[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-646747-105":59,"doc-detail-646747-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","pneumatic-blind-rivet-tool-prg-510a-instruction-manual","Pneumatic Blind Rivet Tool - PRG 510A - Instruction Manual","","Instruction manual for the PRG 510A pneumatic blind rivet tool, covering general specifications, compatible nosepiece and mandrel options, recommended lubricants, and operational sequence when the trigger is depressed and released. Includes care and maintenance procedures, recommended cleaning and lubrication intervals, and warnings such as not exceeding specified air pressure. Provides disassembly and assembly guidance, including air piston and seal disassembly steps and caution to shut off the air supply before service.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/pneumatic-blind-rivet-tool-prg-510a-instruction-manual/646747/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/pneumatic-blind-rivet-tool-prg-510a-instruction-manual/646747.png","ImageObject",300,407,{"name":92,"@type":93},"Boyslovefans","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-26","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the maximum air pressure for the PRG 510A tool?","Question",{"text":112,"@type":113},"Do not exceed 85 P.S.I. air pressure, as stated in the specifications with the warning to avoid exceeding this limit.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How should the tool be cared for during regular maintenance?",{"text":117,"@type":113},"Clear spent mandrels, lubricate by dipping the nose housing into Jaw Lube, cycle the tool while immersed, and follow the recommended checks to prevent foreign matter buildup and ensure normal jaw operation.",{"name":119,"@type":110,"acceptedAnswer":120},"What is the basic sequence of events when the trigger is depressed and released?",{"text":121,"@type":113},"When the trigger is squeezed, the valve action sets the piston in motion downward and actuates bell cranks and the pulling head. When released, the valve seals shut off air supply and exhaust occurs, while the piston rod return spring brings components back to normal positions to open jaws and release the spent mandrel.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},646747,1793006039,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":56,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144},1374410101428,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","# INSTRUCTION MANUALPRG 510A\n\nPneumatic Blind Rivet Tool  \nSECTION I—GENERAL INFORMATION  \nThe PRG 510 is a Pneumatic Tool suitable for setting all rivets with a break load up to 1,000 pounds.The PRG 510 isequipped to handle various Nosepieces.See Table 1,Page 2,for specific sizes available.The main castings are made ofhigh tensile aluminum,and replacement parts are interchangeable.  \nPRG 510 WILL SET ONLY THE  \n\n| Table 1  \u003Cbr>NOSEPIECE NUMBERS   |  |  |  |\n| --- | --- | --- | --- |\n|  |  |  |  |\n| RIVET DIA.    |  OPEN END   | CLOSED END  \u003Cbr>5TEEL MANDREL    |  CLOSED END  \u003Cbr>ALUM.MANDREL   |\n| 3/32   | PRN-314   |  |  |\n| 1/8 or 7/64   |  PRN-414   | PRN-424   | PRN-434   |\n| 5/32   | PRN-514   |  | PRN-534   |\n| 3/16   | PRN-614   |  | PRN-634   |\n\n\n| \"POP\"RIVET   |  | S LISTED I   | N THIS   |  CHART   |  |\n| --- | --- | --- | --- | --- | --- |\n| RIVET   | MANDREL    | 7/64  \u003Cbr>3/32二   | 1/8   | 5/32   | 3/16   |\n| O PEN END RIVETS   |  |  |  |  |  |\n| alum.   | alum.   | ●   | ●   |  |  |\n| alum.   | steel   |  |  |  |  |\n| steel   | steel   | ●   | ●   |  |  |\n| monel   | steel   |  | ●   |  |  |\n| stainless   | stainless   |  | ●   |  |  |\n| CLO5ED END RIVET5   |  |  |  |  |  |\n| alum.   | alum.   |  | ●   | ●   |  |\n| alum.   | steel   |  | ●   |  |  |\n\n\n| Table 2   |\n| --- |\n| ACCEPTABLE EQUIVALENTS OF   |\n| RECOMMENDED LUBRICANT,   |\n| LUBRIPLATE 130AA   |\n| ESTAN 1—HUMBLE OIL &REFINING COMPANY   |\n| UNEDO 1—SHELL OIL COMPANY   |\n| SUN C-891T GREASE —SUN OIL COMPANY   |\n| ALASTAC \\#10—TIDEWATER OIL COMPANY   |\n\n\n| DATA   |\n| --- |\n| Weight of Tool………………………   ………4 Ibs.   |\n| Centerline of Nosepiece to Top of Tool……9/16”   |\n| Length Including Deflector ………    ……9Vy₂”   |\n| Length With Deflector Collapsed ……………  …7”   |\n| Length of Stroke ……………………   ………5/8”   |\n| Air Pressure…………85PSL   |\n| (WARNING—Do Not Exceed 85 P.S.I.Air Pressure)   |\n| Air Consumption…     ……………08 CF./Net   |\n\n## SECTION Il\n\nOPERATION  \n4.As this occurs,Jaws PRG 402-8A grip the man-drel of rivet and pull until rivet is set.  \nThe following description gives a brief summary of theevents that occur when the Trigger is depressed.  \n### 1.When Trigger PRG 510-35 is squeezed,Valve Tube\n\n5.When the Trigger is released,the Valve Tube andValve Ring Seal move up,shutting off the air supply.The air then exhausts out through the Valve Tube.  \nPRG 510-37 moves down with Valve Ring Seal PRG  \n510-107,allowing air to flow to top of Piston PRG  \n510-43.  \n2.The air then sets the Piston in motion downward,pull-  \n6.The Piston Rod Return Spring PRG 510-124 returnsthe Piston and the Jaw Guide PRH 820-11A to their nor-mal positions,allowing the Jaws to open and release thespent mandrel.  \ning the Piston Rod PRG 510-41+with t.  \n### 3.This causes the Bell Cranks PRG 510-45 to pivot and\n\nthe Pulling Head PRG 510-48 to move rearward.  \n## SECTION Ⅲl一CARE AND MAINTENANCE\n\na.Clear tool of spent mandrels.  \n### A.GENERAL\n\nb.Dip Nose Housing 11/₂\"into Jaw Lube PRG 510-130  \nFor best results and longer lite a regular service pro-cedure should be established and maintained.  \nc.While immersed,cycle tool several times,pausingbetween cycles.  \nThe following points should be checked on a regularmaintenance basis.  \nd.Remove tool,wipe outer surface clean.  \n1.Under normal working conditions,foreign matterwill accumulate in the Jaw Pulling mechanism andhinder its normal operation.To prevent this build-upand to lubricate the pulling mechanism,the followingprocedure is recommended.NO disassembly of thetoolis required.  \ne.For alternate method,see Section IⅢ A2.Use ONLYrecommended lubricants or equivalent.  \n2.Eventually,dirt build-up may require front end dis-assembly and cleaning.In this event,the following pro-cedure should be followed.  \n)  \na.Disassemble as described in Section IV E1.  \nb.Clean all parts thoroughly including the Nose Hous-ing PRG 510-52A Cavity.Clean serrations in Jaw Teethwith a wire brush if necessary.  \nc.Inspect Jaws and replace if teeth are worn.  \nd.","cbCaij0nUegOrkSV","https://ap.wps.com/l/cbCaij0nUegOrkSV","pdf",774237,"English","# SECTION I—GENERAL INFORMATION\n## OPERATION\n## SECTION III—CARE AND MAINTENANCE\n## SECTION IV—DISASSEMBLY AND ASSEMBLY\n## A.GENERAL\n## B.AIR PISTON AND AIR PISTON SEAL","[{\"question\":\"What is the maximum air pressure for the PRG 510A tool?\",\"answer\":\"Do not exceed 85 P.S.I. air pressure, as stated in the specifications with the warning to avoid exceeding this limit.\"},{\"question\":\"How should the tool be cared for during regular maintenance?\",\"answer\":\"Clear spent mandrels, lubricate by dipping the nose housing into Jaw Lube, cycle the tool while immersed, and follow the recommended checks to prevent foreign matter buildup and ensure normal jaw operation.\"},{\"question\":\"What is the basic sequence of events when the trigger is depressed and released?\",\"answer\":\"When the trigger is squeezed, the valve action sets the piston in motion downward and actuates bell cranks and the pulling head. When released, the valve seals shut off air supply and exhaust occurs, while the piston rod return spring brings components back to normal positions to open jaws and release the spent mandrel.\"}]","Pneumatic Blind Rivet Tool - PRG 510A - Instruction Manual | PDF",1792768334,48]