[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-463403-105":59,"doc-detail-463403-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","practical-method-for-evaluating-the-element-sensitivity-variation-of-an-ultrasonic-annular-phased-array-transducer","Practical Method for Evaluating the Element Sensitivity Variation of an Ultrasonic Annular Phased Array Transducer","","Annular phased array transducers employ ring-shaped, concentric elements whose sound field distribution and pulse–echo response differ from conventional linear arrays, making linear-array sensitivity assessment techniques error-prone. This study develops a Rayleigh-integral-based Long-Belt source model to analytically describe ring element responses and links response amplitude to element radial width, validated by numerical simulations. A modified algorithm evaluates element sensitivity using response voltage per unit width to remove geometry-size effects. For a 32-element transducer, maximum sensitivity variation drops from 25 dB to 6 dB, improving measurement reliability while noting the uncorrectable central element limitation.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/practical-method-for-evaluating-the-element-sensitivity-variation-of-an-ultrasonic-annular-phased-array-transducer/463403/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/practical-method-for-evaluating-the-element-sensitivity-variation-of-an-ultrasonic-annular-phased-array-transducer/463403.png","ImageObject",300,407,{"name":92,"@type":93},"Mafia Boss","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-24","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":52},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Why do standard linear-array sensitivity evaluation methods produce errors for annular phased array transducers?","Question",{"text":112,"@type":113},"Annular transducers use ring-shaped, concentric elements that create distinct sound-field distribution and pulse–echo behavior compared with linear arrays. These geometric and acoustic differences can cause significant assessment errors, particularly for element-to-element sensitivity variance.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What theoretical model is used to characterize ring element responses?",{"text":117,"@type":113},"A Long-Belt source assumption model is developed based on the Rayleigh integral. It provides an analytical and explicit characterization of ring-shaped element responses.",{"name":119,"@type":110,"acceptedAnswer":120},"How does the modified sensitivity evaluation algorithm reduce sensitivity variation?",{"text":121,"@type":113},"It uses response voltage per unit width rather than total response voltage, eliminating influences from varying element geometries and sizes. For a 32-element annular array, the maximum sensitivity variation is reduced from 25 dB to 6 dB compared with uncorrected measurements.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},463403,1791171777,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":52,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":46,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":31,"preview_page_count":19,"preview_urls":144},962090760730,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Article  \nPractical Method for Evaluating the Element Sensitivity Variation of an Ultrasonic Annular Phased Array Transducer  \nZhengxiao Sha 1,2,3, *, Xiao Liu 1, Yanze Liu 1, Xiao Wang 1 and Xiaoming Zhou 1  \nAcademic Editor: LucaDeMarchi  \nReceived: 31 October 2025  \nRevised: 9 December 2025  \nAccepted: 17 December 2025  \nPublished: 19 December 2025  \nCopyright: © 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \n1 AECC Beijing Institute of Aeronautical Materials, Beijing 100095, China; [liuxiao621@126.com](liuxiao621@126.com) (X.L.)  \n2 Beijing Key Laboratory of Aeronautical Materials Testing and Evaluation, Beijing 100095, China  \n3 Key Laboratory of Science and Technology on Aeronautical Materials Testing and Evaluation, Aero Engine Corporation of China, Beijing 100095, China  \n* Correspondence: [shazhengxiao@163.com](shazhengxiao@163.com)  \nAbstract  \nThe unique features of annular phased array transducers, such as ring-shaped elements and the concentric configuration, cause them to behave differently from commonly used linear array transducers, in terms of sound field distribution and pulse–echo response. Consequently, standard techniques for assessing linear array transducers can introduce significant errors when applied to annular array transducers, especially concerning element-to-element sensitivity variance. This study investigates the consistency of element sensitivity in annular phased array transducers. Through theoretical analysis, a Long-Belt source assumption model was developed based on the Rayleigh integral to characterize the responses of ringshaped elements in an analytical and explicit form. The model suggests that the response amplitude is linearly correlated with the radial width of the element, which was validated by subsequent numerical simulations. Based on these findings, a modified sensitivity evaluation algorithm for annular array transducers is presented. The response voltage per unit width, rather than the total response voltage, is used to eliminate the influence of varying geometries and sizes across elements. The sensitivity variation of a 32-element annular array transducer was evaluated using the new algorithm. Compared to the uncorrected measurement, the maximum sensitivity variation was reduced significantly from 25 dB to 6 dB, revealing the transducer’s intrinsic consistency despite the different geometric features of each element. Due to its distinct geometry compared to the ring-shaped elements, the central element cannot be corrected or evaluated using this method. These results suggest that the proposed algorithm enables the more accurate evaluation of sensitivity consistency for annular phased array transducers, thereby improving measurement reliability in practical applications.  \nKeywords: annular phased array transducer; Rayleigh integral; sensitivity variation  \n1. Introduction  \nPhased array ultrasonic testing (PAUT) is an advanced non-destructive testing (NDT) method [1] based on the coordinated action of multiple array elements. It achieves the dynamic deflection, focusing, and sweeping of the sound beam by controlling the excitation timing and amplitude of each element. Due to its high resolution, flexibility, and efficiency, PAUT is widely used [2–6] in aerospace, petrochemical, energy, and other industrial fields. The multi-element nature of PAUT enables the acquisition and processing  \nof massive amounts of data simultaneously. Integrating with technologies such as machine learning [7,8] and full matrix capture (FMC) [9] enables more efficient and intelligent non-destructive testing.  \nCompared with linear and rectangular arrays, PAUT based on annular arrays has received less attention. Due to the concentric arrangement of its elements, the annular phased array enables spherical focusing of the sound beam, as opposed to the cylind","cbCairnGYh9cCiX6","https://ap.wps.com/l/cbCairnGYh9cCiX6","pdf",7771377,"English","# Abstract\n# 1. Introduction","[{\"question\":\"Why do standard linear-array sensitivity evaluation methods produce errors for annular phased array transducers?\",\"answer\":\"Annular transducers use ring-shaped, concentric elements that create distinct sound-field distribution and pulse–echo behavior compared with linear arrays. These geometric and acoustic differences can cause significant assessment errors, particularly for element-to-element sensitivity variance.\"},{\"question\":\"What theoretical model is used to characterize ring element responses?\",\"answer\":\"A Long-Belt source assumption model is developed based on the Rayleigh integral. It provides an analytical and explicit characterization of ring-shaped element responses.\"},{\"question\":\"How does the modified sensitivity evaluation algorithm reduce sensitivity variation?\",\"answer\":\"It uses response voltage per unit width rather than total response voltage, eliminating influences from varying element geometries and sizes. For a 32-element annular array, the maximum sensitivity variation is reduced from 25 dB to 6 dB compared with uncorrected measurements.\"}]","Practical Method for Evaluating the Element Sensitivity Variation of an Ultrasonic Annular Phased Array Transducer | PDF",1790766531,[145,149,153,157],{"page_no":8,"url":146,"width":147,"height":148},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/1dd4d18cb5e9f6278a66389f24b5edd6.webp",983,1390,{"page_no":14,"url":150,"width":151,"height":152},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/ebdbe64cd4a8ccd09b1374de0dbe252f.webp",982,1388,{"page_no":81,"url":154,"width":155,"height":156},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/48ecc5c8167f3b84dd1f21fa448c3c6b.webp",981,1387,{"page_no":19,"url":158,"width":159,"height":160},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/7db5810fca4b3cab07759f836deb2201.webp",980,1385]