[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-650841-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-650841-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","pln20_047_plans_grading-garage-code-notes-scope-of-work","PLN20_047_Plans_Grading - Garage Code Notes - Scope of Work","","Scope of work and general code notes for a detached garage project totaling 875 sq. ft. on property with an existing single-family home in Los Gatos, California. Applicable standards reference the 2019 California Building, Residential, Plumbing, Mechanical, Electrical, Fire Codes and the 2019 Title 24 Building Energy Standards. Includes standard abbreviations and specific requirements for door separation between house and garage, protection of usable space under stairs, and detailed provisions for handrails and guardrails height, continuity, and clearance, citing relevant CRC sections.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/pln20_047_plans_grading-garage-code-notes-scope-of-work/650841/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/pln20_047_plans_grading-garage-code-notes-scope-of-work/650841.png","ImageObject",300,407,{"name":42,"@type":43},"Cipher","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",5,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"What is the project scope for the property?","Question",{"text":63,"@type":64},"A new 875 sq. ft. detached garage is added to the site with an existing single-family home.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"Which codes are referenced for compliance?",{"text":68,"@type":64},"The document cites the 2019 California Building, Residential, Plumbing, Mechanical, Electrical, and Fire Codes, plus the 2019 Title 24 Building Energy Standards.",{"name":70,"@type":61,"acceptedAnswer":71},"What are the handrail requirements mentioned?",{"text":72,"@type":64},"Handrails must be provided on at least one side of continuous runs with 4 or more risers, with specified height limits and rules for continuity, terminations, and wall clearance.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},650841,1792847900,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,100,105,110,114,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":97,"show_sort_weight":98,"slug":99},"Comic",60,"comic",{"id":101,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},6,"Technology",50,"technology",{"id":106,"doc_module":4,"doc_module_name":25,"category_name":107,"show_sort_weight":108,"slug":109},7,"Healthcare",40,"healthcare",{"id":111,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":112,"slug":113},8,30,"research-report",{"id":115,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},9,"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":55,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":133,"doc_module":4,"category_id":111,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":55,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":80,"read_time":143},687208528416,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","| ARMSTRONG-KIPLINGER RESIDENCE 20490 SANTA CRUZ HWY, LOS GATOS CA 95033 |  |  |  |  |  | SCOPE OF WORK\u003Cbr>A NEW 875 SQ. FT. DETACHED GARAGE ON PROPERTY WITH EXISTING SINGLE FAMILY HOME. |\n| --- | --- | --- | --- | --- | --- | --- |\n|  |  |  |  |  |  |  |\n|  |  |  |  |  |  | APPLICABLE CODES 2019 CALIFORNIA BUILDING CODE\u003Cbr>2019 CALIFORNIA RESIDENTIAL CODE\u003Cbr>2019 CALIFORNIA PLUMBING CODE\u003Cbr>2019 CALIFORNIA MECHANICAL CODE 2019 CALIFORNIA ELECTRICAL CODE\u003Cbr>2019 CALIFORNIA FIRE CODE\u003Cbr>2019 TITLE 24 BUILDING ENERGY STANDARDS |\n|  |  |  |  |  |  |  |\n| STANDARD ABBREVIATIONS\u003Cbr>& and\u003Cbr>@ at\u003Cbr>C. L. centerline\u003Cbr>Ø diameter\u003Cbr>PLT plate\u003Cbr>\\# pound/number\u003Cbr>(E) existing\u003Cbr>(N) new\u003Cbr>AB anchor bolt\u003Cbr>AC asphaltic concrete\u003Cbr>AGG aggregate\u003Cbr>ALT alternate\u003Cbr>ALUM aluminum\u003Cbr>APPROX approximate ARCH architect\u003Cbr>ASB asbestos\u003Cbr>ASPH asphalt\u003Cbr>AVE avenue\u003Cbr>AVG average\u003Cbr>BB bulletinboard\u003Cbr>BD board\u003Cbr>BITUM bituminous\u003Cbr>BLDG building\u003Cbr>BLK block\u003Cbr>BVLD boulevard\u003Cbr>BM benchmark/beam\u003Cbr>CAB cabinet\u003Cbr>CB catch basin/chalkboard\u003Cbr>CEM cement\u003Cbr>CI cast iron\u003Cbr>CJ control joint\u003Cbr>CLG ceiling\u003Cbr>CLKG caulking\u003Cbr>CLR clear\u003Cbr>CNTR counter\u003Cbr>CO cleanout\u003Cbr>COL column\u003Cbr>CONC concrete\u003Cbr>CONN connection\u003Cbr>CONST contruction CONT continuous\u003Cbr>CORR corridor\u003Cbr>CTR center\u003Cbr>CYL cylinder\u003Cbr>DBL double\u003Cbr>DEPT department\u003Cbr>DF Douglas Fir/drinking fountain\u003Cbr>DIA diameter\u003Cbr>DIM dimension\u003Cbr>DISP dispenser DN down\u003Cbr>DS downspout\u003Cbr>DW dishwasher\u003Cbr>DWG drawing\u003Cbr>DWL dowel\u003Cbr>DWR drawer\u003Cbr>EA each\u003Cbr>EJ expansion joint\u003Cbr>EL elevation\u003Cbr>ELEC electrical\u003Cbr>ELEV elevator\u003Cbr>EMER emergency\u003Cbr>ENCL enclosure\u003Cbr>EP electric panelboard\u003Cbr>EQ equal\u003Cbr>EQUIP equipment\u003Cbr>EXIST existing\u003Cbr>EXP exposed\u003Cbr>EXT exterior\u003Cbr>FA fire alarm\u003Cbr>FD floor drain\u003Cbr>FDN foundation\u003Cbr>FE fire extinguisher\u003Cbr>FEC fire extinguisher cabinet\u003Cbr>FHC fire hose cabinet\u003Cbr>FIN finish\u003Cbr>FL floor\u003Cbr>FLASH flashing FLOUR flourescent FOC face of concrete\u003Cbr>FOF face of finish\u003Cbr>FOS face of stud\u003Cbr>FPRF fire proof\u003Cbr>FS full size\u003Cbr>FT foot/feet\u003Cbr>FTG footing\u003Cbr>FURN furnish\u003Cbr>FURR furring\u003Cbr>FUT future\u003Cbr>GA gauge\u003Cbr>GB grab bar\u003Cbr>GALV galvanized\u003Cbr>GL glass\u003Cbr>GRD grade\u003Cbr>GYP gypsum\u003Cbr>HB hose bib\u003Cbr>HC hollow core\u003Cbr>HD hot dipped\u003Cbr>HDWE hardware\u003Cbr>HDWD hardwood\u003Cbr>HM hollow metal\u003Cbr>HORIZ horizontal\u003Cbr>HR hour\u003Cbr>HT height\u003Cbr>HTG heating\u003Cbr>HTR heater\u003Cbr>ID inside diameter\u003Cbr>IN inches\u003Cbr>INT interior\u003Cbr>INSUL insulation\u003Cbr>JAN janitor\u003Cbr>JT joint\u003Cbr>KD kiln dried\u003Cbr>LAB lab\u003Cbr>LAM laminated\u003Cbr>LAV lavatory\u003Cbr>MAT material\u003Cbr>MAX maximum\u003Cbr>MC medicine cabinet\u003Cbr>MDF medium density fiberboard\u003Cbr>MECH mechanical\u003Cbr>MEMB membrane\u003Cbr>MET metal\u003Cbr>MFGR manufacture(r)\u003Cbr>MH manhole\u003Cbr>MIN minimum\u003Cbr>MIR mirror\u003Cbr>MISC miscellaneous\u003Cbr>MO masonry opening\u003Cbr>MOD module/modular\u003Cbr>MTD mounted\u003Cbr>MUL mullion\u003Cbr>NIC not in contract\u003Cbr>NO number\u003Cbr>NOM nominal\u003Cbr>NTS not to scale\u003Cbr>OC on center\u003Cbr>OD outside diameter\u003Cbr>OFF office\u003Cbr>OPNG opening\u003Cbr>OPP opposite\u003Cbr>PART partition\u003Cbr>PBO provided/supplied by owner\u003Cbr>PERP perpendicular\u003Cbr>PG plate glass\u003Cbr>PL property line\u003Cbr>PLYWD plywood PR pair\u003Cbr>PT pressure treated\u003Cbr>QT quarry tile\u003Cbr>R rise/radius\u003Cbr>RD roof drain\u003Cbr>REINF reiforce/reinforcing\u003Cbr>REF reference\u003Cbr>REFR refridgerator\u003Cbr>REQ required\u003Cbr>RESIL resiliant\u003Cbr>REV revision\u003Cbr>RM room\u003Cbr>RO rough opening\u003Cbr>RWD redwood\u003Cbr>RWL rain water leader\u003Cbr>SECT section\u003Cbr>SEL select\u003Cbr>SD soap dispenser\u003Cbr>SG sheet glass\u003Cbr>SH shelf\u003Cbr>SHT sheet\u003Cbr>SHWR shower\u003Cbr>SIM similar\u003Cbr>SND sanitary napkin dispenser\u003Cbr>SNR sanitary napkin recepticle\u003Cbr>SPEC specification\u003Cbr>SQ square\u003Cbr>SS stainless steel\u003Cbr>SSK service sink\u003Cbr>STD standard\u003Cbr>STL steel\u003Cbr>STRUCT structural SUSP suspend(ed)\u003Cbr>SYM symetrical\u003Cbr>TB towel bar\u003Cbr>TEL telephone\u003Cbr>TER terazzo\u003Cbr>T&G toungue & groove\u003Cbr>TOC top of curb\u003Cbr>TOP top of plate\u003Cbr>TP top of pavement\u003Cbr>TPD toilet paper\u003Cbr>dispenser\u003Cbr>TPG tempered plate\u003Cbr>glass\u003Cbr>TPH toilet paper holder\u003Cbr>TSCH toilet seat cover\u003Cbr>dispens","cbCaiv9SR2LNtA2l","https://ap.wps.com/l/cbCaiv9SR2LNtA2l","pdf",1513494,"English","# Scope of Work\n## Applicable Codes\n## Standard Abbreviations\n## General Code Notes","[{\"question\":\"What is the project scope for the property?\",\"answer\":\"A new 875 sq. ft. detached garage is added to the site with an existing single-family home.\"},{\"question\":\"Which codes are referenced for compliance?\",\"answer\":\"The document cites the 2019 California Building, Residential, Plumbing, Mechanical, Electrical, and Fire Codes, plus the 2019 Title 24 Building Energy Standards.\"},{\"question\":\"What are the handrail requirements mentioned?\",\"answer\":\"Handrails must be provided on at least one side of continuous runs with 4 or more risers, with specified height limits and rules for continuity, terminations, and wall clearance.\"}]","PLN20_047_Plans_Grading - Garage Code Notes - Scope of Work | PDF",13]