[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-640276-105":59,"doc-detail-640276-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","plasma-cutter-owners-manual-air-plasma-cutting-airforce-12ci-and-xt12r-torch","Plasma Cutter Owner’s Manual - Air Plasma Cutting - AirForce 12ci And XT12R Torch","","Owner’s manual for an Air Plasma Cutter system covering AirForce 12ci and XT12R torch use for air plasma cutting. Includes safety precautions and hazard information before operation, installation and maintenance guidance, definitions used on the nameplate and rating label, and detailed specifications such as serial number location, duty cycle, environmental requirements, torch dimensions and weight. Provides step-by-step installation, operating controls and cutting sequences, recommended cutting speed, piercing and stand-off procedures, plus maintenance and troubleshooting instructions.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/plasma-cutter-owners-manual-air-plasma-cutting-airforce-12ci-and-xt12r-torch/640276/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/plasma-cutter-owners-manual-air-plasma-cutting-airforce-12ci-and-xt12r-torch/640276.png","ImageObject",300,407,{"name":92,"@type":93},"Muffet","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-26","2026-10-22",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What safety precautions should be read before using the air plasma cutter?","Question",{"text":112,"@type":113},"Review Section 1 safety precautions, including symbol usage, plasma arc cutting hazards, additional installation/operation/maintenance symbols, California Proposition 65 warnings, principal safety standards, and EMF information.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Where are the serial number and rating label located?",{"text":117,"@type":113},"Section 4 includes “Serial Number And Rating Label Location,” along with specifications for the power source and torch, duty cycle and overheating guidance, and environmental specifications.",{"name":119,"@type":110,"acceptedAnswer":120},"What steps are covered for installation and operation?",{"text":121,"@type":113},"Installation guidance covers selecting a location, connecting the work clamp, electrical service and extension cord data, connecting 115V input power, and generator/inverter requirements. Operation includes controls, recommended cutting speed by material thickness, trigger safety lock, and sequences for cutting, stand-off cutting, and piercing.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},640276,1793051612,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},962090768927,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","OM-272 180B 2015−07  \nProcesses  \n Air Plasma Cutting  \nDescription  \nAir Plasma Cutter  \nAirForce™ 12ci And XT12R Torch  \nFile: Plasma Cutters   \n[www.HobartWelders.com](www.HobartWelders.com)  \nFrom Hobart to You  \nThankyou and congratulations on choosing Hobart. Now you can get the job done and get it done right. We know you don’t have time to do it anyother way.  \nThis Owner’s Manual is designed to help you get the most out of your Hobart products. Please take time to read the Safety precautions. They will help you protect yourself against potential hazards on the worksite.  \nHobart is registered to the ISO 9001 Quality System Standard.  \nWe’ve made installation and operation quick and easy. With Hobart you can count on years of reliable service with proper maintenance. And if for some reason the unit needs repair, there’s a Troubleshooting section that will help you figure out what the problem is. The parts list will then help you to decide the exact part you may need to fix the problem. Warranty and service information for your particular model are also provided.  \nHobart Welders manufactures a full line of welders and welding related equipment.  \nFor information on other quality Hobart products, contact your local Hobart distributor to receive the latest full line catalog or individual specification sheets.  \nTo locate your nearest distributor or service agency call 1-877-Hobart1 or [visit our website at www.HobartWelders.com](visit our website at www.HobartWelders.com).  \nFor Technical Help call 1-800-332-3281.  \nHob_Thank 2009−09  \nWorking as hard as you do − every power source from Hobart is backed by the best warranty in the business.  \nProtect Your Investment!  \nRegister your product at:  \n[HobartWelders.com](HobartWelders.com)  \nTABLE OF CONTENTS  \nSECTION 1 − SAFETY PRECAUTIONS-READ BEFORE USING ................................ 1  \n1-1. Symbol Usage ................................................................. 1  \n1-2. Plasma Arc Cutting Hazards ...................................................... 1  \n1-3. Additional Symbols For Installation, Operation, And Maintenance ....................... 3  \n1-4. California Proposition 65 Warnings ................................................. 4  \n1-5. Principal Safety Standards ....................................................... 4  \n1-6. EMF Information ................................................................ 4  \nSECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION ......................... 5  \n2-1. Signification des symboles ....................................................... 5  \n2-2. Dangers liés au coupage à l’arc au plasma .......................................... 5  \n2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance 7  \n2-4. Proposition californienne 65 Avertissements ......................................... 9  \n2-5. Principales normes de sécurité .................................................... 9  \n2-6. Informations relatives aux CEM ................................................... 9  \nSECTION 3 − DEFINITIONS .................................................................. 10  \n3-1. Symbols And Definitions For Nameplate And Serial Number/Rating Label ................ 10  \nSECTION 4 − SPECIFICATIONS .............................................................. 11  \n4-1. Serial Number And Rating Label Location ........................................... 11  \n4-2. Specifications For Power Source .................................................. 11  \n4-3. Specifications For Torch ......................................................... 11  \n4-4. Duty Cycle And Overheating ...................................................... 11  \n4-5. Selecting A Location ............................................................. 12  \n4-6. Torch Dimensions And Weight .................................................... 12  \n4-7. Environmental Specifications ....................................","cbCairsXVryzWBrR","https://ap.wps.com/l/cbCairsXVryzWBrR","pdf",1322390,36,"English","# SECTION 1 - SAFETY PRECAUTIONS-READ BEFORE USING\n## 1-1. Symbol Usage\n## 1-2. Plasma Arc Cutting Hazards\n## 1-3. Additional Symbols For Installation, Operation, And Maintenance\n## 1-4. California Proposition 65 Warnings\n## 1-5. Principal Safety Standards\n## 1-6. EMF Information\n# SECTION 2 - CONSIGNES DE SÉCURITÉ - LIRE AVANT UTILISATION\n## 2-1. Signification des symboles\n## 2-2. Dangers liés au coupage à l’arc au plasma\n## 2-3. Dangers supplémentaires en relation avec l’installation, le fonctionnement et la maintenance\n## 2-4. Proposition californienne 65 Avertissements\n## 2-5. Principales normes de sécurité\n## 2-6. Informations relatives aux CEM\n# SECTION 3 - DEFINITIONS\n## 3-1. Symbols And Definitions For Nameplate And Serial Number/Rating Label\n# SECTION 4 - SPECIFICATIONS\n## 4-1. Serial Number And Rating Label Location\n## 4-2. Specifications For Power Source\n## 4-3. Specifications For Torch\n## 4-4. Duty Cycle And Overheating\n## 4-5. Selecting A Location\n## 4-6. Torch Dimensions And Weight\n## 4-7. Environmental Specifications\n# SECTION 5 - INSTALLATION\n## 5-1. Selecting A Location\n## 5-2. Connecting Work Clamp\n## 5-3. Electrical Service Guide\n## 5-4. Extension Cord Data\n## 5-5. Connecting 115 Volt Input Power\n## 5-6. Generator Or Inverter Requirements\n# SECTION 6 - OPERATION\n## 6-1. Controls\n## 6-2. Recommended Cutting Speed For Material Thickness\n## 6-3. Trigger Safety Lock\n## 6-4. Plasma Cutting System Practices\n## 6-5. Sequence Of Cutting Operation\n## 6-6. Sequence Of Cutting Using Stand-off Guide\n## 6-7. Sequence Of Piercing Operation\n# SECTION 7 - MAINTENANCE & TROUBLESHOOTING\n## 7-1. Routine Maintenance\n## 7-2. Trouble Lights And Checking Shield Cup Shutdown System\n## 7-3. Checking/Replacing Retaining Cup, Tip, And Electrode\n## 7-4. Compressor Filter Cleaning And Replacement\n## 7-5. Torch And Work Cable Connections\n## 7-6. Troubleshooting Power Source","[{\"question\":\"What safety precautions should be read before using the air plasma cutter?\",\"answer\":\"Review Section 1 safety precautions, including symbol usage, plasma arc cutting hazards, additional installation/operation/maintenance symbols, California Proposition 65 warnings, principal safety standards, and EMF information.\"},{\"question\":\"Where are the serial number and rating label located?\",\"answer\":\"Section 4 includes “Serial Number And Rating Label Location,” along with specifications for the power source and torch, duty cycle and overheating guidance, and environmental specifications.\"},{\"question\":\"What steps are covered for installation and operation?\",\"answer\":\"Installation guidance covers selecting a location, connecting the work clamp, electrical service and extension cord data, connecting 115V input power, and generator/inverter requirements. Operation includes controls, recommended cutting speed by material thickness, trigger safety lock, and sequences for cutting, stand-off cutting, and piercing.\"}]","Plasma Cutter Owner’s Manual - Air Plasma Cutting - AirForce 12ci And XT12R Torch | PDF",1792708328,91]