[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-650703-105":59,"doc-detail-650703-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","plumbing-fixture-schedule-sk-1-laboratory-sink-undermount-chemical-resistant-faucet-ada-designplanningconstruction","Plumbing Fixture Schedule - SK-1 Laboratory Sink UnderMount Chemical Resistant Faucet (ADA) - Design/Planning/Construction","","Plumbing fixture and piping legend material defines line types, symbols, abbreviations, and connection conventions used in a laboratory plumbing layout. It includes a fixture size schedule with waste and vent sizes, identifies line categories such as cold/hot water, acid waste, natural gas, and floor drains, and provides detailed fixture SK-1 specifications. General notes cover emergency eyewash equipment, verification of invert locations for acid waste lines before installation, and mandatory coordination with other trades due to extensive above-ceiling services.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/plumbing-fixture-schedule-sk-1-laboratory-sink-undermount-chemical-resistant-faucet-ada-designplanningconstruction/650703/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/plumbing-fixture-schedule-sk-1-laboratory-sink-undermount-chemical-resistant-faucet-ada-designplanningconstruction/650703.png","ImageObject",300,407,{"name":92,"@type":93},"hdkawk","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What does the plumbing legend include?","Question",{"text":112,"@type":113},"It lists plumbing line symbols and descriptions (e.g., cold water, hot water, hot water return, acid waste, natural gas) plus related connection and clearance conventions.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which fixture is specified in the plumbing fixture schedule section?",{"text":117,"@type":113},"The schedule highlights SK-1 as a laboratory sink with an undermount chemical resistant faucet (ADA) and provides details for faucet types, connection sizes, mounting, supplies, drain, and trap.",{"name":119,"@type":110,"acceptedAnswer":120},"What general installation requirements are stated in the notes?",{"text":121,"@type":113},"The notes require confirming/verifying exact locations and actual invert of acid waste lines before installation and mandate coordination with other disciplines due to large quantities of piping and related systems above the ceiling.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},650703,1792839647,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":24,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":143},3985747859855,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","G MK  \n\n| PLUMBING LEGEND   |  |  |  |  |\n| --- | --- | --- | --- | --- |\n| SYMBOL   | DESCRIPTION   |  | |—   | UNION   |\n| ——-—  —   | COLD WATER LINE-(CW)   |  | '   | SFRANER   |\n| ——--——   | HOT WATER LINE -(HW)   |  | 二   | WALL BOX   |\n| —---—   | HOT WATER RECIRCULATING LINE-(HWR)   |  | FCO   | FL00R CLEANOUT   |\n| ——AW——   | ACID WASTE LINE(AW)   |  | co —   | INLINE CLEANOUT   |\n| 一—AV——   | ACID WASTE VENT LINE(AV)   |  | co →   | WAL CLEANOUT   |\n| —G——   | NATURAL GAS LINE(G)   |  | FD   | FL0OR DRAIN   |\n| ——CA——   | COMPRESSED AIR LINE(CA)   |  |  | BALL VALVE   |\n| C02—一   | CARBON DIOXIDE LINE (CA)   |  | 又   | GAS CoCK   |\n| ——DW——   | DEIONIZED WATER LINE(DW)   |  | ——×—   | PRV   |\n| ①   | VACUM LNE OUTLET   |  |  | PUMP   |\n| CA   | COMPRESSED AIR OUTLET   |  |  | BALANCING VALVE   |\n| C⑩2   | COMPRESSED CARBON DIOXIDE OUTLET   |  | ——厂——   | CHECK VALVE   |\n| NG   | NATURAL GAS OUTLET   |  | ++   | DUAL CHECK VALVE   |\n| —   | END CAP   |  | 区区   | DOUBLE CHECK VALVE   |\n|  | PIPE DOWN OR DROP(DN OR DROP)   |  |  | CHECK VALVE   |\n| 0   | PIPE UP   |  |  | POINT OF CONNECTION -NEW TO EXISTNG   |\n|  | PIPE BREAK OR CONTNUATON   |  |  | AREA TO BE DEMOLSHED   |\n| 90   | P-TRAP   |  |  |  |\n\n\n| FIXTURE SIZE SCHEDULE   |  |  |  |  |\n| --- | --- | --- | --- | --- |\n| MARK   | WASTE   | VEN   | Cw   | HW   |\n| wC   | 4”   |  |  |  |\n|  | 2”   | 11/2”   | 1/2”   | 1/2”   |\n|  |  | 11/2”   | 3/4”   |  |\n| SK   | 2”   | 11/2”   | 1/2”   | 1/2”   |\n| MSB   | 3”   | 11/2”   | 3/4”   | 3/4”   |\n| SH   | 2”   | 11/2”   | 1/2”   | 1/2”   |\n| EWC   |  | 11/2”   | 1/2”   |  |\n\nA S S O CIATES,IN C.  \nPLUMBING FIXTURE SCHEDULE  \nSK-1;LABORATORY SINK UNDERMOUNT CHEMICAL RESISTANT FAUCET(ADA)  \nDesign/Planning/Construction  \nTYPF  \n1201 Main Street,Suite 2100  \nA.UNDERMOUNT EPOXY RESIN 24\"x16\"x12”  \nColumbia,S.C.29201  \n2.FAUCETS  \nA.CHICAGO FAUCET 786-GN8BVE7CP TWO HANDLE_MIXING LAB FAUCET,VACUUM BREAKER,AERATOR  \ntel.803-256-0000  \nB.CHICAGO FAUCET 969-217LHCTF SINGLE HANDLE,VACUUM BREAKER SERRATED TIP.(DW)  \nfax 803-255-7243  \n3.CONNECTION  \nA.1/2”CW&HW,1/2”DW 1-1/2”ACID WASTE  \n4.MOUNTING  \nA.COUNTER UNDERMOUNT AS SHOWN ON ARCH DRAWINGS.  \nALL RIGHTS RESERVED.THIS DRAWING AND THE DESIGN SHOWN  \nTHEREON ARE COPYRIGHTED AS PRESCRIBED BY THE LAWS OF  \n5.SUPPLIES  \nTHE UNITED STATES AND ARE THE PROPERTY OF GMK ASSOCIATES  \nA.MCGUIRE 165LK WITH L00SE KEY STOPS.AERATOR TIP  \nB.WRIST BLADE HANDLES  \nARCHITECTURAL DVSION.ANYONE DUPLICATING,REPRODUCING  \nNOTE:USE THESE SIZES FOR FIXTURE  \n6.DRAIN  \nOR CAUSING TO BE REPRODUCED THE WHOLE OR PART OF THESE  \nA.CHARLOTTE PIPE AW-1A ACID WASTE.  \nDRAWINGS OR THE DESIGN THEREON WITHOUT PERMISSION OF THE  \nARCHITECT WILL BE SUBJECT TO LEGAL ACTION.  \nA.ACID WASTE  \nconsultants  \n\n| ABBREVIATIONS*   |  |  |  |\n| --- | --- | --- | --- |\n| ABV  \u003Cbr>AD  \u003Cbr>AFF   | Above  \u003Cbr>Access Door  \u003Cbr>Above Finished Floor   |  | Not in Contract  \u003Cbr>Normally Open   |\n| BFP   | Backflow Preventer   |  | National Pipe Thread   |\n| CI   |  |  |  |\n| COL   |  |  | Over Flow Storm Drain   |\n| CONN   | Connectior   |  | Oyyaen   |\n| CW   | Cold Water   |  | Plumbing Contractor   |\n| DI   | Dionized Water   |  |  |\n| DN   |  |  | Pressure Reducing Valve   |\n| EC   | Electrical   |  | Pounds Per Square Inch   |\n| ELEV   | Elevation   |  |  |\n| ET   | Expansion Tank   |  |  |\n| EWC-\\#   |  |  | Shower   |\n| FD   | Floor Drain   |  |  |\n| FL   |  |  | Stainless Stee   |\n| FT   |  |  | Storm Drain   |\n| GC   |  |  |  |\n| GPH   | Gallons Per Hour   |  | Standard   |\n| GPM   | Gallons Per Minute   |  | Temperature   |\n| HW   | Hot Water   |  | Top of Steel   |\n| HWR   | Hot Water Return   |  | Typical  \u003Cbr>Urinal  \u003Cbr>Vacuum  \u003Cbr>Vacuum Breaker   |\n| IE   |  |  |  |\n|  | Invert Elevation   |  |  |\n| L-\\#   | Lovgtory   |  |  |\n| MA   | Medical Air   |  | Sanitary Vent   |\n| MAX   | Maximum   |  | Vent Thru Roof  \u003Cbr>Sanitary Waste  \u003Cbr>Wall Box  \u003Cbr>Woter Closet  \u003Cbr>Water Tight Sleeve   |\n| MC  \u003Cbr>MIN  \u003Cbr>MPT","cbCaiaCIqziwao61","https://ap.wps.com/l/cbCaiaCIqziwao61","pdf",2479542,"English","# Plumbing Legend\n## Fixture Size Schedule\n# Plumbing Fixture Schedule (SK-1)\n## Faucets\n## Connection\n## Mounting\n## Supplies and Drain\n# Abbreviations\n# Plumbing General Notes","[{\"question\":\"What does the plumbing legend include?\",\"answer\":\"It lists plumbing line symbols and descriptions (e.g., cold water, hot water, hot water return, acid waste, natural gas) plus related connection and clearance conventions.\"},{\"question\":\"Which fixture is specified in the plumbing fixture schedule section?\",\"answer\":\"The schedule highlights SK-1 as a laboratory sink with an undermount chemical resistant faucet (ADA) and provides details for faucet types, connection sizes, mounting, supplies, drain, and trap.\"},{\"question\":\"What general installation requirements are stated in the notes?\",\"answer\":\"The notes require confirming/verifying exact locations and actual invert of acid waste lines before installation and mandate coordination with other disciplines due to large quantities of piping and related systems above the ceiling.\"}]","Plumbing Fixture Schedule - SK-1 Laboratory Sink UnderMount Chemical Resistant Faucet (ADA) - Design/Planning/Construction | PDF",13]