"doc_module":4,"doc_module_name":46,"category_name":124,"show_sort_weight":125,"slug":126},9,"Religion & Spirituality",20,"religion-spirituality",{"id":125,"doc_module":4,"doc_module_name":46,"category_name":128,"show_sort_weight":125,"slug":129},"World Cup","world-cup",{"id":131,"doc_module":4,"doc_module_name":46,"category_name":132,"show_sort_weight":131,"slug":133},10,"Lifestyle","lifestyle",{"id":135,"doc_module":4,"doc_module_name":46,"category_name":136,"show_sort_weight":29,"slug":137},19,"General","general"]