[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-646319-105":59,"doc-detail-646319-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","performance-criteria-for-section-11-20-00-commercial-equipment","Performance Criteria for Section 11 20 00 - Commercial Equipment","","Performance criteria document defining requirements for commercial equipment under Section 11 20 00. Establishes compliance obligations with multiple governing standards including UFC building requirements, military construction materials scheduling, NFPA healthcare and life safety codes, and IEC medical electrical equipment requirements. Specifies performance expectations for descriptions and materials, including finishes, fabrics, infection-control performance, interoperability cybersecurity alignment, and equipment power limits. Includes detailed equipment submittals and specifications for items such as key storage cabinets, cash registers, and laundry and dry cleaning systems, covering construction, accessories, and operational features.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/performance-criteria-for-section-11-20-00-commercial-equipment/646319/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/performance-criteria-for-section-11-20-00-commercial-equipment/646319.png","ImageObject",300,407,{"name":92,"@type":93},"Stanford","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-07","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":34},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What standards must contractors comply with for Section 11 20 00 commercial equipment?","Question",{"text":112,"@type":113},"The document requires compliance with UFC general and high-performance building requirements, UFC interior design, UFC military medical facilities, MIL-STD 1691, NFPA 99 and NFPA 101, ANSI/NSF-ANSI 7, IEC 60601, and FDA CFR Title 21, among other referenced standards.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What material and finish performance requirements are specified for the equipment?",{"text":117,"@type":113},"It requires manufacturer-selected standard paints, fabrics, and finishes unless noted otherwise, including appropriate fire testing and abrasion resistance for fabrics, infection-control performance for finishes and fabrics, and maintenance of sheen and color during the warranty period under standard cleaning and disinfection solutions.",{"name":119,"@type":110,"acceptedAnswer":120},"What cybersecurity requirement applies to interoperable equipment?",{"text":121,"@type":113},"Interoperability-capable hardware must meet cybersecurity requirements aligned with DoDI 8510.01 risk management framework, applicable to DoD IT that receives, processes, stores, displays, or transmits DoD information.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},646319,1793051497,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":34,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":34,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144,"preview_page_count":4},2336477552062,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","(September 2021)  \nPERFORMANCE CRITERIA  \nFOR  \nSECTION 11 20 00  \nCOMMERCIAL EQUIPMENT  \n09/21  \nTABLE OF CONTENTS  \nGENERAL  \n1.1 REFERENCE  \n2.1 DESCRIPTION & MATERIALS  \n3.1 SUBMITTALS  \n3.2 QUALITY ASSURANCE  \n3.3 STANDARDS DEVIATIONS  \n3.4 DELIVERY, STORAGE AND PROTECTION  \n3.5 INSTALLATION, VERIFCATION AND ACCEPTANCE TESTING  \n3.6 WARRANTY  \n3.7 OPERATIONS AND MAINTENANCE (O & M)  \nGENERAL  \nThis Performance Criteria specifies the requirements for commercial equipment.  \n1.1 REFERENCE  \n1.1.1 Unified Facilities Criteria (UFC)  \nContractor must comply with the following:  \nA. UFC 1-200-01 General Building Requirements  \nB. UFC 1-200-02 High Performance and Sustainable Building Requirements  \nC. UFC 3-120-10 Interior Design  \nD. UFC 4-510-01 Military Medical Facilities  \n1.1.2 Military Standard  \nA. MIL-STD 1691 Construction and Material Schedule for Medical, Dental, Veterinary and Medical Research Laboratories  \n1.1.3 National Fire Protection Association (NFPA)  \nA. NFPA 99 Healthcare Facilities Code  \nB. NFPA 101 Life Safety Code  \n1.1.4 Military Health Services Standards  \nA. Reserved for future  \n1.1.5 American National Standards Institute (ANSI)  \nA. NSF/ANSI 7 Commercial Refrigerators and Freezers  \n1.1.6 International Electrotechnical Commission (IEC)  \nA. IEC 60601 Medical Electrical Equipment and Systems  \n1.1.7 Food and Drug Administration  \nA. CFR Title 21, Chapter I  \n1.1.8 Other Standards  \nA. Reserved for future  \n2.1 DESCRIPTION & MATERIALS  \nAll requirements within the MIL-STD 1691 JSN descriptions must be met as well as the performance guidelines listed in the following descriptions.  \n2.1.1 All JSN’S  \nA. Paints, fabrics, and finishes will be selected from the manufacturer’s standard options for the specified model unless noted otherwise.  \nB. All fabrics (upholstery or drapery) must meet the appropriate fire test associated with each type of fabric as outlined by testing within the reference standards.  \nC. All fabrics (upholstery) must meet the appropriate resistance to abrasion test associated with each type of fabric as outlined by testing within the reference standards.  \nD. All product finishes and fabrics (upholstery or drapery) must meet industry standards for infection control and performance.  \nE. All product finishes must be capable of maintaining sheen and color through warranty period when using industry standard cleaning and disinfection solutions.  \nF. All display panel surfaces must maintain clarity through warranty period when using industry standard cleaning and disinfection solutions.  \nG. All equipment that have components that are meant for reuse must be autoclavable or able to withstand industry standard cleaning and disinfection processes.  \nH. Electrified equipment must be 115 Volt 15 amp maximum unless noted otherwise.  \nI. Casters provided must be designed for use on the installed floor finish.  \nJ. All products that have interoperability capable hardware (i.e. internal storage, data transmission via wireless, Ethernet, LAN, or USB to PC or server connectivity) must meet Cybersecurity requirements in accordance with DoDI  \n8510.01 Risk Management Framework.  \nK. DoDI 8510.01 applies to all DoD IT (medical devices included) that receive, process, store, display, or transmit DoD information. These technologies are broadly grouped as DoD IS, platform IT (PIT), IT services, and IT products. This includes IT supporting research, development, test and evaluation (T&E), and DoD-controlled IT operated by a contractor or other entity on behalf of the DoD.  \n2.1.2 Key Storage Cabinet F0490 – Cabinet, Keys  \nA. Provide factory baked enamel or powder coat finish.  \nB. Provide [20] [40] [60] [80] [100][150] key capacity.  \nC. Provide predrilled holes and mounting hardware for wall mounting.  \nD. Provide ability to lock cabinet with [key] [combination] [electronic lock] .  \nE. Provide cabinet that is constructed of all-welded steel with heavy duty hinges.  \n2.1.3 Cash Register  \nF2125 – Cash ","cbCaivpkAM4nZL6i","https://ap.wps.com/l/cbCaivpkAM4nZL6i","pdf",117764,"English","# GENERAL\n## 1.1 REFERENCE\n## 2.1 DESCRIPTION & MATERIALS\n### 2.1.1 All JSN’S\n### 2.1.2 Key Storage Cabinet F0490 – Cabinet, Keys\n### 2.1.3 Cash Register F2125 – Cash Register, With Locking Drawer\n### 2.1.4 Laundry and Dry Cleaning Equipment","[{\"question\":\"What standards must contractors comply with for Section 11 20 00 commercial equipment?\",\"answer\":\"The document requires compliance with UFC general and high-performance building requirements, UFC interior design, UFC military medical facilities, MIL-STD 1691, NFPA 99 and NFPA 101, ANSI/NSF-ANSI 7, IEC 60601, and FDA CFR Title 21, among other referenced standards.\"},{\"question\":\"What material and finish performance requirements are specified for the equipment?\",\"answer\":\"It requires manufacturer-selected standard paints, fabrics, and finishes unless noted otherwise, including appropriate fire testing and abrasion resistance for fabrics, infection-control performance for finishes and fabrics, and maintenance of sheen and color during the warranty period under standard cleaning and disinfection solutions.\"},{\"question\":\"What cybersecurity requirement applies to interoperable equipment?\",\"answer\":\"Interoperability-capable hardware must meet cybersecurity requirements aligned with DoDI 8510.01 risk management framework, applicable to DoD IT that receives, processes, stores, displays, or transmits DoD information.\"}]","Performance Criteria for Section 11 20 00 - Commercial Equipment | PDF",1792756971,18]