[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-292399-105":59,"doc-detail-292399-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","preferred-module-d-plus-node-intron-d-plus-system-features-and-functions","Preferred Module D plus node INTRON-D plus System - Features and Functions","","Preferred Module D plus node expands the INTRON-D plus system with industrial-grade connectivity for digital intercom networks. The solution supports up to 24/96 digital intercom stations, addresses up to 200 IP-based stations, and up to 65,000 stations for speaker circuits. It enables switching of up to 200 simultaneous communication channels, internal audio processing with activation, and Ethernet-based IP system interconnection. Integrated web management simplifies control, while high-capacity controllers interconnect multiple D plus nodes.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/preferred-module-d-plus-node-intron-d-plus-system-features-and-functions/292399/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/preferred-module-d-plus-node-intron-d-plus-system-features-and-functions/292399.png","ImageObject",300,407,{"name":92,"@type":93},"Bulrr","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-21","2026-09-17",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",11,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What capacity does the D plus node support for digital intercom stations and IP-based addressing?","Question",{"text":113,"@type":114},"It supports connection of up to 24/96 digital intercom stations and addressing of up to 200 IP-based intercom stations. It also enables addressing of up to 65,000 stations, speaker circuits, and related endpoints.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How does the system handle audio processing and what is required to activate it?",{"text":118,"@type":114},"An internal audio processing function enables playback of up to 1,000 tones and texts. Activation is required using the specified activation code 101-300-101.",{"name":120,"@type":111,"acceptedAnswer":121},"How can users manage the INTRON-D plus system after installation?",{"text":122,"@type":114},"The integrated web interface allows management using any mainstream web browser, providing straightforward configuration and administration access.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},292399,1789650984,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":24,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":130,"read_time":144},5909892115043,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","Preferred Module D plus Node INTRON-D plus System  \nFeatures and Functions  \n• Connection of up to 24/96 digital intercom stations  \n• Addressing of up to 200 IP-based intercom stations  \n• Addressing of up to 65,000 stations, speaker circuits, etc.  \n• Switching of up to 200 simultaneous communication channels  \n• Internal audio processing function (IAP)  \n• IP-based system interconnection via integrated Ethernet interfaces  \n• LEDs to indicate operation, data transmission and errors  \nPreferred Modules is a special and prioritized INDUSTRONIC product line. These solutions secure the well-known quality of our PA, PA/GA, Intercom and Siren Systems. Especially designed for use in industrial environments, our years of experience have made these modules the number one choice of our Oil & Gas, Chemical & Pharmaceutical, Steel and Power industry customers.  \nOne of our Preferred Module is the D plus node. It is used for carrying out all functions according to the stored configuration file as well as for data exchange between connected digital line cards and terminal devices.  \nAn internal audio processing function (requires activation: 101-300-101) enables the playback of up to 1,000 tonesand texts. There is a memory space of 500 MB for audio files available which can be activated.  \nThe high-capacity controller enables the interconnection of up to 250 INDUSTRONIC D plus nodes. The nodes and IP-based terminal devices can be connected via the integrated Ethernet interfaces (e.g. amplifiers, intercom stations) .  \nThe integrated web interface allows users to easily manage the INTRON-D plus system. Access is possible using any mainstream web browser.  \nThe preferred module is ready for installation straight out of the box – including all necessary accessories, e.g. circuit breakers, a DC/DC converter, relays etc. It can be easily expanded by our various expansion modules  \n(􀃆 Accessoriesˮ, page 3) .  \nModules  \n\n| | Type | PMOD D plus node 01/3RU |\n| --- | --- | --- |\n|  | Description | 19\" sub-rack, 3 RU equipped with:\u003Cbr>1 x 2 DSM 02 system mainboard, DC/DC converter, exchange control board with Ethernet/IP interface for system interconnection, IP terminal equipment connection and integrated webserver, ready for connection with fuses, installation kit, relay, cable feedthrough panel (+ 1 RU) and blank plates |\n|  | Type Number | 325-100-001 |\n|  |  |  |\n| \u003Cbr>Components | Type | PMOD D plus node 01/6RU |\n|  | Description | 19\" sub-rack, 6 RU, equipped with:\u003Cbr>1 x 8 DSM 02 system mainboard, DC/DC converter, exchange control board with Ethernet/IP interface for system interconnection, IP terminal equipment connection and integrated webserver, ready for connection with fuses, installation kit, relay, cable feedthrough panel (+ 1 RU) and blank plates |\n|  | Type Number | 325-100-002 |\n|  |  |  |\n| | Type | 1 DXC 04 |\n|  | Description | Exchange control board with integrated web server for administration |\n|  | Type Number | 341-702-200 |\n|  |  |  |\n\nType  \n10 GW 05  \n\n| Description | DC/DC converter board |\n| --- | --- |\n| Type Number | 309-101-300 |\n\n| | Type | 3 DBT 11 (for module 325-100-001) |\n| --- | --- | --- |\n|  | Description | Mounting rack 19\", 3 RU, for one INTRON-D plus exchange control board , 2 line cards and further boards of 3 RU size |\n|  | Type Number | 216-330-100 |\n|  |  |  |\n| | Type | 7 DBT 13/6 (for module 325-100-002) |\n|  | Description | Mounting rack 19\", 6 RU, for one INTRON-D plus exchange control board , 8 line cards and further boards of 3 RU size |\n|  | Type Number | 216-290-100 |\n|  |  |  |\n| \u003Cbr>Accessories | Description | Mounting and installation instructions |\n|  | Type Number | UMN-325-100-001 |\n|  |  |  |\n\nType  \nPMOD DDL LSZH-FR 01*  \n\n| Description | Line card for up to 12 digital intercom stations |\n| --- | --- |\n| Type Number | 341-799-225 |\n\n*Available as an option if digital intercom stations are required.  \n| |  |  | Type | 03/03 NSG 001* |  |\n| --- | --- | --- | --- | --- | --- |\n|  |  |  |","cbCaieulcKbCICQH","https://ap.wps.com/l/cbCaieulcKbCICQH","pdf",416637,"English","# Features and Functions\n## Preferred Module and D plus node overview\n## Internal audio processing and controller capacity\n## Integrated web interface and ready-to-install scope\n# Modules and Components\n## PMOD D plus node 01/3RU\n## PMOD D plus node 01/6RU\n## Exchange control board and supporting boards\n# Technical Data\n## Mechanical Data\n## Electrical Data\n## Environmental Requirements\n# Standards and Certifications\n# Type Overview and Notes","[{\"question\":\"What capacity does the D plus node support for digital intercom stations and IP-based addressing?\",\"answer\":\"It supports connection of up to 24/96 digital intercom stations and addressing of up to 200 IP-based intercom stations. It also enables addressing of up to 65,000 stations, speaker circuits, and related endpoints.\"},{\"question\":\"How does the system handle audio processing and what is required to activate it?\",\"answer\":\"An internal audio processing function enables playback of up to 1,000 tones and texts. Activation is required using the specified activation code 101-300-101.\"},{\"question\":\"How can users manage the INTRON-D plus system after installation?\",\"answer\":\"The integrated web interface allows management using any mainstream web browser, providing straightforward configuration and administration access.\"}]","Preferred Module D plus node INTRON-D plus System - Features and Functions | PDF",13]