[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-639716-105":59,"doc-detail-639716-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","panasonic-tr-1030p-service-manual","Panasonic TR-1030P Service Manual","","Panasonic TR-1030P service manual guidance for servicing technicians, centered on safe handling of high-voltage television circuitry. It provides device specifications including power source and consumption, tuning ranges, intermediate frequencies, semiconductor counts, audio output, and picture tube details. The safety section includes isolation transformer guidance, lead dress and short-circuit replacement rules, protective component verification, B+ resistance checks, leakage current cold/hot test procedures, and X-radiation warnings with high-voltage measurement limits to prevent shock and premature component failure.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/panasonic-tr-1030p-service-manual/639716/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/panasonic-tr-1030p-service-manual/639716.png","ImageObject",300,407,{"name":92,"@type":93},"Chumphorn","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-26","2026-10-22",true,{"@type":102,"interactionType":103,"userInteractionCount":8},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What safety steps must be followed before servicing the TR-1030P chassis?","Question",{"text":112,"@type":113},"Technicians must read and follow the safety precautions and important safety notice. Use attention to original lead dress in high-voltage circuits, verify protective devices after servicing, and discharge the anode of the picture tube before handling the tube.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How is leakage current measured in the cold check procedure?",{"text":117,"@type":113},"Unplug the AC cord and jumper the plug prongs, then turn the receiver on and measure resistance between the jumpered AC plug and exposed metallic parts. Parts with a return path to chassis should read 1.8 megohm to 4 megohms; parts without a return path must read infinity.",{"name":119,"@type":110,"acceptedAnswer":120},"What high-voltage limits and X-radiation precautions are specified?",{"text":121,"@type":113},"The high voltage meter should indicate a nominal 4.7 kV and a maximum 6.0 kV. If the upper indication exceeds the maximum, immediate service is required, and the specified picture tube must be used to prevent X-radiation.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},639716,1793051638,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":52,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144},2336475401981,"https://ap-avatar.wpscdn.com/avatar/22000c94efd8d5204d?x-image-process=image/resize,m_fixed,w_180,h_180&k=1786935347598174694","ORDER NO.FTD83090268C1Service Manual  \nThe Service Technician is required to read and follow the \"Safety Precautions\"and \"Important Safety Notice\"in this Service Manual.  \n# SPECIFICATIONS:\n\nPower Source:  \nAC:120V,60Hz.DC:6V  \nPower Consumption:  \nAC:4.5W  \nDC:1.8W  \nAntenna Impedance:  \nUHF/VHF Monopole  \nAntenna.75Ω,Unbalanced type.  \nReceiving Channel:  \nU.S.A.Standard  \nVHF:   2-13  \nUHF:  14-83  \nIntermediate  \nFrequency:  \nVideo:45.75MHz  \nSound:41.25MHz  \nIntegrated Circuits:  \n5 IC's  \nSemiconductor:  \n13 Transistors  \n23 Diodes  \nAudio Output:  \n120mW Maximum (at 1000Hz)  \nNominal Anode  \nVoltage:  \n4.7kV(Zero Beam Current)  \nPicture Tube:  \n40CB4M 1.536°Deflection  \nSpeaker:  \n1-3/8 inches,8Ω,Round type.  \nMatsushita Enginnering  \nand Service Company  \nSecaucus.New Jersey 07094  \nBlack and White Television  \nTR-1030P  \nChassis No.M10Chassis Family No.1M10  \nAutomatic Circuit:Peak Automatic Gain ControlSaw-Tooth Automatic FrequencyControl  \nAutomatic Voltage Regulator  \nDimensions:  \nHeight:1-1/2 inches (38mm)  \nWidth:3-1/8 inches (79mm)  \nDepth:5-15/16 inches(151mm)  \nWeight:  \n0.81 Ibs.(0.37kg)without dry Battery  \nStandard Accessories:AC Adaptor(TY-AC39P or TY-AC46P)Earphone(TNQ8955)Car Battery Cord (TSX8366B)Rechargeable Battery(TY-391P)Lens Hood(TKK800574-6)  \nOptional Accessorise:Car Battery Cord (TY-NC32P)Specifications are subject to change without notice.  \nPanasonic Sales Company,Division of Matsushita Electricof Puerto Rico,Inc.Ave.65 de Infanteria.KM 9.7Victoria Industrial ParkCarolina,Puerto Rico 00630  \nPanasonic Hawaii,Inc.320Waiakamilo Road,Honolulu.Hawaii 96817  \nTR-1030P  \n# SAFETY PRECAUTIONS\n\nGENERAL GUIDELINES  \n1.It is advisable to insert an isolation transformer betweenthe television set and the AC power line before servicingthe chassis.  \n2.In servicing,pay attention to the original lead dress,especially in the high voltage circuit.If a short circuit isfound,replace all parts which have been overheated as aresult the short circuit.  \n3.After servicing,observe that all the protective devicessuch as insulation barriers,insulation papers,shields,isolation and R-C combinations,are properly installed.  \n4.Before turning the receiver on,check the resistancebetween the B+line and chassis ground.Connect O sideof an ohmmeter to B+line and +side to ground.Eachline should have more resistance than specified below.  \n\n| B+line   | Minimum Resistance   |\n| --- | --- |\n| 4.8V   | 600Ω   |\n\n5.When the TV set will not be used for a long period oftime,unplug the power cord from the AC line outlet.  \n6.Potentials as high as 4.7kV are present when this receiveris operating.Operation of the receiver without the rearcover on involves danger of shock.  \nServicing should not be attempted by anyone who is notthoroughly familiar with the precautions necessary whenworking on high-voltage equipment.Always dischargethe anode of the picture tube to the receiver chassisbefore handling the tube.  \n7.After servicing make the following leakage current checkto prevent the customer from undergoing shock hazard.  \n## LEAKAGE CURRENT COLD CHECK\n\n1.Unplug the AC cord and connect a jumper between thetwo prongs on the plug.  \n2.Turn the receiver power switch on.  \n3.Measure the resistance value with an ohmmeter betweenthe jumpered AC plug and each exposed metallic partsuch as screwheads,antennas,control shafts,handlebracket,etc.When the exposed metallic part has a returnpath to the chassis,the reading should be 1.8 megohm to4 megohms.When the exposed metal does not have areturn path to the chassis,the reading must be infinity.  \n4.Remove the jumper from the AC plug.  \nTHIS MODEL COMPL/ES WITH DHHS RULES 21 CFR SUBCHAPTER JAPPLICABLE AT DATE OF MANUFACTURE.  \n# LEAKAGE CURRENT HOT CHECK\n\n1.Plug the AC cord directly into the AC outlet.Do not usean isolation transformer during this check.  \n2.Connect a 1500 ohm,10 watt resistor,paralleled by a  \n0.15μF capacitor between each exposed metallic partand a good ground like a water pipe as s","cbCaiiD4uBeKm7wY","https://ap.wps.com/l/cbCaiiD4uBeKm7wY","pdf",2457857,"English","# SPECIFICATIONS:\n## Power Source\n## Power Consumption\n## Receiving Channel\n## Intermediate Frequency\n## Integrated Circuits and Semiconductors\n## Audio Output and Picture Tube\n## Dimensions and Weight\n# SAFETY PRECAUTIONS\n## GENERAL GUIDELINES\n## LEAKAGE CURRENT COLD CHECK\n## LEAKAGE CURRENT HOT CHECK\n## X-RADIATION\n# DISASSEMBLY INSTRUCTIONS-","[{\"question\":\"What safety steps must be followed before servicing the TR-1030P chassis?\",\"answer\":\"Technicians must read and follow the safety precautions and important safety notice. Use attention to original lead dress in high-voltage circuits, verify protective devices after servicing, and discharge the anode of the picture tube before handling the tube.\"},{\"question\":\"How is leakage current measured in the cold check procedure?\",\"answer\":\"Unplug the AC cord and jumper the plug prongs, then turn the receiver on and measure resistance between the jumpered AC plug and exposed metallic parts. Parts with a return path to chassis should read 1.8 megohm to 4 megohms; parts without a return path must read infinity.\"},{\"question\":\"What high-voltage limits and X-radiation precautions are specified?\",\"answer\":\"The high voltage meter should indicate a nominal 4.7 kV and a maximum 6.0 kV. If the upper indication exceeds the maximum, immediate service is required, and the specified picture tube must be used to prevent X-radiation.\"}]","Panasonic TR-1030P Service Manual | PDF",1792704973,25]