[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-651603-105":59,"doc-detail-651603-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","operation-and-maintenance-manual-for-dams-may-26-2019","Operation and Maintenance Manual for Dams - May 26, 2019","","Operation and Maintenance Manual for Dams from the New Mexico Office of the State Engineer (Dam Safety Bureau) explains why dam owners must run safe operations, extend asset life, protect the environment, and meet legal and social obligations. It outlines an O&M program’s core phases and the planning-focused scope of the manual, including required updates and regulatory basis. The document provides an example outline covering introduction, operation procedures and recordkeeping, and instrumentation monitoring with suggested frequencies, personnel roles, and supporting forms.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/operation-and-maintenance-manual-for-dams-may-26-2019/651603/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/operation-and-maintenance-manual-for-dams-may-26-2019/651603.png","ImageObject",300,407,{"name":92,"@type":93},"vwvw","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-10","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What are the goals of an O&M program for dams?","Question",{"text":112,"@type":113},"The goals are to ensure safe dam operation, extend dam life and intended purpose, protect the environment and the owner’s investment, protect the dam operator, promote cost-efficient operations, and meet legal and social obligations.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What phases does an effective O&M program include?",{"text":117,"@type":113},"An effective O&M program involves three phases: planning, implementation, and evaluation.",{"name":119,"@type":110,"acceptedAnswer":120},"What typical items and frequencies are suggested for operation and instrumentation?",{"text":121,"@type":113},"Operation includes reservoir operation instructions and outlet works procedures, with example operation frequencies such as fully cycling valves at least once per year or twice per year. Instrumentation monitoring lists items like reservoir level and toe drains with suggested monthly frequencies and identifies responsible personnel and required forms.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},651603,1793114746,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":24,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":144,"preview_page_count":4},3985747874149,"https://ap-avatar.wpscdn.com/avatar/3a001161165b4dc3d9e?x-image-process=image/resize,m_fixed,w_180,h_180&k=1790129441039064114","NEW MEXICO OFFICE OF THE STATE ENGINEER  \nDam Safety Bureau  \nOperation and Maintenance Manual for Dams May 26, 2019  \nAn Operation and Maintenance (O&M) Program is critical for protecting the dam, downstream communities and personnel that work at the dam. The Goals of an O&M Program are to help dam owners to:  \n• ensure the safe operation of the dam,  \n• extend the life and achieve the intended purpose of the dam,  \n• protect the environment and owner's investment,  \n• protect the dam operator,  \n• promote cost-efficient operation, and  \n• meet legal and social obligations  \nAn effective O&M Program involves 3 phases: planning, implementation and evaluation. The O&M Manual addresses the planning phase of an owner's Operation and Maintenance Program. It is recognized that an owner must implement the operation and maintenance activity and evaluate the effectiveness of the activity and revise as necessary. Therefore, it is recognized that an O&M Program must be reviewed periodically and updated as needed to meet the goals of an effective O&M Program. Updates must be submitted to the OSE Dam Safety Bureau for review and approval.  \nO&M Manual requirements for dams are cited in the Rules and Regulations Governing Dam Design, Construction and Dam Safety, which were filed with the New Mexico State Record Center as Title 19, Chapter 25, Part 12 of the New Mexico Administrative Code (19.25.12 NMAC) . Section 17 of 19.25.12 NMAC states that owners of dams classified as high or significant hazard potential shall prepare, maintain and adhere to an operation and maintenance manual.  \nListed below is an example outline of areas that should be addressed in the O&M Manual depending on the type of dam and purpose. The outline suggests frequencies for various activities. A range of values is provided in recognition that water storage dams have different O&M needs compared to normally dry flood control dams. In addition, appurtenances are operated under varying loading conditions and inspection frequency must be appropriate for the operating conditions.  \nCertifications for the dam owner and the engineer that prepares the O&M Manual and State Engineer acceptance are required at the beginning of the document. The O&M Manual should be submitted in a 3-ring Binder to facilitate updates. Dates in the header or footer of each page will keep track of changes in the O&M Manual along with a summary in the Appendix. Please refer to the OSE paper titled \"Technical Reports for Dams\" to ensure the O&M Manual is presented in a well organized document.  \nFor additional information on developing and organizing an O&M Program please refer to Training Aids for Dam Safety (TADS) Module \"How to organize an O&M Program\".  \nNew Mexico Office of the State Engineer Operation and Maintenance Manuals for Dams  \nMay 26, 2019 Page 2 of 5  \nI. INTRODUCTION-State or list pertinent facts about the dam and reservoir. Construction drawings must be included in the Appendix. Typical items to address are:  \na. Location  \nb. Access  \nc. Purpose  \nd. Description  \ne. Table of Properties  \nf. History of Construction  \ng. History of Repairs  \nh. History of Performance  \nII. OPERATION-This section should indicate who, how frequent, and what is involved in  \noperating the dam. Maintaining records of operation activities is also required. Titles rather than individuals may be identified. Give a brief but complete description of all operation procedures. Specific procedures for operation of mechanical equipment such as valves could be included. Emergency operation procedures in this section must be consistent with the procedures in the Emergency Action Plan (EAP) . Typical items to address are:  \na. Reservoir Operation Instructions  \ni. Storage Allocations  \nii. Spillway Design Flood Water Level  \niii. First Fill Criteria and Monitoring Requirements  \niv. Maximum Drawdown Rate and corresponding Outlet Discharge for both emergency and non-emergency conditions. If outlet discharge will ca","cbCaiqj4rQ0mqBcz","https://ap.wps.com/l/cbCaiqj4rQ0mqBcz","pdf",89310,"English","# INTRODUCTION\n## OPERATION\n## INSTRUMENTATION","[{\"question\":\"What are the goals of an O\\u0026M program for dams?\",\"answer\":\"The goals are to ensure safe dam operation, extend dam life and intended purpose, protect the environment and the owner’s investment, protect the dam operator, promote cost-efficient operations, and meet legal and social obligations.\"},{\"question\":\"What phases does an effective O\\u0026M program include?\",\"answer\":\"An effective O\\u0026M program involves three phases: planning, implementation, and evaluation.\"},{\"question\":\"What typical items and frequencies are suggested for operation and instrumentation?\",\"answer\":\"Operation includes reservoir operation instructions and outlet works procedures, with example operation frequencies such as fully cycling valves at least once per year or twice per year. Instrumentation monitoring lists items like reservoir level and toe drains with suggested monthly frequencies and identifies responsible personnel and required forms.\"}]","Operation and Maintenance Manual for Dams - May 26, 2019 | PDF",1792875499,13]