[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-640114-105":59,"doc-detail-640114-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","operators-manual-with-maintenance-information-original-instructions-fourth-edition-fourth-printing-part-no-145356","Operator's Manual with Maintenance Information - Original Instructions Fourth Edition - Fourth Printing - Part No. 145356","","Operator’s manual for a Genie AWP Super Series machine (Part No. 145356) providing safety rules and operational guidance. It emphasizes trained and authorized personnel only, mandatory pre-operation inspection and function tests, and compliance with manufacturer, employer, and governmental regulations. Includes critical warnings for electrocution hazards, required minimum safe approach distances by voltage, and tip-over/handling hazards covering leveling, outriggers, platform raising limits, transport restrictions, and allowable forces under ANSI/CSA and CE/AUS standards.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/operators-manual-with-maintenance-information-original-instructions-fourth-edition-fourth-printing-part-no-145356/640114/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/operators-manual-with-maintenance-information-original-instructions-fourth-edition-fourth-printing-part-no-145356/640114.png","ImageObject",300,407,{"name":92,"@type":93},"GGG","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-26","2026-10-22",true,{"@type":102,"interactionType":103,"userInteractionCount":14},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Who is allowed to operate the machine described in this manual?","Question",{"text":112,"@type":113},"Only trained and authorized personnel may operate the machine. The operator must learn, practice, and obey the safety and operating instructions in the manual.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What should be done before using the machine?",{"text":117,"@type":113},"Perform a pre-operation inspection and always run function tests prior to use. Also inspect the workplace before operating.",{"name":119,"@type":110,"acceptedAnswer":120},"How does the manual address electrocution and safe distances from power lines?",{"text":121,"@type":113},"The machine is not electrically insulated, and operators must keep away if it contacts energized lines. Maintain minimum safe approach distances based on voltage and account for platform movement and line sway/sag.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},640114,1793051659,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":14,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145},962093532725,"https://ap-avatar.wpscdn.com/davatar_276721f389ce27ea32af1340a28f341c","Operator ’s Manual  \nwith Maintenance Information  \nOriginal Instructions Fourth Edition  \nFourth Printing Part No . 145356  \n\n| Important\u003Cbr>Read, understand and obey these safety rules and operating instructions before operating this machine. Only trained and authorized personnel shall be permitted to operate this machine. This manual should be considered a permanent part of your machine and should remain with the machine at all times. If you have any questions, call Genie. |\n| --- |\n| Contents\u003Cbr>Page\u003Cbr>Safety Rules .............................................................. 1\u003Cbr>Controls ..................................................................... 8\u003Cbr>Legend ...................................................................... 9\u003Cbr>Pre-operation Inspection ........................................... 10\u003Cbr>Maintenance ............................................................. 12\u003Cbr>Function Tests .......................................................... 15\u003Cbr>Workplace Inspection ............................................... 18\u003Cbr>Operating Instructions .............................................. 19\u003Cbr>Battery Charging Instructions ................................... 21\u003Cbr>Transport Instructions ............................................... 22\u003Cbr>Tilt-back Operation Instructions ................................ 25\u003Cbr>Decals ...................................................................... 28\u003Cbr>Specifications ........................................................... 32 |\n\nContact us:  \nInternet: [http://www.genielift.com](http://www.genielift.com)  \n[e-mail: awp.techpub@terex.com](e-mail: awp.techpub@terex.com)  \nGenie AWP Super Series Part No. 145356  \nSafety Rules  \nDanger  \nFailure to obey the instructions and safety rules in this manual will cause death or serious injury.  \nDo Not Operate Unless:  \n You learn and practice the principles of safe machine operation contained in this operator's manual.  \n1 Avoid hazardous situations.  \nKnow and understand the safety rules before going on to the next section.  \n2 Always perform a pre-operation inspection.  \n3 Always perform function tests prior to use.  \n4 Inspect the workplace.  \n5 Only use the machine as it was intended.  \n You read, understand and obey the manufacturer's instructions and safety rules—safety and operator's manuals and machine decals.  \n You read, understand and obey employer's safety rules and worksite regulations.  \n You read, understand and obey all applicable governmental regulations.  \n You are properly trained to safely operate the machine.  \n The first time this machine is set up for use, a breather cap is installed. See Pre-operation Inspection section.  \nSAFETY RULES  \nElectrocution Hazards  \nThis machine, even with an optional fiberglass platform, is not electrically insulated and will not provide protection from contact with or proximity to electrical current.  \nKeep away from the machine if it contacts energized power lines or becomes electrically charged. Personnel on the ground or in the platform must not touch or operate the machine until energized power lines are shut off.  \nMaintain safe distances from electrical power lines and apparatus in accordance with applicable governmental regulations and the following chart.  \n\n| Voltage | Minimum Safe Approach Distance |  |\n| --- | --- | --- |\n| Phase to Phase | Feet | Meters |\n| 0 to 300V | Avoid | Contact |\n| 300V to 50KV | 10 | 3.05 |\n| 50KV to 200KV | 15 | 4.60 |\n| 200KV to 350KV | 20 | 6.10 |\n| 350KV to 500KV | 25 | 7.62 |\n| 500KV to 750KV | 35 | 10.67 |\n| 750KV to 1000KV | 45 | 13.72 |\n\nAllow for platform movement, electrical line sway or sag and movement due to strong or gusty winds.  \nDo not use the machine as a ground for welding.  \nDo not operate an AC powered machine or a DC battery charger unless using a 3-wire grounded extension cord connected to a grounded AC circuit. Do not alter or disable 3-wire grounded plugs.  \nTip-over Hazards  \nDo not raise the","cbCaii8yIpneeu46","https://ap.wps.com/l/cbCaii8yIpneeu46","pdf",1383074,37,"English","# Safety Rules\n## Electrocution Hazards\n## Tip-over Hazards\n# Controls\n# Pre-operation Inspection\n# Maintenance\n# Function Tests\n# Workplace Inspection\n# Operating Instructions\n# Battery Charging Instructions\n# Transport Instructions\n# Tilt-back Operation Instructions\n# Decals\n# Specifications","[{\"question\":\"Who is allowed to operate the machine described in this manual?\",\"answer\":\"Only trained and authorized personnel may operate the machine. The operator must learn, practice, and obey the safety and operating instructions in the manual.\"},{\"question\":\"What should be done before using the machine?\",\"answer\":\"Perform a pre-operation inspection and always run function tests prior to use. Also inspect the workplace before operating.\"},{\"question\":\"How does the manual address electrocution and safe distances from power lines?\",\"answer\":\"The machine is not electrically insulated, and operators must keep away if it contacts energized lines. Maintain minimum safe approach distances based on voltage and account for platform movement and line sway/sag.\"}]","Operator's Manual with Maintenance Information - Original Instructions Fourth Edition - Fourth Printing - Part No. 145356 | PDF",1792707909,93]