[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-366034-105":59,"doc-detail-366034-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","photonic-crystal-biosensor-featuring-an-eye-shaped-cavity-for-precise-identification-of-cancerous-cells","Photonic crystal biosensor featuring an eye-shaped cavity for precise identification of cancerous cells","","Highly sensitive and thermally stable photonic crystal (PhC) biosensing technology is developed for accurate cancer-cell detection. The sensor uses a square lattice of silicon rods with a photonic bandgap covering 1.2–2.1 µm, two line-defect waveguides for input/output, and an engineered Eye-shaped cavity that embeds analyte rods at the boundary and central iris-like region. Resonance wavelength shifts driven by refractive-index changes enable label-free detection, with strong transmission efficiency, high sensitivity, and sharp quality-factor peaks. Performance remains stable from 25 °C to 75 °C.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/photonic-crystal-biosensor-featuring-an-eye-shaped-cavity-for-precise-identification-of-cancerous-cells/366034/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/photonic-crystal-biosensor-featuring-an-eye-shaped-cavity-for-precise-identification-of-cancerous-cells/366034.png","ImageObject",300,407,{"name":92,"@type":93},"Aditya","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-29","2026-09-23",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",18,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"How does the eye-shaped cavity improve cancer-cell identification?","Question",{"text":113,"@type":114},"The Eye-shaped cavity embeds analyte rods along a boundary and iris-like central region, enabling accurate resonance wavelength shifts when the refractive index changes.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What performance indicators demonstrate the biosensor’s effectiveness?",{"text":118,"@type":114},"The biosensor achieves high transmission efficiency, strong sensitivity, and a high quality factor that produces sharp, well-defined resonance peaks.",{"name":120,"@type":111,"acceptedAnswer":121},"How does temperature affect the biosensor’s operation?",{"text":122,"@type":114},"The sensor maintains stable performance over a broad temperature range of 25 °C to 75 °C.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},366034,1790252080,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":19,"preview_urls":147},962085564549,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","[www. nature.com/scientificreports](www. nature.com/scientificreports)  \nOPEN  \nPhotonic crystal biosensor featuring an eye-shaped cavity for precise identification of cancerous cells  \nSalma Rizk1,2, Seham Abd-Elsamee1, El SaidA. Marzouk1 & Nihal F. F. Areed1􀀍  \nThis article presents a highly sensitive and thermally stable photonic crystal (PhC) biosensor designed for accurate cancer-cell detection. The proposed sensor features a square-lattice of silicon rods (radius 0.1 µm) with a photonic bandgap spanning 1.2–2.1 µm. It includes two line-defect waveguides for input and output, and a uniquely engineered Eye-shaped cavity that holds the analyte as embedded rods. These rods are strategically arranged along the Eye-shaped boundary and the central area resembling an iris, facilitating accurate detection through resonance wavelength shifts triggered by changes in the refractive index. The biosensor demonstrates excellent transmission efficiency (69.7%–99.9%), high sensitivity (236–243 nm/RIU), and a strong quality factor (15,764–87,070), ensuring sharp and clearly defined resonance peaks. A key advantage of the design is its linear response to refractive index variations, which enhances detection accuracy and supports reliable real-time biosensing. Moreover, the sensor maintains stable performance across a wide temperature range (25 °C to 75 °C) and exhibits robust tolerance to fabrication variations. These features validate the biosensor’s precision for biomedical diagnostics.  \nKeywords Photonic crystal (PhC), Biosensor, Refractive index (RI), Cancer detection, Sensitivity, Q-factor  \nCardiovascular diseases, cancers, diabetes, and respiratory diseases account for more than 60% of all deaths worldwide.1. Cancer is an illness characterized by abnormal and uncontrolled cell growth. Common types include cervical cancer (HeLa), skin cancer (Basal), two breast cancers (MDA-MB-231 and MCF-7), blood cancer (Jurkat), and adrenal gland cancer (PC12)2–5. A well-known traditional cancer analysis requires considerable time, money, and large-volume blood samples for detection.6. New biomedical research focuses on innovating Lab-On-A-Chip biosensors for quick and precise outcomes7.  \nRecent advances in optics and photonics demonstrate the rapid evolution of the field and its potential to open the door to new sensing technologies. One of the most promising areas is photonic crystal-based devices, which can control light with great precision and have shown strong potential in sensing applications. Refractive index (RI)-based sensors are valued for their high sensitivity, real-time detection, and versatility. They have been used to detect organic compounds, hazardous chemicals.8. biomolecules, pathogens9, pressure 10,, temperature 11, glucose concentration12 and flow in microfluidic systems. 10 This broad applicability highlights the importance of customizing RI sensors for specific needs, supporting the development of the photonic crystal-based biosensor introduced in this work. Biosensors are very sensitive and can detect small amounts quickly. They have a compact design, are measured in microns and nanometres, and can be integrated with optical circuits. (OICs) 13. One of these biosensors is PhC biosensors. PhCs are made up of regular patterns of materials that either contain electric charges (dielectric) or metals (Metallo-dielectric) with varying dielectric constant materials in different values.  \n14. These biosensors are available in different forms, including one-dimensional (1D), two-dimensional (2D), and fibre-based configurations. They are widely utilized in resonators. 15, waveguides 16, fibres 17, switches 18 and biosensors 19. These structures are designed to influence the electromagnetic wave propagation within them. Due to this regular pattern, light transmission is obstructed in specific ranges of frequencies, creating a Photonic Band Gap (PBG) 20. Defects occur in these repeated structures, the periodicity is entirely disrupt","cbCaiuhVKTSkVuTf","https://ap.wps.com/l/cbCaiuhVKTSkVuTf","pdf",2082769,11,"English","# Introduction\n## Need for faster cancer detection\n## Photonic-crystal devices and refractive-index biosensing\n## Structure and principles of photonic crystal biosensors","[{\"question\":\"How does the eye-shaped cavity improve cancer-cell identification?\",\"answer\":\"The Eye-shaped cavity embeds analyte rods along a boundary and iris-like central region, enabling accurate resonance wavelength shifts when the refractive index changes.\"},{\"question\":\"What performance indicators demonstrate the biosensor’s effectiveness?\",\"answer\":\"The biosensor achieves high transmission efficiency, strong sensitivity, and a high quality factor that produces sharp, well-defined resonance peaks.\"},{\"question\":\"How does temperature affect the biosensor’s operation?\",\"answer\":\"The sensor maintains stable performance over a broad temperature range of 25 °C to 75 °C.\"}]","Photonic crystal biosensor featuring an eye-shaped cavity for precise identification of cancerous cells | PDF",1790163642,28,[148,152,156,160],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/2faec8dd437c4fcdafa8e4dbea7c54da.webp",983,1291,{"page_no":14,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/ca3361755dbbdc3dd6ccd9a16c9ef261.webp",982,1290,{"page_no":81,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/8912673733329009f13320457ccc7ee5.webp",981,1289,{"page_no":19,"url":161,"width":162,"height":163},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/57239e1f7f8aeb302e38d34787bd01e0.webp",980,1287]