[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-350546-105":59,"doc-detail-350546-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","pancreatic-tumor-detection-in-computed-tomography-images-through-a-rotary-positional-siamese-vision-transformer","Pancreatic tumor detection in computed tomography images through a rotary positional siamese vision transformer","","Pancreatic tumor detection in CT imaging is challenging due to complex pancreas anatomy, low image contrast, and the need to reduce false negatives for malignant lesions. This study introduces the Rotary Positional Siamese Vision Transformer (RPSViT), a patch-based transformer framework that incorporates rotary positional embedding to better capture spatial relationships. A Siamese transformer encoder extracts high-level features for tumor classification, trained and tested on TCIA and MSD datasets using 5-fold cross-validation. Results report mean accuracy 96.97%, sensitivity 96.06%, specificity 100.00%, and mean AUC 0.9989.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/pancreatic-tumor-detection-in-computed-tomography-images-through-a-rotary-positional-siamese-vision-transformer/350546/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/pancreatic-tumor-detection-in-computed-tomography-images-through-a-rotary-positional-siamese-vision-transformer/350546.png","ImageObject",300,407,{"name":92,"@type":93},"Ben ","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-23","2026-09-22",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",11,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What problem does the RPSViT paper address in pancreatic CT imaging?","Question",{"text":113,"@type":114},"It targets accurate pancreatic tumor detection while addressing limitations of prior methods, especially high computational complexity and difficulty reducing false negatives for malignant lesions.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How does RPSViT model spatial information in CT images?",{"text":118,"@type":114},"RPSViT uses a patch-based tokenization with linear patch embedding and adds rotary positional embedding to capture spatial relationships for improved tumor localization.",{"name":120,"@type":111,"acceptedAnswer":121},"Which data sources and evaluation method were used to test the model?",{"text":122,"@type":114},"The model was trained and evaluated on Pancreatic-CT scan images from TCIA and MSD datasets using 5-fold cross-validation.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},350546,1790758295,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":26,"preview_page_count":19,"preview_urls":146},2336478951081,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","[www. nature.com/scientificreports](www. nature.com/scientificreports)  \nOPEN  \nPancreatic tumor detection in computed tomography images through a rotary positional siamese vision transformer  \nM. Abinaya1􀀍, M. Kalamani2 & J. Haritha3  \nVision Transformers (ViTs) are one of the powerful tools in medical imaging, providing new possibilities for pancreatic cancer diagnosis. In recent years, several studies have reported deep learning (DL) techniques to computed tomography (CT) images for pancreatic cancer diagnosis using ViT-based architectures. Existing methods often suffer from high computational complexity and there are limitations in reducing false negatives, particularly for malignant lesion. This paper proposes an intelligent pancreatic tumor detection framework called Rotary Positional Siamese Vision Transformer (RPSViT), designed to accurately detect and classify pancreatic tumors by effectively localizing abnormalities in CT scan images. RPSViT employs a patch-based approach, dividing input images into fixed-size patches that are treated as tokens via linear patch embedding. Rotary positional embedding is then incorporated to capture better spatial relationships within the images, thereby enhancing tumor localisation accuracy. The Siamese Transformer Encoder extracts high-level feature vectors from the input samples and performs disease classification. The model was trained and evaluated on Pancreatic-CT scan images from The Cancer Imaging Archive (TCIA) datasets and Medical Segmentation Decathlon (MSD) datasets using a 5-fold cross-validation. Experimental results shows that the proposed RPSViT achieves a mean accuracy of 96.97 ± 1.81%, sensitivity of 96.06 ± 2.38%, specificity of 100.00 ± 0.00%, and mean AUC of 0.9989 ± 0.0015. Additionally, the framework attainsan F1-score of 0.9798 ± 0.0125, Matthews correlation coefficient (MCC) of 0.9225 ± 0.0414, Cohen’s kappa coefficient of 0.9188 ± 0.0448, average precision of 0.9997 ± 0.0004, and Jaccard index of  \n0.9606 ± 0.0238. These RPSViT performance results shows that it effectively bridges advanced transformer architectures with practical medical diagnostics, providing more accurate and automated tools in pancreatic oncology.  \nKeywords Vision transformer, Deep learning, Computed tomography, Pancreatic cancer, Rotary positional embedding, Siamese transformer encoder  \nEarly detection of cancer in human organs is a challenging and critical issue for patient survival, particularly for organs with complex structures and variable sizes, such as the pancreas. Pancreatic cancer is a serious disease that originates in pancreas located behind the stomach that aids in digestion and blood sugar regulation. It commonly begins in the duct cells (pancreatic ductal adenocarcinoma, or PDAC) and is often referred to as a“silent” cancer because it shows no clear symptoms in the early stages. As it progresses, symptoms may include abdominal or back pain, weight loss, loss of appetite, jaundice, fatigue, and sometimes new-onset diabetes. It is particularly dangerous because it is often diagnosed late due to the lack of routine screening and its deep location in the body. Risk factors include smoking, long-term diabetes, chronic pancreatitis, obesity, family history, and certain genetic mutations, although it can also occur without clear causes. The pancreatic tumor diagnosis involves imaging tests (CT, MRI, ultrasound, PET), endoscopic ultrasound (EUS) with biopsy, and blood tests for tumor markers. A most accurate diagnosis requires a tissue biopsy to observe the cells under a microscope. Imaging aids to visualize the tumor, while a biopsy confirms if it’s cancerous and blood tests can provide additional clues. A deep-learning network designed for pancreas and tumor segmentation called, Mean Max Pooling U Net (MMPI-Net) was proposed in1 to improving accuracy while minimizing model size. Here,  \n1Department of ECE, Bannari amman Institute of Technology, Sathyamangalam, Erode, Tamil Nadu,","cbCaiqDLkDrr9AOo","https://ap.wps.com/l/cbCaiqDLkDrr9AOo","pdf",4908561,24,"English","# Overview\n## Proposed RPSViT framework\n## Experimental setup and datasets\n## Performance results\n## Clinical background and diagnosis workflow","[{\"question\":\"What problem does the RPSViT paper address in pancreatic CT imaging?\",\"answer\":\"It targets accurate pancreatic tumor detection while addressing limitations of prior methods, especially high computational complexity and difficulty reducing false negatives for malignant lesions.\"},{\"question\":\"How does RPSViT model spatial information in CT images?\",\"answer\":\"RPSViT uses a patch-based tokenization with linear patch embedding and adds rotary positional embedding to capture spatial relationships for improved tumor localization.\"},{\"question\":\"Which data sources and evaluation method were used to test the model?\",\"answer\":\"The model was trained and evaluated on Pancreatic-CT scan images from TCIA and MSD datasets using 5-fold cross-validation.\"}]","Pancreatic tumor detection in computed tomography images through a rotary positional siamese vision transformer | PDF",1790089527,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/9ad33f80719896aaf3825b8e80f36319.webp",983,1291,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/d883abeb9095a89b2f0bc229f25b9768.webp",982,1290,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/8d46ccee2fa9eacf48d11fe2949b052c.webp",981,1289,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/221dc83bcb046fd3a5628754c0b96d5d.webp",980,1287]