[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-362247-105":59,"doc-detail-362247-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","power-cable-installation-guide-introduction-1","POWER CABLE INSTALLATION GUIDE - Introduction - 01","","Power Cable Installation Guide provides installation information for extruded dielectric power cable systems, covering copper and aluminum conductors from No. 14 AWG through 1000 kcmil and insulation ratings from 600 volts through 35 kilovolts. It emphasizes that installation, design, and use must be handled by competent professionals using currently accepted engineering practices. The guide includes tables, equations, and data for conduit, cable tray, buried earth, aerial, moisture removal, field testing, and related safety and integrity considerations, while disclaiming warranties and liability.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/power-cable-installation-guide-introduction-1/362247/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/power-cable-installation-guide-introduction-1/362247.png","ImageObject",300,407,{"name":92,"@type":93},"LangkahRina","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-19","2026-09-23",true,{"@type":102,"interactionType":103,"userInteractionCount":34},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What cable systems does the guide cover?","Question",{"text":112,"@type":113},"It covers extruded dielectric power cable systems with copper and aluminum conductors from No. 14 AWG through 1000 kcmil, insulated for operation from 600 volts through 35 kilovolts.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Is the guide intended as an authority for design and construction?",{"text":117,"@type":113},"No. It provides general information and is not intended to be or used as authority for design, construction, or use; those activities should be performed by competent professionals using accepted engineering practices.",{"name":119,"@type":110,"acceptedAnswer":120},"What topics are included for installation and testing?",{"text":121,"@type":113},"It includes general field practices, installation in conduit and cable tray, direct burial and aerial installation considerations, field removal of moisture, and field testing methods such as integrity and voltage withstand tests.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},362247,1790436710,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":34,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},962090893776,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","Southwire Company  \nOne Southwire Drive  \nCarrollton, Georgia 30119  \n© 2005 Southwire Company. All rights reserved.  \nPrinted in the United States of America.  \nHypalon is a registered trademark of E.I. DuPont DeNemours & Company. National Electrical Code and NEC are registered trademarks of the  \nNational Fire Protection Association.  \nThis publication is a collection of items of general information related to the subject of power cable. It is not intended to be nor should it be used as authority for design, construction, or use of power cable. The design, construction, and use of power cable should only be undertaken by competent professionals in light of currently accepted design and engineering practices.  \nWhile great care has been employed to ensure that the tables and formulas contained herein are free of errors, absolutely no warranties, either expressed or implied, are made as to the accuracy or completeness of any such tables and formulas contained herein.  \nThose preparing and/or contributing to this publication specifically disclaim any warranty of any kind, either expressed or implied. The warranties of merchantability and fitness for a particular purpose are hereby specifically disclaimed by Southwire and all other parties involved in the creation, production, or delivery of this publication.  \nNeither Southwire nor anyone else who has been involved in the creation, production, or delivery of this publication shall be liable for any direct, indirect, consequential, or incidental damages arising out of the use, the results of the use, or inability to use such publication, even if Southwire has been advised of the possibility of such damages or claim. Some states do not allow the exclusion or limitation for consequential incidental damages, so the above limitation may not apply to you.  \nUSING THIS GUIDE  \nSouthwire Company’s Power Cable Installation Guide provides installation information for extruded dielectric power cable systems. This guide covers copper and aluminum conductors from No. 14 AWG though 1000 kcmil, insulated for operation from 600 volts though 35 kilovolts. Although this guide includes specific recommendations, it is impossible to cover all possible design, installation, and operating situations for every application. Please use the information in this guide as general guidelines only. This guide is intended for users who have an understanding of the engineering fundamentals of power cable systems.  \nThis guide includes many tables, equations, and related data for the convenience of the user. Southwire’s comprehensive Product Catalog provides additional data on cable weights, dimensions, and specifications to be used in concert with this guide. This and other information can be found [at www.southwire.com](at www.southwire.com).  \nThis guide is not a complete representation of the full range of wire and cable products offered by Southwire. For information on any of your wire and cable needs, please contact your local Southwire representative.  \nWe welcome your suggestions so that we can make future editions more relevant, more current, and easier to use.  \nPOWER CABLE  \nINSTALLATION GUIDE  \nIntroduction 01  \nGENERAL FIELD PRACTICES 01   \nIntroduction 01  \nPreplanning 01  \nLow Ambient Temperature 02  \nEquipment 02  \nTraining Radius 04  \nHandling and Storage Guidelines 05  \nDynamometer Corrections 07  \nDiameters of Nonjacketed Cable Assemblies 08  \nPull Boxes 08  \nCable Lubrication Selection 09  \nINSTALLATION IN CONDUIT 10   \nAllowable Tension on Pulling Device 10  \nMaximum Tension on Cable Conductors 10  \nEquations for Pulling Tension 13  \nCoefficient of Friction 14  \nConfiguration 15  \nWeight Correction Factor 15  \nSidewall Pressure 16  \nClearance 17  \nJamming 17  \nConduit Fill 18  \nCalculation Procedure 19  \nINSTALLATION IN CABLE TRAY 20   \nRollers and Sheaves 20  \nPulling Tensions 21  \nCABLES BURIED DIRECTLY IN EARTH 28   \nDepth of Burial 28  \nTrenching 28  \nPlowing 29  \nSupplemental Informatio","cbCaiduAKf87qtt9","https://ap.wps.com/l/cbCaiduAKf87qtt9","pdf",2328078,47,"English","# USING THIS GUIDE\n# POWER CABLE INSTALLATION GUIDE\n## Introduction 01\n## GENERAL FIELD PRACTICES 01\n### Preplanning 01\n### Low Ambient Temperature 02\n### Equipment 02\n### Training Radius 04\n### Handling and Storage Guidelines 05\n### Dynamometer Corrections 07\n### Diameters of Nonjacketed Cable Assemblies 08\n### Pull Boxes 08\n### Cable Lubrication Selection 09\n## INSTALLATION IN CONDUIT 10\n### Allowable Tension on Pulling Device 10\n### Maximum Tension on Cable Conductors 10\n### Equations for Pulling Tension 13\n### Coefficient of Friction 14\n### Configuration 15\n### Weight Correction Factor 15\n### Sidewall Pressure 16\n### Clearance 17\n### Jamming 17\n### Conduit Fill 18\n### Calculation Procedure 19","[{\"question\":\"What cable systems does the guide cover?\",\"answer\":\"It covers extruded dielectric power cable systems with copper and aluminum conductors from No. 14 AWG through 1000 kcmil, insulated for operation from 600 volts through 35 kilovolts.\"},{\"question\":\"Is the guide intended as an authority for design and construction?\",\"answer\":\"No. It provides general information and is not intended to be or used as authority for design, construction, or use; those activities should be performed by competent professionals using accepted engineering practices.\"},{\"question\":\"What topics are included for installation and testing?\",\"answer\":\"It includes general field practices, installation in conduit and cable tray, direct burial and aerial installation considerations, field removal of moisture, and field testing methods such as integrity and voltage withstand tests.\"}]","POWER CABLE INSTALLATION GUIDE - Introduction - 01 | PDF",1790146901,118]