[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-203500-105":59,"doc-detail-203500-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","optim-frm-75-440-fixed-capacitor-with-rejection-reactance-p-7-code-r5y3a0","OPTIM FRM-75-440 - Fixed capacitor with rejection reactance p = 7 % - Code R5Y3A0","","OPTIM FRM-75-440 is a fixed capacitor bank with detuned filters designed for power compensation in motors and transformers under constant load, especially when the network contains a high harmonic content and resonance risk. It combines capacitor protection steps with NH-00 series high-rupture-power fuses or a circuit breaker option, includes waste filters tuned to 189 Hz to protect harmonics of order 5 or higher, and uses a thermostat trip at 90 °C. Electrical data include 440 V reinforcement, ±10% tolerance, and defined surge and overload performance, with IP 21 environmental protection.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/optim-frm-75-440-fixed-capacitor-with-rejection-reactance-p-7-code-r5y3a0/203500/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/optim-frm-75-440-fixed-capacitor-with-rejection-reactance-p-7-code-r5y3a0/203500.png","ImageObject",300,407,{"name":92,"@type":93},"Taylor Morgan","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-08","2026-09-04",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",11,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What is the main purpose of the OPTIM FRM-75-440 capacitor bank?","Question",{"text":113,"@type":114},"It is designed for power compensation in motors and transformers with constant load, where there is a high harmonic content and risk of resonance.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How does the device help manage harmonics and prevent resonance?",{"text":118,"@type":114},"Waste filters are tuned to 189 Hz to protect harmonics present in the network and avoid resonance phenomena with harmonics of order 5 or more.",{"name":120,"@type":111,"acceptedAnswer":121},"What protection features are included in the OPTIM FRM-75-440?",{"text":122,"@type":114},"It provides individual protection of each step using high-rupture-power NH-00 series fuses, and it incorporates a thermostat that disconnects the step if temperature exceeds 90 °C.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},203500,1790113740,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":19,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":52},1099523885336,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","Fixed capacitors with detuned reactor of P = 7%(fres=189 Hz), 50 Hz  \nPage 1 of 4  \nOPTIM FRM-75-440  \nOPTIM FRM-75-440, Fixed capacitor with armonic filter Code: R5Y3A0 .  \n> Cable section (mm2): 50  \n> kvar (400 V): 62  \n> kvar (440 V): 75  \n> Cut off power: 50 kA> Use voltage (V): 440  \nDescription  \nThe FRF / FRM Series capacitor banks with detuned filters have been designed for power compensation purposes in motors and transformers with a constant load level, a high content of harmonics and where there is a risk of resonance. Including:  \n FRF: general protection with NH-00 fuses with a high rupture power (HRP) for the capacitor.  \n FRM: general circuit breaker protection for the capacitor.  \nApplication  \nIts application is mainly based on the compensation of transformers and motors. In general, it is used for the compensation of installations under constant loads and where there is a high content of harmonics in the network.  \nCreation date: 04/09/2026-CIRCUTOR, SAU reserves the right to make technical changes or modify the content/images of this document without prior notice, in order to improve its reliability, functionality, design or for other reasons.  \nIt accepts no liability for any errors, inaccuracies or possible lack of information in this document.  \nPage 1 of 4  \nFixed capacitors with detuned reactor of P = 7%(fres=189 Hz), 50 Hz  \nPage 2 of 4  \n\n| | OPTIM FRM-75-440\u003Cbr>Fixed capacitor with rejection reactance p = 7 %\u003Cbr>Code: R5Y3A0 . |  |\n| --- | --- | --- |\n| Specifications |  |  |\n| Electrical characteristics |  |  |\n| Losses (W) | Dielectric: \u003C 0.2 W/kvar Total: \u003C 0.5 W/kvar |  |\n| Discharge resistance | 75 V / 3 min |  |\n| Surge | 21 % 8 h over 24 h 15 % up to 15 min over 24 hours 20 % up to 5 min over 24\u003Cbr>hours 30 % up to 1 min over 24 hours |  |\n| Reinforcement voltage | 440 V |  |\n| Tolerance C | ±10 % |  |\n| Mechanical characteristics |  |  |\n| Size (mm) width x height x depth | 650 x 1060 x 420 (mm) |  |\n| Thermal management | Natural or forced according to options |  |\n| Fastening | Vertical |  |\n| Weight (kg) | 96 |  |\n| Environmental characteristics |  |  |\n| Protection class |  | IP 21 |\n| Relative humidity (without condensation) |  | 80% |\n| Current measurement circuit |  |  |\n| Permanent overload | 1,3 In |  |\n| Standards |  |  |\n| Electrical safety, Maximum height (m) | 2000 m |  |\n| Features / performance |  |  |\n| Components CF Capacitor General tripolar circuit breaker for protection. Waste filters tuned to\u003Cbr>189 Hz to protect harmonics present in the network and avoid resonance phenomena with harmonics of order 5 or more. It incorporates a thermostat to disconnect the step in case of high temperature (90 ºC) . |  |  |\n| Protection |  |  |\n| Element | Individual protection of each step with fuses with high rupture power (HRP) .\u003Cbr>NH-00 Series. |  |\n\nOPTIM FRM  \nFixed capacitors with detuned reactor of P = 7%(fres=189 Hz), 50 Hz  \n\n| CODE | TYPE | kvar (400 V) | kvar (440 V) | Cable section (mm2) |\n| --- | --- | --- | --- | --- |\n| OPTIM FRM, molded case circuit breaker protection, 440 V, 50 Hz |  |  |  |  |\n| R5Y350 . | OPTIM FRM-25-440 | 21 | 25 | 10 |\n\nCreation date: 04/09/2026-CIRCUTOR, SAU reserves the right to make technical changes or modify the content/images of this document without prior notice, in order to improve its reliability, functionality, design or for other reasons.  \nIt accepts no liability for any errors, inaccuracies or possible lack of information in this document.  \nPage 2 of 4  \nFixed capacitors with detuned reactor of P = 7%(fres=189 Hz), 50 Hz  \nPage 3 of 4  \n\n| |  | OPTIM FRM-75-440\u003Cbr>Fixed capacitor with rejection reactance p = 7 %\u003Cbr>Code: R5Y3A0 . |  |  |  |\n| --- | --- | --- | --- | --- | --- |\n| CODE | TYPE |  | kvar (400 V) | kvar (440 V) | Cable section (mm2) |\n| R5Y370 . | OPTIM FRM-37,5-440 |  | 31 | 37,5 | 16 |\n| R5Y380 . | OPTIM FRM-50-440 |  | 42 | 50 | 25 |\n| R5Y390 . | OPTIM FRM-60-440 |  | 50 | 60 | 35 |\n| R5Y3A0 . | OPTIM FRM-75-440 |  | 62","cbCaitGHwZvP6Mdi","https://ap.wps.com/l/cbCaitGHwZvP6Mdi","pdf",331979,"English","# Specifications\n## Electrical characteristics\n## Mechanical characteristics\n## Environmental characteristics\n## Standards\n## Features / performance\n## Protection\n# Application\n## Typical use cases","[{\"question\":\"What is the main purpose of the OPTIM FRM-75-440 capacitor bank?\",\"answer\":\"It is designed for power compensation in motors and transformers with constant load, where there is a high harmonic content and risk of resonance.\"},{\"question\":\"How does the device help manage harmonics and prevent resonance?\",\"answer\":\"Waste filters are tuned to 189 Hz to protect harmonics present in the network and avoid resonance phenomena with harmonics of order 5 or more.\"},{\"question\":\"What protection features are included in the OPTIM FRM-75-440?\",\"answer\":\"It provides individual protection of each step using high-rupture-power NH-00 series fuses, and it incorporates a thermostat that disconnects the step if temperature exceeds 90 °C.\"}]","OPTIM FRM-75-440 - Fixed capacitor with rejection reactance p = 7 % - Code R5Y3A0 | PDF",1788561534]