[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-468347-105":59,"doc-detail-468347-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","passively-ultra-cooling-patch-enabling-high-efficiency-power-water-cogeneration","Passively Ultra Cooling Patch Enabling High-Efficiency Power-Water Cogeneration","","Photovoltaic (PV) systems face performance and lifespan limits from substantial waste heat generated via the photothermal effect. This research presents a passive cooling strategy using an ultra-cooling patch (UCP) that cools PV panels with nearly 700 W m−2 cooling power, recovering over 70% of waste heat for freshwater production. The flexible, adhesive UCP integrates easily with diverse PV configurations, including flexible panels, and can be reconfigured into finer structures to modify heat pathways. A 29 °C temperature reduction and over 28% power-density increase are demonstrated, with outdoor validation on an ~1 m2 PV panel, offering scalable, cost-effective commercial potential to ease energy-water constraints.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/passively-ultra-cooling-patch-enabling-high-efficiency-power-water-cogeneration/468347/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/passively-ultra-cooling-patch-enabling-high-efficiency-power-water-cogeneration/468347.png","ImageObject",300,407,{"name":92,"@type":93},"Valentina","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-12","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",15,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What problem does the study address in photovoltaic (PV) systems?","Question",{"text":113,"@type":114},"PV systems generate substantial waste heat from the photothermal effect, which reduces electricity generation efficiency and accelerates PV panel degradation.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How does the ultra-cooling patch (UCP) improve PV performance?",{"text":118,"@type":114},"The UCP passively cools the PV panel, achieving nearly 700 W m−2 cooling power and recovering over 70% of waste heat for freshwater production.",{"name":120,"@type":111,"acceptedAnswer":121},"What evidence supports the cooling performance and practical applicability?",{"text":122,"@type":114},"Outdoor experiments on an approximately 1 m² PV panel validate the cooling performance and its practical integration potential across configurations.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},468347,1791162486,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":52,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":19,"preview_urls":146},13056703020460,"https://ap-avatar.wpscdn.com/avatar/be000253dac470eee5d?_k=1778207105932848923","RESEARCH ARTICLE   \n[www.advmat.de](www.advmat.de)  \nPassively Ultra Cooling Patch Enabling High-Eﬃciency Power-Water Cogeneration  \nZhengyi Mao, Yao Yao, Yunhu He, Zhen Yu, Yicheng Han, Junda Shen, Xinxue Tang, Fucong Lyu, Mulin Miao, Yaxin Xu, Zhe Song, Xiaoguang Duan, Yuehong Su, Hongxing Yang,* Qiliang Wang,* and Jian Lu*  \nPhotovoltaic (PV) systems, which accounted for 75% of global renewable energy capacity in 2023, are limited by the substantial waste heat generated through the photothermal eﬀect, reducing both electricity generation eﬃciency and panel longevity. In this work, a passive cooling strategy using an ultra-cooling patch (UCP) that eﬀectively cools down the PV panel is presented, thus achieving an exceptionally high cooling power of nearly  \n700 W m−2 and facilitating the recovery of over 70% of waste heat for freshwater production. The ﬂexibility and adhesive properties of UCP allow for easy integration with various PV conﬁgurations, including ﬂexible panels. In addition, the UCP can be easily reconﬁgured into a ﬁned structure, enabling modiﬁcations to the heat transfer pathway. This passively intensiﬁes the heat dissipation of the PV panel, further enhancing the cooling performance. As a result, a remarkable temperature reduction of 29 °C for the PV panel is achieved, which in turn results in an impressive increase in maximum power density of over 28%. Moreover, outdoor experiments on a ≈1 m2 PV panel validated the cooling performance and practical applicability. This study oﬀersa solution with commercial potential to relieve the energy-water crisis, owing to its high eﬃciency, scalability, and cost-eﬀectiveness.  \n1. Introduction  \nFresh water and electricity are two of the most essential factors for the further development of modern society.[1,2] The growing population, changing climate, and increasing pollution have exacerbated global water and electricity scarcity. The utilization of solar energy for electricity and water generation is widely considered a sustainable solution to water scarcity and electricity shortages. Among all of the solar utilization technologies, photovoltaic (PV) technology is the most viable and widely adopted method for eﬀectively converting solar energy into usable electricity. In the year 2023, the global solar PV cumulative capacity reached a staggering 1500 GW, and which is estimated to contribute ≈22 .2% of the total global electricity production. [3,4] However, PV cells typically utilize only aspeciﬁc portion of the solar spectrum for electricity generation (e.g., 300–1100 nm  \nZ. Mao, Y. He, Z. Yu, Y. Han, J. Shen, F. Lyu, M. Miao, J. Lu Department of Mechanical Engineering  \nCity University of Hong Kong  \n83 Tat Chee Avenue, Kowloon, Hong Kong, China E-mail: [jianlu@cityu.edu.hk](jianlu@cityu.edu.hk)  \nY. Yao, Z. Song, H. Yang  \nRenewable Energy Research Group (RERG)  \nDepartment of Building Environment and Energy Engineering The Hong Kong Polytechnic University  \nHong Kong, China  \nE-mail: [hong-xing.yang@polyu.edu.hk](hong-xing.yang@polyu.edu.hk)  \nX. Tang  \nDepartment of Materials Science and Engineering City University of Hong Kong  \n83 Tat Chee Avenue, Kowloon, Hong Kong, China  \nThe ORCID identiﬁcation number(s) for the author(s) of this article can be found under [https://doi.org/10.1002/adma.202505002](https://doi.org/10.1002/adma.202505002)[ ](https://doi.org/10.1002/adma.202505002)© 2025 The Author(s). Advanced Materials published by Wiley-VCH GmbH. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.  \nDOI: 10.1002/adma.202505002  \nY. Xu, J. Lu  \nCity University of Hong Kong Matter Science Research Institute (Futian) Shenzhen 518045, China  \nX. Duan  \nSchool of Chemical Engineering and Advanced Materials University of Adelaide  \nAdelaide 5005, Australia  \nY. Su, Q. Wang  \nDepartment of Architecture and Built Envir","cbCaioL0z3IkBR9q","https://ap.wps.com/l/cbCaioL0z3IkBR9q","pdf",4593444,"English","# Introduction\n## Passive thermal management for photovoltaic cooling\n## Limits of photovoltaic waste heat and panel degradation","[{\"question\":\"What problem does the study address in photovoltaic (PV) systems?\",\"answer\":\"PV systems generate substantial waste heat from the photothermal effect, which reduces electricity generation efficiency and accelerates PV panel degradation.\"},{\"question\":\"How does the ultra-cooling patch (UCP) improve PV performance?\",\"answer\":\"The UCP passively cools the PV panel, achieving nearly 700 W m−2 cooling power and recovering over 70% of waste heat for freshwater production.\"},{\"question\":\"What evidence supports the cooling performance and practical applicability?\",\"answer\":\"Outdoor experiments on an approximately 1 m² PV panel validate the cooling performance and its practical integration potential across configurations.\"}]","Passively Ultra Cooling Patch Enabling High-Efficiency Power-Water Cogeneration | PDF",1790774076,25,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/02f38d311ecc08cd63148de81be8170a.webp",983,1291,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/c88fc7a585b75ca9ba1289964d266a4d.webp",982,1290,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/d940c353b4044bc9e7b46582aa5b4538.webp",981,1289,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/b74a5ebd6d53edeaf8f28a5b297eb948.webp",980,1287]