[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-676065-105":3,"doc-detail-676065-en":83,"detail-sidebar-cat-0-en-105":99},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":76,"head_meta":78,"extra_data":80,"updated_unix":82},105,"en","performus-ii-viii-dispensing-system-operating-manual","Performus II - VIII Dispensing System Operating Manual","","User’s guide for Nordson EFD Performus II–VIII industrial dispensing systems, designed to help operators maximize system usefulness through familiarization with controls, features, and recommended testing procedures. Provides guidance for setup, syringe barrel filling, barrel loaders, replacement parts, accessories, troubleshooting, and helpful setting suggestions. Includes product safety information emphasizing disposable component single-use, required protective equipment, limits on operating and air pressure, temperature restrictions, and solvent cleaning prohibitions, plus electric shock and read-manual warnings.",{"@graph":14,"@context":75},[15,34,54],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/performus-ii-viii-dispensing-system-operating-manual/676065/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":48,"encodingFormat":47,"isAccessibleForFree":49,"interactionStatistic":50},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/performus-ii-viii-dispensing-system-operating-manual/676065.png","ImageObject",300,407,{"name":42,"@type":43},"673605","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-04",true,{"@type":51,"interactionType":52,"userInteractionCount":4},"InteractionCounter",{"@type":53},"ViewAction",{"@type":55,"mainEntity":56},"FAQPage",[57,63,67,71],{"name":58,"@type":59,"acceptedAnswer":60},"What is the purpose of this Performus II–VIII dispensing system user’s guide?","Question",{"text":61,"@type":62},"It helps operators maximize the usefulness of the Performus dispensing system by familiarizing users with controls and features and guiding recommended testing and operation procedures.","Answer",{"name":64,"@type":59,"acceptedAnswer":65},"Why must disposable components be used only once?",{"text":66,"@type":62},"EFD disposable components are precision engineered for one-time use; cleaning and re-use can compromise dispensing accuracy and increase the risk of personal injury.",{"name":68,"@type":59,"acceptedAnswer":69},"What key safety limits are stated for operating pressure and temperature?",{"text":70,"@type":62},"Do not exceed a maximum operating pressure of 100 psi (7.0 kg/cm2), and do not heat syringe barrels or cartridges above 100°F (38°C).",{"name":72,"@type":59,"acceptedAnswer":73},"What should be done if there is an electrical shock?",{"text":74,"@type":62},"Shut down all equipment immediately and do not restart until the problem has been identified and corrected.","https://schema.org",{"og:url":32,"og:type":77,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":79,"canonical":32},"index,follow",{"doc_id":81,"site_id":7},676065,1793774759,{"code":4,"msg":84,"data":85},"success",{"doc_id":81,"user_id":86,"nickname":42,"user_avatar":11,"doc_module":4,"category_id":87,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":88,"file_id":89,"file_url":90,"file_type":91,"file_size":92,"view_count":4,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":93,"language":94,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":95,"faqs":96,"seo_title":97,"seo_description":12,"update_tm":82,"read_time":98},673605,6,"Performus™ II, III, IV, V, VI, VII, VIII  \nDispensing System Operating Manual  \nOriginal Document  \nElectronic pdf files of Nordson EFD manuals are also available [at www.nordsonefd.com](at www.nordsonefd.com)  \n[www.nordsonefd.com](www.nordsonefd.com) [info@nordsonefd.com](info@nordsonefd.com) USA & Canada 800-556-3484 Europe +44 (0) 1582 666334 India+ 91 80 4021 3600 Asia +China: +86 (21) 3866 9006  \n2  \n[www.nordsonefd.com](www.nordsonefd.com)  \n[info@nordsonefd.com](info@nordsonefd.com) USA & Canada 800-556-3484 Europe +44 (0) 1582 666334 India+ 91 80 4021 3600 Asia +China: +86 (21) 3866 9006  \nIntroduction  \nYou have selected a reliable, high quality Performus dispensing system from Nordson EFD, the world leader in fluid dispensing. The Performus dispensing system was designed specifically for industrial dispensing, and will provide you with years of trouble-free, productive service.  \nThis User’s Guide will help you maximize the usefulness of your Performus dispensing system.  \nPlease spend a few minutes to become familiar with the controls and features. Follow our recommended testing procedures. Review the helpful information we have included, which is based on more than 30 years of industrial dispensing experience.  \nMost questions you will have are answered in this guide. However, if you need assistance, please do not hesitate to contact EFD or your authorized EFD distributor.  \nIn the USA, call 800-556-3484 between 8:00 a. m. and 5:30 p. m. Eastern time.  \nIn Europe, call +44 (0) 1582 666334.  \nIn Asia, call +86 (21) 3866 9006.  \nIn all other areas, call your authorized Nordson EFD distributor or +1-401-431-7000 .  \nThe EFD Pledge  \nThank You!  \nYou have just purchased the world’s finest dispensing equipment.  \nI want you to know that all of us at Nordson EFD value your business and will do everything in our power to make you a satisfied customer.  \nIf at any time you are not fully satisfied with our equipment or the support provided by your EFD Product Application Specialist, please contact me personally at 800-556-3484 (US), 401-431-7000 (outside US), or [jeff.pembroke@nordsonefd.com](jeff.pembroke@nordsonefd.com).  \nI guarantee that we will resolve any problems to your satisfaction.  \nThanks again for choosing Nordson EFD.  \nKen Forden  \nKen Forden, General Manager  \n[www.nordsonefd.com](www.nordsonefd.com) [info@nordsonefd.com](info@nordsonefd.com) USA & Canada 800-556-3484 Europe +44 (0) 1582 666334 India+ 91 80 4021 3600 Asia +China: +86 (21) 3866 9006  \n3  \nContents  \nNordson EFD Product Safety Information ......................5-8  \nSpecifications..................................................................9  \nFeatures and Controls ..............................................10-17  \nPerformus V-VIII ....................................................10-13  \nPerformus III-IV ....................................................14-15  \nPerformus II..........................................................16-17  \nGetting Started ........................................................18-19  \nDispensing System Setup ........................................20-22  \nFilling the Syringe Barrel ..........................................23-24  \nBarrel Loaders ..............................................................25  \nReplacement Parts ..................................................26-27  \nAccessories ..................................................................28  \nTroubleshooting Guide ..................................................29  \nHelpful Hints/Suggestions on Settings ............................30  \nWarranty ......................................................................31  \nIMPORTANT SAFETY INFORMATION  \nAll EFD disposable components, including syringe barrels, cartridges, pistons, tip caps, end caps, and dispense tips, are precision engineered for one-time use. Attempting to clean and re-use components will compromise dispensing accuracy and may increase the risk of personal i","cbCaiiDI7QhRvmHQ","https://ap.wps.com/l/cbCaiiDI7QhRvmHQ","pdf",652892,32,"English","# Introduction\n## The EFD Pledge\n# Contents\n## Nordson EFD Product Safety Information\n## Specifications\n## Features and Controls\n## Performus V-VIII\n## Performus III-IV\n## Performus II\n## Getting Started\n## Dispensing System Setup\n## Filling the Syringe Barrel\n## Barrel Loaders\n## Replacement Parts\n## Accessories\n## Troubleshooting Guide\n## Helpful Hints/Suggestions on Settings\n## Warranty\n# IMPORTANT SAFETY INFORMATION\n## Nordson EFD Product Safety Statement","[{\"question\":\"What is the purpose of this Performus II–VIII dispensing system user’s guide?\",\"answer\":\"It helps operators maximize the usefulness of the Performus dispensing system by familiarizing users with controls and features and guiding recommended testing and operation procedures.\"},{\"question\":\"Why must disposable components be used only once?\",\"answer\":\"EFD disposable components are precision engineered for one-time use; cleaning and re-use can compromise dispensing accuracy and increase the risk of personal injury.\"},{\"question\":\"What key safety limits are stated for operating pressure and temperature?\",\"answer\":\"Do not exceed a maximum operating pressure of 100 psi (7.0 kg/cm2), and do not heat syringe barrels or cartridges above 100°F (38°C).\"},{\"question\":\"What should be done if there is an electrical shock?\",\"answer\":\"Shut down all equipment immediately and do not restart until the problem has been identified and corrected.\"}]","Performus II - VIII Dispensing System Operating Manual | PDF",81,{"code":4,"msg":84,"data":100},[101,105,109,113,118,121,126,131,136,139,143],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":102,"show_sort_weight":103,"slug":104},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":106,"show_sort_weight":107,"slug":108},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":110,"show_sort_weight":111,"slug":112},"Exam",70,"exam",{"id":114,"doc_module":4,"doc_module_name":25,"category_name":115,"show_sort_weight":116,"slug":117},5,"Comic",60,"comic",{"id":87,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":119,"slug":120},50,"technology",{"id":122,"doc_module":4,"doc_module_name":25,"category_name":123,"show_sort_weight":124,"slug":125},7,"Healthcare",40,"healthcare",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":129,"slug":130},8,"Research & Report",30,"research-report",{"id":132,"doc_module":4,"doc_module_name":25,"category_name":133,"show_sort_weight":134,"slug":135},9,"Religion & Spirituality",20,"religion-spirituality",{"id":134,"doc_module":4,"doc_module_name":25,"category_name":137,"show_sort_weight":134,"slug":138},"World Cup","world-cup",{"id":140,"doc_module":4,"doc_module_name":25,"category_name":141,"show_sort_weight":140,"slug":142},10,"Lifestyle","lifestyle",{"id":144,"doc_module":4,"doc_module_name":25,"category_name":145,"show_sort_weight":114,"slug":146},19,"General","general"]