[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-557996-105":59,"doc-detail-557996-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","power-supply-alimentation-netzteil-alimentazione-alimentacion","POWER SUPPLY - ALIMENTATION - NETZTEIL-ALIMENTAZIONE-ALIMENTACIÓN","","Power supply measurement and safety guidance for primary-side diagnostics: use the primary power unit ground (PGND) during measurements and, when repairing, replace components only with original parts. The content includes board connection notes related to mains supply, standby status references, and detailed schematic-style component listings with designators and electrical values. It also references degaussing-coil connections and provides a part list for tube components and associated ratings and substitutions.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/power-supply-alimentation-netzteil-alimentazione-alimentacion/557996/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/power-supply-alimentation-netzteil-alimentazione-alimentacion/557996.png","ImageObject",300,407,{"name":92,"@type":93},"Patrick","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-22","2026-10-12",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What ground should be used during measurements in the power supply unit?","Question",{"text":112,"@type":113},"Use the primary power unit ground (PGND).","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What should be done when repairing safety-related parts?",{"text":117,"@type":113},"Use original parts only for replacement.",{"name":119,"@type":110,"acceptedAnswer":120},"What connection is referenced for the power supply design?",{"text":121,"@type":113},"The document references a degaussing-coil connection and board sections connected to the mains supply.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},557996,1792667361,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":39,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":46},549758146520,"https://ap-avatar.wpscdn.com/avatar/80002397d8c0411e94?_k=1775819394049821470","POWER SUPPLY - ALIMENTATION - NETZTEIL-ALIMENTAZIONE-ALIMENTACIÓN  \nNote :  \nDuring measurements in the power supply unit  \n-Use the primary power unit ground ( PGND ) .  \nAttention :  \nMesure dans le bloc alimentation  \n-Utiliser la masse du bloc alimentation ( PGND ) .  \nAchtung :  \nBei Messungen im Primärnetzteil  \n- Primärnetzteilmasseverwenden ( PGND ) .  \nAttenzione :  \nmisure nell'alimentatore primario  \n-usare massa alimentazione primario ( PGND ) .  \nCuidado :  \nMedida en el bloque de alimentacion-Utilizar la masa del bloque dealimentacion ( PGND ) .  \nPart of board connected to mains supply. Partie du châssis reliée au secteur. Primärseite des Netzteils.  \nParte dello châssis collegata alla rete. Parte del chassis conectar a la red.  \n-  \n+  \n-  \n+  \nMAIN  \n(PP)  \n17300  \n17304  \n17306  \n17310  \n17314  \n17364  \nBP15  \nP P  \nTo DEGAUSSING-COIL  \nP  \nBP85 EFC  \n+UA 1  \n2  \nBL80 (ONLY SOME MODELS)  \nBP85  \nICC17  \nBL80  \n1 2  \nUA  \nTL81 BC327-40  \nRL81  \n1K8  \nRL80  \n22R0  \nTL80  \nR1LK803 BC337-40  \nDL80 CL80  \nBZX55C27 47U0  \nTL82 BC337-40  \nPL80 47K0  \nTL83 BC327-40  \nRL84 CL82  \n470R0 1MI0  \nRL85  \n5K6  \nDL81  \nBZX55C15  \nRL82 150R0  \nBP01  \nEFC.17000.00 (TUBE 16/9)  \nDL82 1N4148  \nCL83 100N0  \nDL83 1N4148  \nRL86 270R0  \nRL87 270R0  \n2 1  \n2 1  \nBL81  \nBL82  \nEFC  \ncoil  \nHEARTH FIELD CONNECTION COIL  \n(180V-260V)  \nSicherheitsbauteil  \nBei Ersatz nur Originalteil verwenden  \nSafety Part  \nWhen repairing, use original part only Piece de securite  \nN'utilisez que les pieces d'origine  \n(5) : standby  \n1 CP15  \n2 68N0  \nRP15  \n18R0  \nJP15  \n0  \n3  \n1 2  \nRP02  \n1M0  \n0W7  \nCP02 100N0  \nLP01  \n60MI0  \n3 6  \nCP01  \n100N0 FP01  \nT2.5AL  \n2 1  \nN6  \nMainsvoltage 1 4  \nCP17 470N0  \n-  \n275V~  \nPGND  \nCP16 470N0  \n-  \n275V~  \nRP04  \n2R7  \n10W  \nDP17 1N4004GP  \nDP16 1N4004GP  \nCP18 330P0  \nDP18 1N4004GP  \nDP19 1N4004GP  \nRP20 470R0  \n0W25  \nCP21 330P0  \nDP20 BZX55C51  \nCP03  \n4N7  \nDP01 BYW27-1000  \nDP03 BYW27-1000  \nCP05 1N5 PGND  \nDP02 BYW27-1000  \nDP04 BYW27-1000  \nCP04  \n4N7  \nDP21 BZX85C39  \nDP22 BZX55C6V8  \nCP24  \n4U7  \n100V  \nCP26 100U0  \nPGND PGND PGND  \n3,5(3,6)  \nCP23 150P0  \nPGND  \n4,2(6,1)  \nRP26 100K0  \nDP24 LL4148  \nIN-  \n2  \nIN+  \n3  \n8  \n4  \n7(7)  \nV+ OUT  \n1  \nV  \nPGND  \nRP27 100K0  \nRP36 470K0  \nRP30 470K0  \nPGND  \n2,5  \nRP31 270K0  \nIP20  \nTS3702CD 6,8(0)  \nIN-  \n6  \nIN+  \n5  \n8  \n4  \nV+ OUT  \n7 V-  \nPGND  \nRP95 100R0 0W25  \nPGND  \nDP40 LL4148  \nLP06 150U0  \n1  \n6  \n-  \nDP06  \nBZW04-342  \n1  \n2  \n3  \n4  \n5  \n6  \n7  \n8  \n9  \n10  \n11  \n12  \n13  \nSub PFC  \nBP10  \nBP10  \nCP22 100N0  \nRP23 100K0  \nRP24  \n27K0  \n5,4(5,2)  \nRP25 100K0  \nCP35  \n4U7  \nDP39 LL4148  \nRP41 220R0  \nLP09  \n44,8 (44,6)  \nRP21  \n1K0  \nRP22 220R0  \nRP38  \n1K0  \nRP65  \n10K0  \nCP38 100N0  \nTP21  \nBF423  \n46,5(46,2)  \n7,1(6,9)  \nCP20  \n220P0  \n4  \n1  \n3  \n5VPP-H IP50  \nTCET1103G  \nRP17 470K0  \nRP16 470K0  \nRP06 470K0  \nRP01 470K0  \nRP18 470K0  \nRP78  \n470K0  \nPGND  \nPGND  \n297  \n15  \nCP10 CP11  \n150U0 10N0  \n450V 400V  \nPGND PGND  \n16  \n21  \nA1 A2  \n134(154)  \nTP15  \nBTB06-600C  \nRP14  \n1K0  \n1 3G 2  \nTP14 BC546B  \n132(153)  \n131(154)  \nRP13  \n15R0  \nRP08 100R0  \nDP14  \nCP12  \nPGND 100P0  \nRP10  \n2R2  \nRP12  \n270R0  \nRP11 470R0  \nDP12 RGP10G  \nCP13  \n470U0  \n16V  \nBZX55B3V3  \n1000VPP T=12µs  \nCP49  \n3N3  \n1K6V  \nDP50 RGP02-20  \n15VPP T=12µs CP44  \n2N2  \n297(316) 9,2 (0)  \n9,2 (0)  \nRP45  \n10K0  \nDP42 LL4148  \nTP50  \nBUH516TH16  \n-1,1(0,1)  \n-  \n0,2(0)  \n3  \nRP48  \n39R0  \nLP44  \n1 RP40  \n39R0  \nDP47 RGP10G  \nDP48 RGP10G  \n5  \nCP43  \n1N0  \nCP45  \n1N0  \nTP44  \n2SA1020-Y-1,4(0,2)  \nDP46 RGP10G  \nPGND  \nRP46  \n1K5  \nCP47 100N0  \nRP59  \n1K0  \nTP42  \nBC856B  \n8,4(0)  \n9(0)  \nDP44  \nBZX55C3V9  \nRP44  \n820R0  \n0W25  \n3,5(0)  \nTP59 BC846B  \nRP42  \n1K0  \nRP43  \n1K0  \nRP49 470MI0 2W5  \nPGND PGND PGND  \nDP43 RGP02-20 DP45 RGP02-20  \nPGND  \n*  \nCP59 1N5  \n\\# DP84 LP50 RP85 PP 17300 00 MUR120 10537860 XPP 17304 00 MUR420 10590560 -PP 17306 00 MUR120 10537860 XPP 17310 00 MUR120 10687760 XPP 17314 00 MUR420 10687770 -PP 17364 00 MUR420 10590560 -  \nPartlist t","cbCaiojWgwPdATZd","https://ap.wps.com/l/cbCaiojWgwPdATZd","pdf",618534,"English","# POWER SUPPLY - ALIMENTATION - NETZTEIL-ALIMENTAZIONE-ALIMENTACIÓN\n## Measurement ground and safety part notes","[{\"question\":\"What ground should be used during measurements in the power supply unit?\",\"answer\":\"Use the primary power unit ground (PGND).\"},{\"question\":\"What should be done when repairing safety-related parts?\",\"answer\":\"Use original parts only for replacement.\"},{\"question\":\"What connection is referenced for the power supply design?\",\"answer\":\"The document references a degaussing-coil connection and board sections connected to the mains supply.\"}]","POWER SUPPLY - ALIMENTATION - NETZTEIL-ALIMENTAZIONE-ALIMENTACIÓN | PDF",1791799099]