[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-662775-105":59,"doc-detail-662775-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","progressive-cavity-pump-range-non-binding-operating-and-maintenance-instructions","Progressive Cavity Pump - Range - Non binding Operating and Maintenance Instructions","","Non binding operating and maintenance instructions for the seepex Progressive Cavity Pump range provide an overview of essential safety information and the required procedures for installation, commissioning, operation, and maintenance. The document links the operating instructions to the specific machine using the commission number, identifies the manufacturer and machine details such as range, size, version, and construction year, and explains how modifications are documented through new covers or supplemental sheets. It also includes EEC machine directive compliance notes and a CAUTION requirement to keep the documentation available for at least 10 years.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/progressive-cavity-pump-range-non-binding-operating-and-maintenance-instructions/662775/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/progressive-cavity-pump-range-non-binding-operating-and-maintenance-instructions/662775.png","ImageObject",300,407,{"name":92,"@type":93},"Tirek","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":24},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"How are these operating instructions assigned to a specific seepex pump?","Question",{"text":112,"@type":113},"The Commission Number (comm. no) assigns the operating instructions to a particular seepex machine. They are valid only for the machine whose comm. no matches the cover sheet and associated data sheet, Point 9.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What information about the machines is described in the instructions?",{"text":117,"@type":113},"The instructions state machine details such as range, size, version, machine construction year (from the type plate), and the release date (from the cover sheet). They also explain how modifications update the documentation with a new cover and modification index.",{"name":119,"@type":110,"acceptedAnswer":120},"What does the EEC Machine Directive section require before commissioning?",{"text":121,"@type":113},"Commissioning is forbidden until the entire machine/plant satisfies the EEC requirements for Machines. Safety devices must be installed/mounted first; otherwise, a Declaration of Conformity cannot be issued.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},662775,1793222387,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":24,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},5909896572756,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","Operating and Maintenance Instructions  \nProgressive Cavity Pump  \nRange  \nMD  \nNon binding Operating and Maintenance Instructions  \nseepex operating and maintenance instructions are individually compiled for each pump. These operating instructions are non binding and give only an overview.  \nBinding operating instructions can be requested using the email address [om@seepex.com](om@seepex.com) . For this purpose, please also indicate the relevant pump comm. number.  \nThis operating and maintenance instruction includes important safety information and instructions for installation, commissioning, operating and maintenance of the seepex machinery.  \nIt is essential therefore, that the responsible specialist refers to it before starting any work on the machinery as well as prior to commissioning. Futhermore, this instruction must always be available on site.  \nOperating and Maintenance  \nInstructions  \nProgressive Cavity Pump  \nindex  \nitem document denomination  \n1.0.0 OM.GEN.01e General  \n2.0.0 OM.SAF.01e Safety  \n3.0.0 OM.TRA.01e Transport and Intermediate Storage  \n4.0.0 OM. DES.01e Description of the seepex pump and Accessories  \n5.0.0 OM. INS.01e Assembly and Installation  \n6.0.0 OM.COM.01e Commissioning/De-commissioning  \n7.0.0 Service and Maintenance  \nOM. MAI.40e MD 0015-24 to 012-24 (stainless steel-design)  \nOM. MAI.41e MD 0015-24 to 012-24 (synthetic construction)  \nOM. MAI.42e MD 0015-24 to 012-24 (stainless steel/tie bolt design)  \n7.1.0 Pin Joint Assembly  \nOM. PJT.04e Range MD  \n7.2.0 OM. HBD.01e Holding Band Re-assembly  \n8.0.0 OM. REC.01e Breakdown, reasons, remedies  \n9.0.0 OM.ACC.01e Auxiliary seepex documentation  \nSectional drawing and parts list  \n9.3.0 103-001E2 sectional drawing gland packing (stainless steel-design)  \n9.4.0 SL.103.001 Part List  \n9.3.0 103-003E2 sectional drawing gland packing (synthetic construction)  \n9.4.0 SL.103.003 Part List  \n9.3.0 103-011A2 sectional drawing gland packing (stainless steel/tie bolt design)  \n9.4.0 SL.103.011 Part List  \n9.5.0 Shaft Sealing  \nOM.SEA.Ae Gland packing Code A  \nOM.SEA.01e Gland packing  \nOM.SEA.02e Single acting Mechanical Seal  \n9.6.0 Wearing Parts and Gaskets  \nOM.WPS.40e MD 0015-24 to 012-24 (stainless steel-design)  \nOM.WPS.40e MD 0015-24 to 012-24 (synthetic construction)  \nOM.WPS.42e MD 0015-24 to 012-24 (stainless steel/tie bolt design) OM.SPT.01e Tools  \n10.0.0 OM. MDS.01e Manufacturer's documents from sub-supplier  \n99.0.0 OM.ADR.01e seepex Subsidiaries  \nOperating Instructions seepex Machine General  \nDokument  \ndocument  \nAusgabe issue  \nBlatt sheet  \nOM.GEN.01e  \nA / 10.12.94 1 (2)  \n1.  \nGeneral  \n1.1  \nApplication  \nThese operating instructions contain basic information on the installation, commissioning and maintenance of seepex machines. Compliance with the work steps described in the individual sections is essential.  \n1.2  \nDetails of the seepex machines  \n1.2.1  \nOperating Instructions  \nThe Commission Number ([comm. no](comm. no)) assigns the operating instructions to a particular seepex machine. The operating instructions are produced in relation to a specific job/commission and are valid only for the machine whose [comm. no. is](comm. no. is) identical with that indicated on the cover sheet and possessing the associated data sheet, Point 9.  \n1.2.2  \nManufacturer  \nThe machines were manufactured by seepex.  \n1.2.3  \nRange, Size, Version  \nof the machines are stated in the appended data sheet, Point 9.  \n1.2.4  \nMachine Comm. No. and Year of Construction  \nare stated on the type plate at the machine.  \n1.2.5  \nRelease Date of the Operating Instructions  \nis stated on the cover sheet of the operating instructions.  \n1.2.6  \nModifications, Notes of Modification  \nIf modifications to the machines are  \ncarried out in agreement with seepex, a new set of operating instructions will be provided, or the existing operating instructions will be supplemented by an additional sheet together with a new cover sheet. The date of modification and","cbCaifyXfE08rcXh","https://ap.wps.com/l/cbCaifyXfE08rcXh","pdf",1674578,49,"English","# General\n## Application\n## Details of the seepex machines\n## Manufacturer\n## Range, Size, Version\n## Machine Comm. No. and Year of Construction\n## Release Date of the Operating Instructions\n## Modifications, Notes of Modification\n## EEC Machine Directive\n### Manufacturer's Declaration\n### Declaration of Conformity\n## Copyright and Industrial Property Rights","[{\"question\":\"How are these operating instructions assigned to a specific seepex pump?\",\"answer\":\"The Commission Number (comm. no) assigns the operating instructions to a particular seepex machine. They are valid only for the machine whose comm. no matches the cover sheet and associated data sheet, Point 9.\"},{\"question\":\"What information about the machines is described in the instructions?\",\"answer\":\"The instructions state machine details such as range, size, version, machine construction year (from the type plate), and the release date (from the cover sheet). They also explain how modifications update the documentation with a new cover and modification index.\"},{\"question\":\"What does the EEC Machine Directive section require before commissioning?\",\"answer\":\"Commissioning is forbidden until the entire machine/plant satisfies the EEC requirements for Machines. Safety devices must be installed/mounted first; otherwise, a Declaration of Conformity cannot be issued.\"}]","Progressive Cavity Pump - Range - Non binding Operating and Maintenance Instructions | PDF",123]