[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-505363-105":59,"doc-detail-505363-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","pp-ec-02-refrigerant-management-program-policy-and-procedures","PP-EC-02 Refrigerant Management Program - Policy and Procedures","","Policy and Procedures PP-EC-02 for the Iowa Department of Corrections defines requirements for managing refrigerants across use, recovery, recycling, reclamation, storage, and disposal. It establishes controls aligned with the Clean Air Act of 1990, specifies facility roles including designation of a Facility Refrigeration Technician and responsibilities for planning, training, safety, records, and supplier contract oversight. It also outlines key compliance concepts such as the No Vent Law, major and minor leak thresholds, technician and equipment requirements, and core procedures including definitions used throughout the program.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/pp-ec-02-refrigerant-management-program-policy-and-procedures/505363/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/pp-ec-02-refrigerant-management-program-policy-and-procedures/505363.png","ImageObject",300,407,{"name":92,"@type":93},"Aran","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-04","2026-10-04",true,{"@type":102,"interactionType":103,"userInteractionCount":29},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the purpose of Policy PP-EC-02?","Question",{"text":112,"@type":113},"PP-EC-02 describes procedures for general guidance and management of all refrigerant handling within the Iowa Department of Corrections, including controls for use, recovery, recycling, reclamation, and safe storage and disposal.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What does the No Vent Law require and when did it take effect?",{"text":117,"@type":113},"It prohibits knowingly releasing or disposing of Class I or Class II refrigerants in a way that permits entry into the environment during maintenance, service, repair, or disposal. It became unlawful effective July 1, 1992, with additional prohibitions on intentionally venting alternative refrigerants effective November 15, 1995.",{"name":119,"@type":110,"acceptedAnswer":120},"How are major and minor leaks defined in this policy?",{"text":121,"@type":113},"A Major Leak exceeds 15% annual loss, while a Minor Leak does not exceed 15% each year, as referenced in the policy’s definitions section.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},505363,1791240288,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":29,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":19,"preview_urls":146},137455076865,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","State of Iowa Department of Corrections  \nPolicy and Procedures  \nPolicy Number: PP-EC-02  \nApplicability: DOC  \nPolicy Code: Public Access  \nIowa Code Reference: N/A  \nChapter 2: PHYSICAL PLANT  \nSub Chapter: ENVIROMENTAL CONDITIONS  \nRelated DOC Policies: N/A  \nAdministrative Code Reference: N/A  \nSubject: REFRIERANT MANAGEMENT PROGRAM  \nACA Standards: N/A  \nResponsibility: Samantha Tucker, Randy Gibbs  \nEffective Date: February 2023 Authority:  \n1. PURPOSE  \nTo describe procedures required for general guidance and management of all refrigerant handling in the Iowa Department of Corrections (IDOC) .  \n2. POLICY  \nIt is the policy of the IDOC to enact controls during use, recovery, recycling, and reclamation of refrigerants as well as how to safely handle, store, and dispose of those refrigerants. A direct and coordinated management approach is required to support the objective of the Clean Air Act of 1990.  \nCONTENTS  \nA. Facility Refrigerant Manager Designation  \nB. No Vent Law  \nC. Enforcements  \nD. Record Keeping  \nE. Technician Certification and Agreement  \nF. Recovery Equipment  \nG. Equipment Labeling and Storage  \nH. Handling of Refrigerant On-Site  \nI. Refrigerant Contamination  \nJ. Disposal Process  \nK. Refrigerant Safety  \nL. Disposal of Refrigerant Oil  \nM. Overview  \nN. Review  \n3. DEFINITIONS  \nAs used in this document:  \nA. Appliance – Any device that contains and uses a Class I (CFC) or Class II (HCFC) substance as a refrigerant and is used for household or commercial purposes, including any air conditioners, refrigerators, chillers, or freezers.  \nB. De Minimus – The minimum amount of refrigerant released during good faith attempts to recover refrigerant.  \nC. Major Leak – A leak that exceeds 15% annual loss as per Section F. 3. d) of this policy.  \nD. Major Repair – Maintenance, service, or repair that involves the removal of the appliance compressor, condenser, evaporator, or auxiliary heat exchanger coil.  \nE. Minor Leak – A leak rate that does not exceed 15% each year as stated in Section F. 3. d of this policy.  \nF. Opening an Appliance – Any service, maintenance, or repair of an appliance that could reasonably be expected to release refrigerant from the appliance into the atmosphere, unless the refrigerant was previously recovered from the appliance.  \nG. Ozone Depletion Potential – Rating of a chemical’s ability to destroy ozone.  \nH. Reclaim – To reprocess refrigerant to at least the purity specified in the American Refrigeration Institute (ARI) Standard 700-1988, Specifications for Fluorocarbon Refrigerants and to verify this purity as prescribed in the standard. The main difference between recycle and reclaim is that recycle does not involve a chemical analysis of the product. This chemical analysis is only available at a reprocessing or manufacturing facility.  \nI. Recover – To remove refrigerant in any condition from an appliance without necessarily testing or processing it in any way.  \nJ. Recovery Equipment – Two types  \n1. Self-contained (active)– has its own means to draw refrigerant from a refrigeration system  \n2. System dependent (passive)– relies solely upon the compressor in the appliance or the pressure of the refrigerant in the appliance to recover the refrigerant.  \nK. Recycle – To extract refrigerant from an appliance and clean it for reuse without meeting all of the requirements for reclamation. Recycled refrigerant is refrigerant cleaned using oil separation, which reduces moisture, acidity, and/or filtration to remove particulate matter. This is performed on-site.  \nL. Technician – Any person who performs maintenance, service, or repair who could reasonable be expected to release Class I or Class II substances from appliances into the atmosphere, including but not limited to, installers, contract employees, in-house service personnel, and in some cases, owners.  \nM. Venting – Releasing ozone-depleting chemicals into the atmosphere.  \nN. See IDOC Policy AD-GA-16 for additional Defini","cbCaigf887bNaaJT","https://ap.wps.com/l/cbCaigf887bNaaJT","pdf",361484,15,"English","# Purpose\n# Policy\n# Contents\n## Facility Refrigerant Manager Designation\n## No Vent Law\n## Enforcements\n## Record Keeping\n## Technician Certification and Agreement\n## Recovery Equipment\n## Equipment Labeling and Storage\n## Handling of Refrigerant On-Site\n## Refrigerant Contamination\n## Disposal Process\n## Refrigerant Safety\n## Disposal of Refrigerant Oil\n## Review\n# Definitions\n# Procedures\n## Facility Refrigerant Manager Designation\n## No Vent Law\n## Enforcements","[{\"question\":\"What is the purpose of Policy PP-EC-02?\",\"answer\":\"PP-EC-02 describes procedures for general guidance and management of all refrigerant handling within the Iowa Department of Corrections, including controls for use, recovery, recycling, reclamation, and safe storage and disposal.\"},{\"question\":\"What does the No Vent Law require and when did it take effect?\",\"answer\":\"It prohibits knowingly releasing or disposing of Class I or Class II refrigerants in a way that permits entry into the environment during maintenance, service, repair, or disposal. It became unlawful effective July 1, 1992, with additional prohibitions on intentionally venting alternative refrigerants effective November 15, 1995.\"},{\"question\":\"How are major and minor leaks defined in this policy?\",\"answer\":\"A Major Leak exceeds 15% annual loss, while a Minor Leak does not exceed 15% each year, as referenced in the policy’s definitions section.\"}]","PP-EC-02 Refrigerant Management Program - Policy and Procedures | PDF",1791145630,38,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/7eb25f7b7d584222ac6480a78315a17c.webp",983,1272,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/19ef16876c137cb49e9d1fdf5b92094f.webp",982,1270,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/2d20c02bb68aeee3fb3610fa85422a39.webp",981,1269,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/022ec741051e749be517d93fd69c6e19.webp",980,1268]