[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-465584-105":59,"doc-detail-465584-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","performance-comparison-of-u-net-and-its-variants-for-carotid-intimamedia-segmentation-in-ultrasound-images","Performance Comparison of U-Net and Its Variants for Carotid Intima–Media Segmentation in Ultrasound Images","","This study systematically compares U-Net and multiple variants for automated carotid intima-media thickness (CIMT) segmentation in ultrasound images, targeting both segmentation accuracy and real-time efficiency. Ten models are trained and evaluated on the publicly available CUBS dataset (2176 images, 1088 subjects) using uniform preprocessing and shared hyperparameters. Accuracy is quantified with Dice, IoU, precision, recall, and accuracy metrics, while efficiency is assessed via training/inference time and parameter counts. Attention U-Net achieves the highest segmentation accuracy; UNeXt provides the fastest runtime. UNet++ yields smoother, more natural boundaries, and the parameter–Dice tradeoff is visualized for model selection.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/performance-comparison-of-u-net-and-its-variants-for-carotid-intimamedia-segmentation-in-ultrasound-images/465584/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/performance-comparison-of-u-net-and-its-variants-for-carotid-intimamedia-segmentation-in-ultrasound-images/465584.png","ImageObject",300,407,{"name":92,"@type":93},"Sophia Brooks","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-08","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":44},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What problem does the study address in carotid ultrasound analysis?","Question",{"text":112,"@type":113},"It addresses automated segmentation of carotid intima-media thickness (CIMT) using U-Net and its variants, focusing on achieving accurate boundaries while maintaining real-time efficiency.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which dataset and preprocessing strategy are used for training and evaluation?",{"text":117,"@type":113},"Ten models are trained and evaluated on the CUBS dataset, with images preprocessed using histogram-based smoothing and resized to 256×256 pixels.",{"name":119,"@type":110,"acceptedAnswer":120},"How do different model variants compare in accuracy and speed?",{"text":121,"@type":113},"Attention U-Net delivers the highest segmentation accuracy, while UNeXt shows the fastest training/inference speeds. UNet++ is noted for producing smooth and natural boundary reconstructions.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},465584,1790811597,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":44,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":36,"preview_page_count":19,"preview_urls":145},962084925636,"https://ap-avatar.wpscdn.com/davatar_994ba38a5ba835b3df7d355c54d3ed8d","Article  \nPerformance Comparison of U-Net and Its Variants for Carotid Intima–Media Segmentation in Ultrasound Images  \nSeungju Jeong 1,†, Minjeong Park 1,†, Sumin Jeong 2, * and Dong Chan Park 1, *  \nAcademic Editor: Zhuhuang Zhou  \nReceived: 9 October 2025  \nRevised: 8 December 2025  \nAccepted: 16 December 2025  \nPublished: 19 December 2025  \nCopyright: © 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \n1 Division of Artificial Intelligence Engineering, Korea Maritime and Ocean University, Busan 49112, Republic of Korea; [wjdtmd2323@g.kmou.ac.kr](wjdtmd2323@g.kmou.ac.kr) (S.J.); [popop0078@g.kmou.ac.kr](popop0078@g.kmou.ac.kr) (M.P.)  \n2 Department of Electronic and Electrical Engineering, Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi-si 39177, Gyeongsangbuk-do, Republic of Korea  \n* Correspondence: [sumin.jeong@kumoh.ac.kr](sumin.jeong@kumoh.ac.kr) (S.J.); [dongchan@kmou.ac.kr](dongchan@kmou.ac.kr) (D.C.P.)† These authors contributed equally to this work.  \nAbstract  \nBackground/Objectives: This study systematically compared the performance of U-Net and variants for automatic analysis of carotid intima-media thickness (CIMT) in ultrasound images, focusing on segmentation accuracy and real-time efficiency. Methods: Ten models were trained and evaluated using a publicly available Carotid Ultrasound Boundary Study (CUBS) dataset (2176 images from 1088 subjects) . Images were preprocessed using histogram-based smoothing and resized to a resolution of 256 × 256 pixels. Model training was conducted using identical hyperparameters (50 epochs, batch size 8, Adam optimizer with a learning rate of 1 × 10−4, and binary cross-entropy loss) . Segmentation accuracy was assessed using Dice, Intersection over Union (IoU), Precision, Recall, and Accuracy metrics, while real-time performance was evaluated based on training/inference times and the model parameter counts. Results: All models achieved high accuracy, with Dice/IoU scores above 0.80/0.67 . Attention U-Net achieved the highest segmentation accuracy, while UNeXt demonstrated the fastest training/inference speeds (approximately 420,000 parameters) . Qualitatively, UNet++ produced smooth and natural boundaries, highlighting its strength in boundary reconstruction. Additionally, the relationship between the model parameter count and Dice performance was visualized to illustrate the tradeoff between accuracy and efficiency. Conclusions: This study provides a quantitative/qualitative evaluation of the accuracy, efficiency, and boundary reconstruction characteristics of U-Netbased models for CIMT segmentation, offering guidance for model selection according to clinical requirements (accuracy vs. real-time performance) .  \nKeywords: cardiovascular diseases; atherosclerosis; carotid intima-media thickness; ultrasound image segmentation; deep learning; U-Net; real-time efficiency  \n1. Introduction  \nThe CIMT is an important indicator of atherosclerosis progression and the risk of future cardiovascular events, including stroke and myocardial infarction. Elevated CIMT is directly associated with increased vascular stiffness and plaque burden, making its accurate measurement essential for patient risk stratification and monitoring therapeutic effectiveness [1] . CIMT can be assessed using various non-invasive medical imaging modalities. While magnetic resonance imaging provides excellent soft tissue contrast, its high cost and limited accessibility restrict its routine clinical use. Computed tomography offers detailed visualization but involves exposure to ionizing radiation. For routine clinical practice,  \nB-mode ultrasound remains the gold standard. It offers a cost-effective, real-time, and safe method to visualize the carotid artery wall structure. To ensure standardized assessment and reliability, internat","cbCaiqyuLaezRe4x","https://ap.wps.com/l/cbCaiqyuLaezRe4x","pdf",1596965,16,"English","# Abstract\n# 1. Introduction\n## Clinical relevance of CIMT and imaging modalities\n## Challenges of manual measurement and motivation for AI\n## Prior work on U-Net and variants for carotid/CIMT segmentation\n## Gap and study objective","[{\"question\":\"What problem does the study address in carotid ultrasound analysis?\",\"answer\":\"It addresses automated segmentation of carotid intima-media thickness (CIMT) using U-Net and its variants, focusing on achieving accurate boundaries while maintaining real-time efficiency.\"},{\"question\":\"Which dataset and preprocessing strategy are used for training and evaluation?\",\"answer\":\"Ten models are trained and evaluated on the CUBS dataset, with images preprocessed using histogram-based smoothing and resized to 256×256 pixels.\"},{\"question\":\"How do different model variants compare in accuracy and speed?\",\"answer\":\"Attention U-Net delivers the highest segmentation accuracy, while UNeXt shows the fastest training/inference speeds. UNet++ is noted for producing smooth and natural boundary reconstructions.\"}]","Performance Comparison of U-Net and Its Variants for Carotid Intima–Media Segmentation in Ultrasound Images | PDF",1790769791,[146,150,154,158],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/87766f3412c396c2f9d9819ceb681bd5.webp",983,1390,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/a4c2371725304e90acd67078056865f7.webp",982,1388,{"page_no":81,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/aff582b2aa4d8e177401d0131dd374ca.webp",981,1387,{"page_no":19,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/9ba33f62ba1642bb410f4c1bd1d6b10c.webp",980,1385]