[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663446-105":59,"doc-detail-663446-en":134},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":127,"head_meta":129,"extra_data":131,"updated_unix":133},105,"en","ph202s-ph-orp-transmitter-installation-and-wiring-guide","PH202S pH-ORP Transmitter - Installation and Wiring Guide","","This technical document provides detailed specifications and installation guidelines for the PH202S pH-ORP transmitter. It covers physical dimensions, weight, and mounting configurations, including both pipe and panel mounting options. The guide features comprehensive wiring diagrams, illustrating the connection of the two-wire system with safety barriers for explosion-proof applications. It also specifies requirements for cable glands and conduit hardware to ensure proper device integration and compliance with industrial standards.",{"@graph":69,"@context":126},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/ph202s-ph-orp-transmitter-installation-and-wiring-guide/663446/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/ph202s-ph-orp-transmitter-installation-and-wiring-guide/663446.png","ImageObject",300,407,{"name":92,"@type":93},"dbqoiu","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118,122],{"name":109,"@type":110,"acceptedAnswer":111},"What are the mounting options available for the PH202S transmitter?","Question",{"text":112,"@type":113},"The PH202S supports both pipe mounting (vertical or horizontal) and panel mounting using dedicated hardware kits.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What is the weight of the PH202S transmitter unit alone?",{"text":117,"@type":113},"The weight of the PH202S transmitter is approximately 1.6 kg.",{"name":119,"@type":110,"acceptedAnswer":120},"Is a safety barrier required for all installations?",{"text":121,"@type":113},"A safety barrier is required for intrinsically safe approval; however, it is not necessary for non-incendive types (PH202S-B, -N, -D).",{"name":123,"@type":110,"acceptedAnswer":124},"What type of cable should be used for the transmission signal?",{"text":125,"@type":113},"Use a two-wire cable with an outside diameter (OD) of 6 to 12 mm.","https://schema.org",{"og:url":83,"og:type":128,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":130,"canonical":83},"index,follow",{"doc_id":132,"site_id":62},663446,1793227791,{"code":4,"msg":5,"data":135},{"doc_id":132,"user_id":136,"nickname":92,"user_avatar":137,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":138,"file_id":139,"file_url":140,"file_type":141,"file_size":142,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":143,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":144,"faqs":145,"seo_title":146,"seo_description":67,"update_tm":133,"read_time":24},3985747862462,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","|  |  |\n| --- | --- |\n|  |  |\n| Drawings 2-wire pH/ORP Metering system\u003Cbr>PH202S [Style: S2, S3] pH/ORP Transmitter | |\n|  |  |\n\nUnit : mm  \n96  68  \nG(roM4usreingw)trminal~~3~~560.2 Scealseorglcabandle(Pingle1t3.5)  \nTransmission signal cable inlet Cable gland : Pg13 .5  \nM6 screw (32)  \nWeight: : Approx. 1.6 kg  \nWiring Diagrams  \nExample of Explosionproof System  \nu Adapter Coduit Work (optional)(Option code : / AFTG, / ANSI)  \nApprox. 55  \nAdapter  \nu G1/2 screw (AFTG)  \nu 1/2 NPT screw (/ANSI)  \n*2  \nDistributor  \nSafety Barrier  \n*3  \nPH202S  \npH/ORP pH/ORP Transmitter Sensor  \n*1  \n+  \n-  \nG  \nOutput  \nGround to earth  \n*1: This cable is specified by the additional code of a pH sensor, or a sensor cable.  \n*2: Use two-wire cable with OD (Outside Diameter) of 6 to 12 mm.  \n*3: For intrinsically safe approval, use the safety barrier certified by the testing laboratories. In case of non-incendive type (PH202S-B, -N, -D), the safety barrier is not neccessary.  \nWiringDia1s.EPS  \nUnless otherwise specified, differences in the dimensions are specified as : General tolerance = 6(Criteria of trelance class IT18 in JIS B0401-1986)/2  \nAll Rights Reserved, Copyright © 2007, Yokogawa Electric Corporation.  \nSubject to change without notice.  \nSD 12B07D02-21E 1/2 1st Edition: May. 2007 (YK)  \n2nd Edition: Feb. 2008 (YK)  \nUnit : mm  \nu Pipel Mounting Hardware (Option code : / U ) Weight : Approx. 0.4kg  \n200  \nPipe mounting (Vertical)  \nPipe mounting (Horizontal)  \nNominal 50 A (O. D. [60.5 mm)  \nu Panel Mounting Hardware (Option code : /PM) Weight : Approx. 0.4kg  \nPanel  thickness  \n1 to 10 Panel mounting  \nbracket  \nPanel Mounting when using two(2) self-tapping screws  \nUnit: mm (inch)  0+1  \n18.5  \n(0.72)  \n3.5 (0.14)  \nPANEL CUTOUT  \nUnless otherwise specified, differences in the dimensions are specified as : General tolerance = 6(Criteria of trelance class IT18 in JIS B0401-1986)/2  \nSD 12B07D02-21E 2/2 1st Edition: May. 2007 (YK)  \n2nd Edition: Feb. 2008 (YK)","cbCaio5gwxg9YmAw","https://ap.wps.com/l/cbCaio5gwxg9YmAw","pdf",105023,"English","# Wiring Diagrams\n## Explosion-proof System Configuration\n# Mounting Hardware\n## Pipe Mounting\n## Panel Mounting","[{\"question\":\"What are the mounting options available for the PH202S transmitter?\",\"answer\":\"The PH202S supports both pipe mounting (vertical or horizontal) and panel mounting using dedicated hardware kits.\"},{\"question\":\"What is the weight of the PH202S transmitter unit alone?\",\"answer\":\"The weight of the PH202S transmitter is approximately 1.6 kg.\"},{\"question\":\"Is a safety barrier required for all installations?\",\"answer\":\"A safety barrier is required for intrinsically safe approval; however, it is not necessary for non-incendive types (PH202S-B, -N, -D).\"},{\"question\":\"What type of cable should be used for the transmission signal?\",\"answer\":\"Use a two-wire cable with an outside diameter (OD) of 6 to 12 mm.\"}]","PH202S pH-ORP Transmitter - Installation and Wiring Guide | PDF"]