[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-641389-105":59,"doc-detail-641389-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","pool-only-poolspa-combination-automation-system-installation-operation-manual","POOL ONLY & POOL/SPA COMBINATION AUTOMATION SYSTEM - Installation & Operation Manual","","Installation & operation manual for the JAUTPS/JAUTP Jacuzzi pool automation system, covering pool-only and pool/spa combination configurations. Provides critical safety warnings, installer responsibilities, and guidance on safe electrical installation, including high-voltage wiring, grounding, and connections to relay-controlled equipment. Includes low-voltage wiring for temperature sensors, optional iAquaLink integration, optional Jandy Valve actuator setup, and procedures for system programming, scheduling, unit/language settings, diagnostics, and service mode menu flows.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/pool-only-poolspa-combination-automation-system-installation-operation-manual/641389/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/pool-only-poolspa-combination-automation-system-installation-operation-manual/641389.png","ImageObject",300,407,{"name":92,"@type":93},"Lucas Martin","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-26","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Who must install and service the JAUTPS/JAUTP automation system?","Question",{"text":112,"@type":113},"Installation and servicing must be performed by a contractor licensed and qualified in pool equipment by the jurisdiction where the product is installed. The maintainer must have sufficient experience to follow all instructions exactly.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What safety precautions are emphasized before electrical work?",{"text":117,"@type":113},"All electrical work must be performed by a licensed electrician and conform to applicable national, state, and local codes. Basic safety precautions are required when installing and using the electrical equipment, and safety instructions must be read and followed.",{"name":119,"@type":110,"acceptedAnswer":120},"Which wiring sections cover high-voltage and low-voltage connections?",{"text":121,"@type":113},"High-voltage wiring is covered in the High Voltage Wiring section, including ground fault protection and connecting grounding, transformer, power, and relay-controlled equipment. Low-voltage wiring covers temperature sensors and optional integrations such as iAquaLink and Jandy Valve actuators, where applicable.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},641389,1792860976,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},8796095360427,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","H0682600_REVB  \nINSTALLATION & OPERATION MANUAL  \n| |  |\n| --- | --- |\n|  |  |\n\nPower Alert  \nJAUTPS/JAUTP JACUZZI  \nPOOL ONLY & POOL/ SPA COMBINATION AUTOMATION SYSTEM  \nWARNING  \nFOR YOUR SAFETY -This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the jurisdiction in which the product will be installed where such state or local requirements exist.The maintainer must be a professional with sufficient experience in pool equipment installation and maintenance so that all of the instructions in this manual can be followed exactly. Before installing this product, read and follow all warning notices and instructions that accompany this product. Failure to follow warning notices and instructions may result in property damage, personal injury, or death. Improper installation and/or operation will void the warranty.  \nImproper installation and/or operation can create unwanted electrical hazard which can cause serious injury, property damage, or death.  \nATTENTION INSTALLER-This manual contains important information about the installation, operation and safe use of this product.This information should be given to the owner/operator of this equipment.  \nTABLE OF CONTENTS  \nSection 1. Important Safety Instructions.............3  \nSection 2. System overview ...................................5  \n2.1 Package contents .................................................................. 5  \n2.2 Electrical Specifications ....................................................... 5  \n2.3 Materials and Tools ............................................................... 6  \nSection 3. Install Controller Box ..........................6  \n3.1 Mount the Controller Enclosure ...................................... 6  \nSection 4. High Voltage Wiring...............................7  \n4.1 Ground Fault Circuit Interrupter ..................................... 9  \n4.2 Connect Grounding Wires and Transformer Wires ..... 9  \n4.3 Connect Power and Filter Pump to Relay .................................................................................. 9  \n4.4 Connect Additional Equipment to AUX Relays ....................................................................... 9  \nSection 5. Low Voltage Wiring ........................... 10  \n5.1 Wire the Temperature Sensors ....................................... 10  \n5.2 Install iAquaLink® (if applicable) ...................................... 10  \n5.3 Install Jandy Valve® Actuators (JVAs) (if applicable) ..... 11  \nSection 6. Section System Setup, Programming and Testing.................. 11  \n6.1 Basic Navigation .................................................................. 11  \n6.2 Set the Clock....................................................................... 12  \n6.3 Define Equipment ON/OFF Schedules ..................... 12  \n6.4 Test the JAUTPS/JAUTP.................................................... 13  \nSection 7. Install Settings ..................................... 14  \n7.1 Freeze Protect..................................................................... 14  \n7.2 Units ...................................................................................... 15  \n7.3 Languages.............................................................................. 15  \n7.4 Clear Memory ..................................................................... 16  \n7.5 Pump...................................................................................... 16  \n7.6 Color lights .......................................................................... 17  \n7.7 Label Auxiliary Functions .................................................. 17  \n7.8 Temp Calibrate.................................................................... 17  \n7.9 Solar Priority (if applicable) .............................................. 18  \n7.10 Assign JVA ............................................................................ 18  \n7.11 Assign Hotkeys....................","cbCaidbyzpEFT3Zy","https://ap.wps.com/l/cbCaidbyzpEFT3Zy","pdf",1308247,28,"English","# Section 1. Important Safety Instructions\n# Section 2. System overview\n## 2.1 Package contents\n## 2.2 Electrical Specifications\n## 2.3 Materials and Tools\n# Section 3. Install Controller Box\n## 3.1 Mount the Controller Enclosure\n# Section 4. High Voltage Wiring\n## 4.1 Ground Fault Circuit Interrupter\n## 4.2 Connect Grounding Wires and Transformer Wires\n## 4.3 Connect Power and Filter Pump to Relay\n## 4.4 Connect Additional Equipment to AUX Relays\n# Section 5. Low Voltage Wiring\n## 5.1 Wire the Temperature Sensors\n## 5.2 Install iAquaLink® (if applicable)\n## 5.3 Install Jandy Valve® Actuators (JVAs) (if applicable)\n# Section 6. Section System Setup, Programming and Testing\n## 6.1 Basic Navigation\n## 6.2 Set the Clock\n## 6.3 Define Equipment ON/OFF Schedules\n## 6.4 Test the JAUTPS/JAUTP\n# Section 7. Install Settings\n## 7.1 Freeze Protect\n## 7.2 Units\n## 7.3 Languages\n## 7.4 Clear Memory\n## 7.5 Pump\n## 7.6 Color lights\n## 7.7 Label Auxiliary Functions\n## 7.8 Temp Calibrate\n## 7.9 Solar Priority (if applicable)\n## 7.10 Assign JVA\n## 7.11 Assign Hotkeys\n## 7.12 Ext. SWC Power\n## 7.13 Diagnostics\n# Section 8. Service Mode\n# Section 9. Pool/Spa System Menu Flow Diagrams\n## 9.1 Main Menu\n## 9.2 Install Settings Menu\n# Section 10. Pool Only System Menu Flow Diagrams\n## 10.1 Main Menu\n## 10.2 Install Settings Menu\n# Section 11. Glossaries\n## 11.1 Glossary of Safety Delaysand Lockouts\n## 11.2 Glossary of Alert Messages","[{\"question\":\"Who must install and service the JAUTPS/JAUTP automation system?\",\"answer\":\"Installation and servicing must be performed by a contractor licensed and qualified in pool equipment by the jurisdiction where the product is installed. The maintainer must have sufficient experience to follow all instructions exactly.\"},{\"question\":\"What safety precautions are emphasized before electrical work?\",\"answer\":\"All electrical work must be performed by a licensed electrician and conform to applicable national, state, and local codes. Basic safety precautions are required when installing and using the electrical equipment, and safety instructions must be read and followed.\"},{\"question\":\"Which wiring sections cover high-voltage and low-voltage connections?\",\"answer\":\"High-voltage wiring is covered in the High Voltage Wiring section, including ground fault protection and connecting grounding, transformer, power, and relay-controlled equipment. Low-voltage wiring covers temperature sensors and optional integrations such as iAquaLink and Jandy Valve actuators, where applicable.\"}]","POOL ONLY & POOL/SPA COMBINATION AUTOMATION SYSTEM - Installation & Operation Manual | PDF",1792713851,71]