[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-652367-105":59,"doc-detail-652367-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","operating-instructions-parts-manual-heavy-duty-in-line-gearmotors-shaded-pole-split-phase-models-enclosed-double-triple-reduction","OPERATING INSTRUCTIONS & PARTS MANUAL - HEAVY DUTY, IN-LINE GEARMOTORS - SHaded Pole & Split Phase Models - Enclosed-Double & Triple Reduction","","Dayton heavy duty, in-line gearmotors operating instructions and parts manual covering shaded pole and split phase motor models with enclosed double and triple reduction configurations. The manual describes construction features such as die-cast aluminum housing, precision gear alignment, helical high-speed input stages, heat-treated spur gears, and anti-friction needle bearings. It provides installation guidance, wiring and grounding requirements using NEC references, rotation reversing instructions, safety warnings, and a wire selection guide and load factor chart.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/operating-instructions-parts-manual-heavy-duty-in-line-gearmotors-shaded-pole-split-phase-models-enclosed-double-triple-reduction/652367/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/operating-instructions-parts-manual-heavy-duty-in-line-gearmotors-shaded-pole-split-phase-models-enclosed-double-triple-reduction/652367.png","ImageObject",300,407,{"name":92,"@type":93},"Angel","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-24",true,{"@type":102,"interactionType":103,"userInteractionCount":8},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What safety precautions are required before installing or servicing the gearmotor?","Question",{"text":112,"@type":113},"Disconnect power before installing or servicing. Ensure the power disconnect point is locked in the open position and tagged to prevent unexpected application of power.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How can motor rotation be reversed for split phase units?",{"text":117,"@type":113},"For split phase units, reverse rotation by interchanging the red and black leads, following the wiring diagram shown in the manual.",{"name":119,"@type":110,"acceptedAnswer":120},"Where should the gearmotor be installed and how should it be wired and grounded?",{"text":121,"@type":113},"Install in a clean and dry area with access to adequate cooling air, and protect it from weather if outdoors. Use wiring connections that comply with NEC and local codes, and securely ground the motor frame with a separate ground wire.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},652367,1792880016,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":8,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":19,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":129,"read_time":52},687207412472,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.  \nFigure 1  \nDescription  \nThe Dayton heavy duty,in-line gearmotor can bemounted in any position.Construction is of highstrength aluminum die cast alloy.Housing andcover are doweled and precision bored for accurategear alignment.Gearing consists of helical highspeed input stage for smooth operation.Highstrength steel spur gears at subsequent stages givemaximum load carrying capacity.All gears andpinion are heat treated for maximum durabilityunder rated torque.Anti-friction needle bearings ofhigh load carrying capacity are used at all positionsfor high efficiency and dependability.The motor isequipped with ball bearings and electrical and me-chanical construction varies depending on type ofmotor(see table).Motors are designed and con·structed for maximum reliability.  \n# OPERATING INSTRUCTIONS &PARTS MANUAL\n\nHEAVY DUTY,IN-LINE GEARMOTORSSHADED POLE &SPLIT PHASE MODELSENCLOSED-DOUBLE &TRIPLE REDUCTION  \nFORM  \n6S1716  \n02109  \nDAYTON ELECTRIC MANUFACTURING co.CHiCAGO 60648  \n0982/33V5  \nREADINSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL,OPERATE OR SERVICE THE DAYTONGEARMOTOR.  \nDimensions  \n-2  \nFigure 2—Dimenslons  \n\n| Type   | RPM   | TE/FC  \u003Cbr>C  \u003Cbr>D   |\n| --- | --- | --- |\n| Shaded Pole   | 4.6  \u003Cbr>.13.5  \u003Cbr>3067.5   | 329/32  \u003Cbr>9V4“  \u003Cbr>9%”  \u003Cbr>329/5”  \u003Cbr>3²9/52”  \u003Cbr>9V”   |\n| Spllt Phase   | 13.6,30.  \u003Cbr>67.5100   | 329/a2\"  \u003Cbr>1013/16“   |\n\n## Specifications\n\n\n| Model   | Gear  \u003Cbr>Ratlo   | FD/L  \u003Cbr>Speod  \u003Cbr>RPM   | FIL  \u003Cbr>Torque  \u003Cbr>In./Lbs.   | Input  \u003Cbr>Motor  \u003Cbr>HP   | Motor  \u003Cbr>F/L  \u003Cbr>Amps   | Motor  \u003Cbr>Enclpsuro   | Reduotlon   | Motor  \u003Cbr>Type   |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| 3M326A  \u003Cbr>3M327A  \u003Cbr>3M328A  \u003Cbr>3M329A  \u003Cbr>3M330A  \u003Cbr>6K303A  \u003Cbr>22017A  \u003Cbr>22018A  \u003Cbr>22041A   | 396:1  \u003Cbr>265:1  \u003Cbr>118:1  \u003Cbr>53:1  \u003Cbr>23:1  \u003Cbr>53:1  \u003Cbr>118:1  \u003Cbr>23:1  \u003Cbr>17:1   | 4.0  \u003Cbr>6.0  \u003Cbr>13.5  \u003Cbr>30.0  \u003Cbr>67.5  \u003Cbr>30.0  \u003Cbr>13.5  \u003Cbr>67.5  \u003Cbr>100.0   | 200  \u003Cbr>208  \u003Cbr>125  \u003Cbr>55  \u003Cbr>125  \u003Cbr>200  \u003Cbr>55  \u003Cbr>38   | 1/40  \u003Cbr>1/40  \u003Cbr>1/20  \u003Cbr>1/15  \u003Cbr>1/15  \u003Cbr>1/15  \u003Cbr>1/15  \u003Cbr>1/15  \u003Cbr>1/15   | 1.4  \u003Cbr>1.4  \u003Cbr>1.6  \u003Cbr>2.2  \u003Cbr>2.2  \u003Cbr>1.7  \u003Cbr>1.7  \u003Cbr>.7  \u003Cbr>1.7   | TEFQ  \u003Cbr>TEFC  \u003Cbr>TEFC  \u003Cbr>TEFC  \u003Cbr>TEFC  \u003Cbr>TEFC  \u003Cbr>TEFC  \u003Cbr>TEFC  \u003Cbr>TEFC   | Triple  \u003Cbr>Tlple  \u003Cbr>Triple“  \u003Cbr>Double  \u003Cbr>Double  \u003Cbr>Double  \u003Cbr>Triple  \u003Cbr>Double  \u003Cbr>Double   | Shaded Pole  \u003Cbr>Shaded Pole  \u003Cbr>Shaded Pole  \u003Cbr>Shaded Pole  \u003Cbr>Shaded Pole  \u003Cbr>Split Phase  \u003Cbr>Split Phase  \u003Cbr>Split Phase  \u003Cbr>Split Phase   |\n\nFORM 581714  \nWARNING:DO NOT INSTALL IN AN EXPLOSIVEATMOSPHERE  \nCAUTION:When an installatlon involves aholdingor overhauling application(such asa holst or con-veyor),aseparate magnetic brake or other lockingdevice should be used.Do nol depend on gear tric-tion to hold the load.  \n1.Gearmotor should be located in a clean and dryarea with access to adequate cooling air supply.If installation is outdoors,make certain that theunit is protected from the weather.  \n2.Mount gearmotor to a rigid surface,preferablymetallic,using largest bolis shat will fit throughthe base holes.  \n3.Wiring connections:  \nDiagrams below are for split phase units only,Models 6K303A,2Z817A,2Z818A,&2Z841A.  \nTo reverse rotation interchange red and black leadsEigure 3-Wiring Diagran  \nNOTE:Motor is factory-wired for clockwjse(CW)rotation facing output shaft;should counterclock.wise(CCW)rolation be required,consult wiring dia-grams(Figure 3).  \na.All wiring and electrical connections must66mply with the NEC,and local electricalcodes in ellect.In particular,refer to NEC AP-ticle 430(Motors,Motor Circuits and Con-trollere).  \n2.Securely ground the molor by connecting a sep-arate ground wire to the bare metal of the motorframe,or other suitable means.Refer to NECarticle 250(grounding)for additionalinformation.  \n3.Always disconnect power source before workingon or near a motor or its connected load.If thepower disconnec","cbCaiopCp8QCdBpN","https://ap.wps.com/l/cbCaiopCp8QCdBpN","pdf",2287150,"English","# Operating Instructions & Parts Manual\n## Specifications\n## Installation\n## Wire Selection Guide\n## Load Factor Chart","[{\"question\":\"What safety precautions are required before installing or servicing the gearmotor?\",\"answer\":\"Disconnect power before installing or servicing. Ensure the power disconnect point is locked in the open position and tagged to prevent unexpected application of power.\"},{\"question\":\"How can motor rotation be reversed for split phase units?\",\"answer\":\"For split phase units, reverse rotation by interchanging the red and black leads, following the wiring diagram shown in the manual.\"},{\"question\":\"Where should the gearmotor be installed and how should it be wired and grounded?\",\"answer\":\"Install in a clean and dry area with access to adequate cooling air, and protect it from weather if outdoors. Use wiring connections that comply with NEC and local codes, and securely ground the motor frame with a separate ground wire.\"}]","OPERATING INSTRUCTIONS & PARTS MANUAL - HEAVY DUTY, IN-LINE GEARMOTORS - SHaded Pole & Split Phase Models - Enclosed-Double & Triple Reduction | PDF"]