[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-228464-105":59,"doc-detail-228464-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","patient-specific-instrumentation-shaping-the-future-of-knee-arthroplasty-dissertation","Patient-Specific Instrumentation - Shaping the Future of Knee Arthroplasty - Proefschrift","","Patient-Specific Instrumentation explores how individualized planning and measurement can improve total knee arthroplasty. The thesis covers weight-bearing versus non-weight-bearing leg alignment, assesses lower-limb alignment measurement modalities, and evaluates patient-specific approaches for planning and predicting implant component size. It examines reliability of MRI-based planning, consistency in patient-reported outcomes over follow-up, and digital pre- and intraoperative planning tools including comparisons with X-PSI™. The dissertation concludes with impact, summary, and general discussion.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/patient-specific-instrumentation-shaping-the-future-of-knee-arthroplasty-dissertation/228464/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/patient-specific-instrumentation-shaping-the-future-of-knee-arthroplasty-dissertation/228464.png","ImageObject",300,407,{"name":92,"@type":93},"Lute","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-06","2026-09-10",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",14,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What is the central focus of the thesis?","Question",{"text":113,"@type":114},"The thesis focuses on patient-specific instrumentation and how individualized measurement and planning can shape the future of total knee arthroplasty.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How does the dissertation address leg alignment measurement?",{"text":118,"@type":114},"It examines differences between weight-bearing and non-weight-bearing leg alignment and evaluates lower-limb alignment measurement modalities, including within-person comparisons.",{"name":120,"@type":111,"acceptedAnswer":121},"Which planning and digital tools are compared in the later chapters?",{"text":122,"@type":114},"The dissertation compares preoperative planning using X-PSI™ with MRI-based patient-specific instrumentation and reviews computer-based pre- and intraoperative planning modalities for total knee arthroplasty.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},228464,1789025565,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":130,"read_time":145,"preview_page_count":4},137454149569,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","Patient-Specific Instrumentation  \nShaping the Future of Knee Arthroplasty?  \nDaphne Schoenmakers  \nPatient-Specific Instrumentation  \nShaping the Future of Knee Arthroplasty?  \nDaphne Schoenmakers  \nAuthor: Daphne Schoenmakers  \nArt, cover design & layout: Daphne Schoenmakers ISBN: 978-94-6361-969-1  \nPrinted by: Optima Grafische Communicatie  \nFinancial support for this thesis was provided by:  \nAnnafonds, ChiroMotion, Hanssen Footcare, Livit Ottobock Care, Nederlandse  \nOrthopaedische Vereniging (NOV), Penders Voetzorg, Spronken Orthopedie, Q-concepts  \nCopyright 􀂤 D.A. L. Schoenmakers, Maastricht 2024  \nAll rights reserved. No part of this book may be reproduced or transmitted in any form or by any means, without prior permission in writing by the author or, when appropriate, by the publishers of the publications.  \nPatient-Specific Instrumentation  \nShaping the Future of Knee Arthroplasty?  \nPROEFSCHRIFT  \nTer verkrijging van de graad van doctor aan de Universiteit Maastricht,  \nonder gezag van Rector Magnificus, Prof. dr. Pamela Habibović, overeenkomstig met het besluit van het college van Decanen, te verdedigen in het openbaar op woensdag 19 juni 2024 om 13:00 uur  \ndoor  \nDaphne Anne Laura Schoenmakers  \nPromotor  \nProf. dr. L.W. van Rhijn  \nCopromotores  \nDr. N. P. Kort  \nDr. M.G. M. Schotanus  \nBeoordelingscommissie  \nEm. Prof. dr. I.C. Heyligers Prof. dr. J.J.C. Arts  \nProf. dr. L. H. Bouwman Em. Prof. dr. S. K. Bulstra Dr. R.C. I. van Geenen  \nUniversiteit Maastricht / Universiteit Utrecht  \nCortoClinics  \nZuyderland Medisch Centrum  \nUniversiteit Maastricht (voorzitter)  \nUniversiteit Maastricht / Technische Universiteit Eindhoven Universiteit Maastricht / Zuyderland Medisch Centrum Universitair Medisch Centrum Groningen  \nAmphia  \nCONTENT  \nChapter 1 General introduction and thesis outline 9  \nPart I-Weight-bearing and non-weight-bearing leg alignment  \nChapter 2 Measurement of Lower Limb Alignment: There are 27  \nwithin-person differences between Weight-Bearing and  \nNon-Weight-Bearing Measurement Modalities  \nKnee Surg Sports TraumatolArthrosc, 2017, 25, 3569-3575.  \nPart II-Planning in Patient-Specific Instrumentation  \nChapter 3 High intra-and interobserver reliability of planning implant 47  \nsize in MRI-based patient-specific instrumentation for total  \nknee arthroplasty  \nKnee Surg Sports TraumatolArthrosc, 2021, 29, 573-578.  \nChapter 4 Patient-specific instruments for total knee arthroplasty can 63  \naccurately predict the component size as used peroperative  \nKnee Surg Sports TraumatolArthrosc, 2017, 25, 3844-3848.  \nChapter 5 Consistency in patient-reported outcome measures after 77  \ntotal knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases  \nKnee Surg Sports TraumatolArthrosc, 2018, 26, 1800–1804.  \nPart III-Innovations in digital pre-and intraoperative planning modalities for TKA Chapter 6 Preoperative planning with X-PSI™ compared to MRI-based 93  \npatient-specific instrumentation in total knee arthroplasty  \nIn review at J Clin Orthop Trauma, submitted August 2022.  \nChapter 7 Computer-based pre-and intraoperative planning modalities 111  \nfor Total Knee Arthroplasty: A comprehensive review  \nJ Orthop Exp Innov, accepted November 2023.  \nChapter 8 General discussion 139  \nChapter 9 Impact paragraph 161  \nChapter 10 Summary 171  \nSamenvatting 175  \nRésumé 179  \nAppendices Abbreviations 187  \nPublications 191  \nDankwoord 195  \nCurriculum vitae 201  \n~~ ~~ 1 ~~ ~~  \nGeneral introduction Thesis outline","cbCaiqxdop3exE1P","https://ap.wps.com/l/cbCaiqxdop3exE1P","pdf",4115780,204,"English","# CONTENT\n## Chapter 1 General introduction and thesis outline\n## Part I-Weight-bearing and non-weight-bearing leg alignment\n## Chapter 2 Measurement of Lower Limb Alignment: There are 27 within-person differences between Weight-Bearing and Non-Weight-Bearing Measurement Modalities\n## Part II-Planning in Patient-Specific Instrumentation\n## Chapter 3 High intra-and interobserver reliability of planning implant size in MRI-based patient-specific instrumentation for total knee arthroplasty\n## Chapter 4 Patient-specific instruments for total knee arthroplasty can accurately predict the component size as used peroperative\n## Chapter 5 Consistency in patient-reported outcome measures after total knee arthroplasty using patient-specific instrumentation: a 5-year follow-up of 200 consecutive cases\n## Part III-Innovations in digital pre-and intraoperative planning modalities for TKA\n## Chapter 6 Preoperative planning with X-PSI™ compared to MRI-based patient-specific instrumentation in total knee arthroplasty\n## Chapter 7 Computer-based pre-and intraoperative planning modalities for Total Knee Arthroplasty: A comprehensive review\n## Chapter 8 General discussion\n## Chapter 9 Impact paragraph\n## Chapter 10 Summary","[{\"question\":\"What is the central focus of the thesis?\",\"answer\":\"The thesis focuses on patient-specific instrumentation and how individualized measurement and planning can shape the future of total knee arthroplasty.\"},{\"question\":\"How does the dissertation address leg alignment measurement?\",\"answer\":\"It examines differences between weight-bearing and non-weight-bearing leg alignment and evaluates lower-limb alignment measurement modalities, including within-person comparisons.\"},{\"question\":\"Which planning and digital tools are compared in the later chapters?\",\"answer\":\"The dissertation compares preoperative planning using X-PSI™ with MRI-based patient-specific instrumentation and reviews computer-based pre- and intraoperative planning modalities for total knee arthroplasty.\"}]","Patient-Specific Instrumentation - Shaping the Future of Knee Arthroplasty - Proefschrift | PDF",514]