[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-648775-105":59,"doc-detail-648775-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","plumbing-shop-drawings-approval-request-commercial-buildings-v-10","Plumbing Shop Drawings Approval Request - Commercial Buildings - V 1.0","","Plumbing Shop Drawings Approval Request for commercial buildings, detailing submission requirements for calculations, drawings, and supporting documents. It specifies water supply, sewage, grease interceptors, sand traps, oil interceptors, stormwater, septic tank capacity, and soil infiltration test reporting, with references to Abu Dhabi Uniform Plumbing Code and related tables and sections. It also lists required drawing deliverables in DWF format and highlights applicable Abu Dhabi local regulations and decrees governing design and installation for plumbing networks and drainage systems.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/plumbing-shop-drawings-approval-request-commercial-buildings-v-10/648775/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/plumbing-shop-drawings-approval-request-commercial-buildings-v-10/648775.png","ImageObject",300,407,{"name":92,"@type":93},"How to eat","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-24","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":8},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What calculations must be included with the Plumbing Shop Drawings approval submission?","Question",{"text":112,"@type":113},"Water supply pipe sizing, sewage pipe sizing, grease interceptor sizing (if applicable), sand trap sizing (if applicable), oil interceptor sizing (if applicable), stormwater pipe sizing, septic tank capacity and holding tanks (if applicable), and soil infiltration/absorption area calculations (when a soil absorption system is used).","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which drawing items are required and in what format?",{"text":117,"@type":113},"Gross floor area (GFA) calculation sheets, occupancy classification/use and occupancy load calculations for each space, and sewerage and stormwater layouts and water supply network layouts. These drawings must be submitted in DWF format where specified.",{"name":119,"@type":110,"acceptedAnswer":120},"Which local regulations and codes are referenced to govern the plumbing design and installation?",{"text":121,"@type":113},"The document references Decree no 71 (2014) for application of Abu Dhabi building codes (including ADIBC and AD-UPC) and other decrees for specific installation rules, and requires that sewerage and water supply networks comply with ADIBC Chapter 29 plus AD-UPC, along with the international Plumbing code for missed items.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},648775,1792833051,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":34,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144},962093541613,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Plumbing Shop Drawings Approval Request  \n(Commercial Buildings)  \n1-  Submission requirements:  \n\n| \\# | Type of\u003Cbr>requirement | Description | Drawing | Calculation/\u003Cbr>Model | Form |\n| --- | --- | --- | --- | --- | --- |\n| 01 | Calculations | Water supply pipes’ size calculations to be submitted in accordance with AD-UPC (CH 06-tables 6-7 & 6-9) . |  | 􀀹 |  |\n|  |  | Sewage Pipe size Calculation to be submitted In accordance with ADUPC (CH 07-tables 7-3, 7-4 & 7-7 or Appendix H (Alternative Plumbing systems), table H-3) . |  | 􀀹 |  |\n|  |  | Grease interceptors size calculations (where applicable) to be submitted in accordance with AD-UPC (section 1014-tables 10-2& 10- 3) . |  | 􀀹 |  |\n|  |  | Sand traps size calculations (where applicable) to be submitted in accordance with AD-UPC (section 1016) . |  | 􀀹 |  |\n|  |  | Oil interceptors size calculations (where applicable) to be submitted in accordance with AD-UPC (section 1017) . |  | 􀀹 |  |\n|  |  | Storm water pipes’ sizes calculation to be submitted in accordance with AD-UPC (section 1101.11. & 1106-tables 11-1 & 11-2) . |  | 􀀹 |  |\n|  |  | Septic tank capacity calculation & holding tanks (where applicable) tobe submitted in accordance ADIPSDC-Section 802 & ADIPSDC-section 805-tables 802 .7. 2, 805.2 consecutively. |  | 􀀹 |  |\n|  |  | Soil infiltration test report and absorption area calculation (where soil absorption system is used) to be submitted in accordance with\u003Cbr>ADIPSDC (section 06) . |  | Report􀀹 |  |\n| 02 | Drawings | Gross floor area (GFA) Calculation sheets in DWF format to be submitted. | 􀀹 |  |  |\n|  |  | Occupancy classification, use, and occupancy load calculation for each space in DWF format to be submitted in accordance with ADIBC Chapter 03 and Chapter 10-section 1004. | 􀀹 |  |  |\n|  |  | Sewerage and storm water layouts to be submitted in DWF format in accordance with Decree no 71 issued by the Department of municipal affairs in 2014 – clause 16. | 􀀹 |  |  |\n|  |  | Water supply network’s layouts to be submitted in DWF format in accordance with Decree no 71 issued by the Department of municipal affairs in 2014 – clause 16. | 􀀹 |  |  |\n| 03 | Documents | Engineer registration card issued by department of municipalities and transport for the concerned plumbing engineer to be incorporated in all drawings. | 􀀹 |  |  |\n\n2- Abu Dhabi local regulations:  \n\n| \\# | Regulation Title | Description | Drawing | Calculation/\u003Cbr>Model | Form |\n| --- | --- | --- | --- | --- | --- |\n| 01 | Decree no 71 issued by the Department of municipal affairs in 2014 regarding the application of Abu Dhabi building codes. | The following codes must be applied for the buildings as mentioned in\u003Cbr>clause-01.\u003Cbr>1- Abu Dhabi International Building Code (ADIBC) .\u003Cbr>2- Abu Dhabi International Mechanical Code (ADIMC) .\u003Cbr>3- Abu Dhabi International Energy Conservation Code (ADIECC)\u003Cbr>4- Abu Dhabi International Fuel Gas Code (ADIFGC) .\u003Cbr>5- Abu Dhabi International Property Maintenance Code (ADIPMC) .\u003Cbr>6- Abu Dhabi International Private Sewage Disposal Code (ADIPSDC) . | 􀀹 |  | 􀀹 |\n| 02 | Decree no (182) - 2017 issued by the department of municipal affairs and Transport regarding the executive regulation | In private villas It is allowed to use roof for services installation purposes (Water tanks, AC machines,etc) as long as services height do not exceeding the roof parapet height as mentioned in clause 15-item 02. | 􀀹 |  |  |\n|  |  | In Private villas where service blocks are built on the wall located on the boundary of a shared plot with the neighbor in private villas, roof water must not drain towards the adjacent plot as mentioned in clause 19-item 10. | 􀀹 |  |  |\n|  |  | In residential buildings used for investment purpose It is allowed to use roof for services installation purposes (Water tanks, AC machines,etc) as long as services height do not exceeding the roof parapet height as mentioned in clause 37-item 03. | 􀀹 |  |  |\n|  |  | In Abu Dhabi Commercial buildings It is not al","cbCairLFakWzMlHI","https://ap.wps.com/l/cbCairLFakWzMlHI","pdf",805256,"English","# Submission requirements\n## Calculations\n## Drawings\n## Documents\n# Abu Dhabi local regulations\n## Decree no 71 (2014)\n## Decree no (182) (2017)\n## Decree no (12) (2021)\n# Codes & standards\n## Abu Dhabi International Building Code (ADIBC)","[{\"question\":\"What calculations must be included with the Plumbing Shop Drawings approval submission?\",\"answer\":\"Water supply pipe sizing, sewage pipe sizing, grease interceptor sizing (if applicable), sand trap sizing (if applicable), oil interceptor sizing (if applicable), stormwater pipe sizing, septic tank capacity and holding tanks (if applicable), and soil infiltration/absorption area calculations (when a soil absorption system is used).\"},{\"question\":\"Which drawing items are required and in what format?\",\"answer\":\"Gross floor area (GFA) calculation sheets, occupancy classification/use and occupancy load calculations for each space, and sewerage and stormwater layouts and water supply network layouts. These drawings must be submitted in DWF format where specified.\"},{\"question\":\"Which local regulations and codes are referenced to govern the plumbing design and installation?\",\"answer\":\"The document references Decree no 71 (2014) for application of Abu Dhabi building codes (including ADIBC and AD-UPC) and other decrees for specific installation rules, and requires that sewerage and water supply networks comply with ADIBC Chapter 29 plus AD-UPC, along with the international Plumbing code for missed items.\"}]","Plumbing Shop Drawings Approval Request - Commercial Buildings - V 1.0 | PDF",1792795100,18]