[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-640888-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-640888-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","potterton-profile-30e-40e-50e-60e-80e-installation-and-servicing-instructions","POTTERTON PROFILE 30e, 40e, 50e, 60e, 80e - Installation and Servicing Instructions","","Installation and servicing instructions for Potterton Profile fan powered balanced flue gas-fired boilers covering models 30e, 40e, 50e, 60e and 80e. Provides safety requirements for natural gas (G20) installation by competent persons, certification considerations for approved control devices, and a structured contents overview. Details general operation, suitable indirect hot water use, permissible flue system types and lengths, optional extra kits, recommended compatible controls, and key installation and site requirements including electrical safety considerations for rooms with baths or showers.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/healthcare/","Healthcare",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/potterton-profile-30e-40e-50e-60e-80e-installation-and-servicing-instructions/640888/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/potterton-profile-30e-40e-50e-60e-80e-installation-and-servicing-instructions/640888.png","ImageObject",300,407,{"name":42,"@type":43},"Ophelia","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-07","2026-10-22",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",6,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"Which gas type is the appliance suitable for, and what is the required installer qualification?","Question",{"text":63,"@type":64},"The appliance is for use with natural gas (G20) only. It must be installed and serviced by a competent person as stated in the Gas Safety (Installation and Use) Regulations 1994.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"How should the Potterton Profile boilers be used for hot water and heating?",{"text":68,"@type":64},"The boilers designed to provide domestic hot water and/or central heating must be used on indirect hot water systems only. The cast iron heat exchangers suit open vented gravity systems or fully pumped systems that may be sealed or open vented.",{"name":70,"@type":61,"acceptedAnswer":71},"What flue system options are available and what key height/length limits apply?",{"text":72,"@type":64},"Options include a standard horizontal flue system for wall thickness 100mm to 510mm, a 2 metre horizontal flue system with a maximum flue length of 1955mm, and a vertical flue system terminating at a maximum height of 1980mm from the top of the boiler case.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},640888,1792720148,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,105,109,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":107,"slug":108},7,40,"healthcare",{"id":110,"doc_module":4,"doc_module_name":25,"category_name":111,"show_sort_weight":112,"slug":113},8,"Research & Report",30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":106,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":139,"language":140,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":12,"update_tm":144,"read_time":145,"preview_page_count":4},7971461741311,"https://ap-avatar.wpscdn.com/avatar/74000253aff267980c6?x-image-process=image/resize,m_fixed,w_180,h_180&k=1779345379180704826","| 30e, 40e, 50e, 60e, & 80e, fanned balanced fluegas fired boilers |\n| --- |\n| THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20) ONLY\u003Cbr>\u003Cbr>Installation and Servicing Instructions |\n\nLEAVE THESE INSTRUCTIONS ADJACENT TO THE GAS METER.  \nGAD (90/396/EEC)  \nPOTTERTON PROFILE 30e G.C. No. 41 .605.39  \nPOTTERTON PROFILE 40e G.C. No. 41 .605.40  \nPOTTERTON PROFILE 50e G.C. No. 41 .605.41  \nPOTTERTON PROFILE 60e G.C. No. 41 .605.42  \nPOTTERTON PROFILE 80e G.C. No. 41 .605.43  \nIMPORTANT This appliance must be installed and serviced by a competent person as stated in the Gas Safety (Installation and Use) Regulations 1994.  \nProfile boilers are certified for safety, it is therefore important that no external control devices (e.g. flue dampers, economisers, etc.) be directly connected to these appliances unless covered by these installation instructions or otherwise recommended in writing. Any direct connection of a control device not approved by Potterton could invalidate the certificate and the normal warranty.  \nLIST OF CONTENTS-Page 2  \nGeneral  \nOptional Extras Accessories Installation Data Boiler Dimensions  \nPage No. 2  \nPage No. 2  \nPage No. 3  \nPage No. 3  \nPage No. 3  \nSite Requirements  \nTechnical Data  \nInstallation Instructions Commissioning  \nHealth and Safety Information Control Systems, Pipework and Wiring Guide  \nUser’s Instructions  \nPage No. 3  \nPage No. 6  \nPage No. 11  \nPage No. 18 Back Page  \nSupplied in Literature Pack  \nGENERAL-Page 2  \nPotterton Profile boilers are fully automatically controlled wall mounted fan powered balanced flue appliances, using a cast iron heat exchanger and are available in five outputs ranging from 5.86-23.44kW (20,000-80,000 Btu/h) .  \nThe boilers which are designed to provide domestic hot water and/or central heating must be used on INDIRECT hot water systems only. The cast iron heat exchangers are suitable for use on open vented gravity domestic hot water/pumped central heating systems or fully pumped systems which may be sealed or open vented.  \nAll boilers can be supplied with either of the following types of flue system:  \n1) Standard horizontal flue system suitable for wall thickness of 100mm (4 in.) to 510mm (20 in.) .  \n2) 2 metre horizontal flue system which provides a maximum flue length Of 1955mm (77 in.) .  \n3) Vertical flue system which allows the flue to pass through a flat roof and terminate at a maximum height of 1980mm (78 in.) measured from the top of the boiler case.  \nOPTIONAL EXTRAS-Page 2  \nThe following are kits available as optional extras:—Internal Fitment Kit, which is suitable for a maximum wall thickness of 51 0mm (20 in.) is to be used where access to the outside wall is impracticable.  \nPump Cover Kits, located on top of the boiler and designed to conceal the pump, and/or any motorised valves installed above the boiler. (Note: Pump cannot be fitted above the boiler if the vertical flue kit is used) .  \nTerminal Wall Plate, where necessary can be fitted to the outside wall face to improve the appearance, after making good around the terminal.  \nTerminal Guard, to be used when the terminal is fitted less than 2m above a balcony, above ground or above a flat roof to which people have access.  \nFull fitting instructions are provided with each kit.  \nP. I. L. PART Nos.  \nACCESSORIES-Page 3  \nThe following Potterton Myson controls are recommended for use with your boiler:-  \nElectronic Programmer EP2001, EP3001, or EP6000 Cylinder Thermostat PTT2 or PTT1 00  \nRoom Thermostat PRT2 or PRT1 00  \nFrost Thermostat PRT1 00 FR  \nMotorised Zone Valve M5V222 or M5V228 Motorised Diverter Valve M5V322 Thermostatic Radiator Valve  \nData sheets describing these products are available on request.  \n\n| INSTALLATION DATA-Page 3 |  |  |\n| --- | --- | --- |\n| The installation of the boiler must be in accordance with the | B55440 Part 2 B55449 Part 1 |  |\n| latest relevant requirements of the Gas Safety (Installation and Use) Regulations, local building regulations, lEE Wiring | ","cbCaid4NBMUPFfxu","https://ap.wps.com/l/cbCaid4NBMUPFfxu","pdf",727670,28,"English","# General\n## Optional Extras\n## Accessories\n## Installation Data\n## Boiler Dimensions\n## Site Requirements","[{\"question\":\"Which gas type is the appliance suitable for, and what is the required installer qualification?\",\"answer\":\"The appliance is for use with natural gas (G20) only. It must be installed and serviced by a competent person as stated in the Gas Safety (Installation and Use) Regulations 1994.\"},{\"question\":\"How should the Potterton Profile boilers be used for hot water and heating?\",\"answer\":\"The boilers designed to provide domestic hot water and/or central heating must be used on indirect hot water systems only. The cast iron heat exchangers suit open vented gravity systems or fully pumped systems that may be sealed or open vented.\"},{\"question\":\"What flue system options are available and what key height/length limits apply?\",\"answer\":\"Options include a standard horizontal flue system for wall thickness 100mm to 510mm, a 2 metre horizontal flue system with a maximum flue length of 1955mm, and a vertical flue system terminating at a maximum height of 1980mm from the top of the boiler case.\"}]","POTTERTON PROFILE 30e, 40e, 50e, 60e, 80e - Installation and Servicing Instructions | PDF",1792712044,71]