[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-646496-105":59,"doc-detail-646496-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","platinum-series-users-guide-introduction-1-introduction","PLATINUM™ Series User’s Guide - Introduction - 1. Introduction","","PLATINUM™ Series process measurement controller documentation covering setup-focused overview and core configuration capabilities. It explains flexible input selection across thermocouples, RTDs, thermistors, and scalable bidirectional DC voltage/current, plus PID, on/off, and heat/cool strategies with autotune and fuzzy adaptive tuning. Control programming supports ramp and soak segments and multiple alarms, alongside configurable outputs, USB updates, and optional network/serial communications. Safety considerations address panel-mount installation, disconnect requirements, overcurrent protection, electrical shock and environmental restrictions, and EMC cabling practices.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/platinum-series-users-guide-introduction-1-introduction/646496/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/platinum-series-users-guide-introduction-1-introduction/646496.png","ImageObject",300,407,{"name":92,"@type":93},"McGucket","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-27","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What input types can the PLATINUM™ Series controller accept?","Question",{"text":112,"@type":113},"The controller supports multiple thermocouple types (including J, K, T, E, R, S, B, C, and N), Pt RTDs (100, 500, or 1000 Ω with specified curves), thermistors (2250 Ω, 5K Ω, and 10K Ω), and DC voltage or DC current.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How is control performed on the PLATINUM™ Series controller?",{"text":117,"@type":113},"Control can use PID, on/off, or heat/cool strategies. PID tuning may use an autotune feature and a fuzzy logic Adaptive Tuning Mode to continuously optimize the PID algorithm.",{"name":119,"@type":110,"acceptedAnswer":120},"What safety and EMC practices are required before installation?",{"text":121,"@type":113},"The manual requires reading it before commissioning, installing a disconnecting external switch or circuit-breaker without using it in the main supply cord, adding overcurrent protection, and following restrictions on wiring, power removal before changes, and operating environment. For EMC, it advises using shielded cables, not running signal and power wires in the same conduit, and using twisted-pair signal wiring connections.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},646496,1793104227,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":36},1236954412713,"https://us-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","For complete product manual:  \n[www.omega.com/manuals/manualpdf/M5451.pdf](www.omega.com/manuals/manualpdf/M5451.pdf)  \nCN32Pt, CN16Pt, CN16DPt, CN8Pt, CN8DPt  \nTemperature & Process Controllers  \nThe information contained in this document is believed tobe correct, but OMEGA accepts no liability for any errors it contains, and reserves the right to alter specifications without notice.  \nOMEGA’s policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 2015 OMEGA ENGINEERING, INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.  \nMQS5451/0117  \nPLATINUMTM Series User’s Guide Introduction  2   \n1. Introduction  \nThe PLATINUMTM Series controller offers unparalleled flexibility in process measurement. While the controller is extremely powerful and versatile, great care has gone into designing a product that is easy to set up and use. Automatic hardware configuration recognition eliminates the need for jumpers and allows the unit’s firmware to automatically simplify itself, eliminating all menu options that do not apply to your configuration.  \nEach unit allows the user to select the input type from 9 thermocouple types (J, K, T, E, R, S, B, C, and N), Pt RTDs (100, 500, or 1000 Ω, with a 385, 392, or 3916 curve), thermistors (2250 Ω, 5K Ω, and 10K Ω), DC voltage, or DC current. The analog voltage inputs are bidirectional and both voltage and current are fully scalable to virtually all engineering units with a selectable decimal point that is perfect for use with pressure, flow, or other process inputs.  \nControl is achieved using the PID, on/off, or heat/cool control strategy. PID control can be optimized with an autotune feature; and in addition, a fuzzy logic Adaptive Tuning Mode allows the PID algorithm to be continuously optimized. The instrument offers up to 16 Ramp and Soak segments per Ramp and Soak program (eight each), with auxiliary event actions available with each segment. Up to 99 Ramp and Soak programs can be stored, and multiple Ramp and Soak programs can be chained, creating unmatched ramp and soak programming capability. Multiple Alarms can be configured for above, below, hi/lo, and band triggering using either absolute or deviation Alarm trigger points.  \nThe PLATINUMTM Series controller features a large, three-color, programmable display with the capability to change color every time the Alarm is triggered. Various configurations of mechanical relay, SSR, DC pulse, and analog voltage or current outputs are available. Every unit comes standard with USB communications for firmware updates, configuration management, and data transfer. Optional Ethernet and RS-232 / RS-485 Serial communications are also available. The Analog Output is fully scalable and may be configured as a proportional controller or retransmission to follow your display. The universal power supply accepts 90–240 Vac. The low-voltage power option accepts 24 Vac or 12–36 Vdc.  \nAdditional features usually found only on more expensive controllers make these the most powerful products in their class. Some additional standard features are remote Setpoint for cascaded control setups, High-high/Low-low Alarm functionality, external latch reset, external Ramp and Soak program initiation, combination Heat/Cool Control Mode, configuration save and transfer, and configuration password protection.  \nPLATINUMTM Series User’s Guide Safety Considerations  3   \n2. Safety Considerations  \nThis device is marked with the international caution symbol. It is important to read this manual before installing or commissioning this device as it contains important information relating to Safety and EMC (Electromagnetic ","cbCaijdGfr8K1Ptv","https://ap.wps.com/l/cbCaijdGfr8K1Ptv","pdf",1092167,16,"English","# 1. Introduction\n# 2. Safety Considerations\n## EMC Considerations","[{\"question\":\"What input types can the PLATINUM™ Series controller accept?\",\"answer\":\"The controller supports multiple thermocouple types (including J, K, T, E, R, S, B, C, and N), Pt RTDs (100, 500, or 1000 Ω with specified curves), thermistors (2250 Ω, 5K Ω, and 10K Ω), and DC voltage or DC current.\"},{\"question\":\"How is control performed on the PLATINUM™ Series controller?\",\"answer\":\"Control can use PID, on/off, or heat/cool strategies. PID tuning may use an autotune feature and a fuzzy logic Adaptive Tuning Mode to continuously optimize the PID algorithm.\"},{\"question\":\"What safety and EMC practices are required before installation?\",\"answer\":\"The manual requires reading it before commissioning, installing a disconnecting external switch or circuit-breaker without using it in the main supply cord, adding overcurrent protection, and following restrictions on wiring, power removal before changes, and operating environment. For EMC, it advises using shielded cables, not running signal and power wires in the same conduit, and using twisted-pair signal wiring connections.\"}]","PLATINUM™ Series User’s Guide - Introduction - 1. Introduction | PDF",1792762976]