[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-662777-105":59,"doc-detail-662777-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","operating-and-assembly-instruction-progressive-cavity-pump-issue-22-safety-description-installation-commissioning-maintenance","Operating and Assembly Instruction Progressive Cavity Pump - Issue 22 - Safety, Description, Installation, Commissioning, Maintenance","","Operating and assembly instruction for a seepex progressive cavity pump type BN 300-6L, including commission/job identification and issue date. Covers safety and warning concepts, qualification of personnel, protective equipment, foreseeable misuse, and normal usage, followed by pump description, mode of action, and construction. Provides technical data, transport and storage guidance, then detailed assembly and installation procedures. Includes commissioning and de-commissioning steps, maintenance measures, fault diagnosis and repair, dismantling/reassembly, and spare parts ordering.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/operating-and-assembly-instruction-progressive-cavity-pump-issue-22-safety-description-installation-commissioning-maintenance/662777/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/operating-and-assembly-instruction-progressive-cavity-pump-issue-22-safety-description-installation-commissioning-maintenance/662777.png","ImageObject",300,407,{"name":92,"@type":93},"RizkyPratama_92","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-30","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What safety information and warning notices are included before operating the pump?","Question",{"text":112,"@type":113},"The safety section covers general information, safety and warning notices, hazard signs and information signs, hazards that may arise, and required qualification of personnel. It also specifies protective equipment and safety/protective devices, along with foreseeable misuse and normal usage.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How should the progressive cavity pump be assembled and installed?",{"text":117,"@type":113},"Assembly/install guidance includes required tools and lifting gear, required space and stator construction dimensions, erection of the mounted pump, energy supply, and piping work. It also addresses suction and pressure connections, pipe dimensioning, residue-free and tension-free mounting.",{"name":119,"@type":110,"acceptedAnswer":120},"What maintenance, troubleshooting, and disassembly procedures are provided?",{"text":121,"@type":113},"Maintenance includes preventative measures, standstill of the pump, and lubrication details. Faults, causes and repair are covered, and the manual provides step-by-step procedures for pump dismantling/reassembly, rotating unit handling, holding band assembly, and mechanical seal dismantling and reassembly.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},662777,1793222398,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},962094243231,"https://ap-avatar.wpscdn.com/davatar_155a257f0dc6eb9ab79c44ca47cae57d","seepex INC.  \n511 Speedway Drive Enon, Ohio 45323  \nTel +1 (937) 864-71 50 Fax +1 (937) 864-71 57 [sales](sales@seepex.net)[@](sales@seepex.net)[seepex.net](sales@seepex.net)[ ](sales@seepex.net)[www.seepex.com](www.seepex.com)  \nOperating and Assembly Instruction Progressive Cavity Pump  \n24h Helpline:  \n[www.seepex.com](www.seepex.com)  \nCommission No . 800000-800001  \nJob\\#  \nXXX  \nType BN 300-6L  \n\n| \u003Cbr>\u003Cbr>Read instructions before beginning any work! |  | Always keep instructions handy on the worksite. |\n| --- | --- | --- |\n\nIssue: 22.07.2009  \nIndex  \n1 Safety................................................................................................................................................... 1  \n1.1 General Information  \n1.2 Safety and warning notices  \n1.2.1 Warning notices  \n1.2.2 Hazard signs  \n1.2.3 Information signs  \n1.3 Hazards that may arise from the machine  \n1.4 Qualification of personnel  \n1.5 Authorised persons  \n1.5.1 Tasks and information for the operating company / operator  \n1.5.2 Safety information for maintenance, technical service and assembly work  \n1.6 Equipment for personal protection  \n1.7 Safety and protective devices  \n1.8 Foreseeable misuse  \n1.9 Normal usage  \n1.10 Warranty  \n2 Description of the pump..................................................................................................................... 5  \n2.1 General description  \n2.2 Mode of action and conveying principle of seepex pumps  \n2.3 Construction  \n3 Technical Data .................................................................................................................................... 6  \n3.1 Data sheet ................................................................................................................................ 7  \n3.2 Characteristic line ................................................................................................................... 10  \n3.3 Declaration of conformity / Declaration by the manufacturer.................................................. 11  \n4 Transport........................................................................................................................................... 12  \n4.1 Safety  \n4.2 Transport  \n4.2.1 Dimensions and weight  \n4.2.2 Pictographs  \n4.2.3 Jacking points (AP) for lifting gear  \n4.2.4 Unpacking the machine  \n4.3 Intermediate storage / preserving  \n4.4 Disposal  \nIndex  \n5 Assembly / Installation ..................................................................................................................... 14  \n5.1 Mounting tools / lifting gear  \n5.2 Required space  \n5.2.1 Stator construction dimensions  \n5.3 Erection of the complete mounted pump  \n5.4 Energy supply to the seepex pump  \n5.5 Pipe work  \n5.5.1 Suction and pressure connection  \n5.5.2 Dimensioning of pipe work  \n5.5.3 Residue-free pipe work  \n5.5.4 Tension-free mounting  \n5.6 Dimsnesional Drawing............................................................................................................ 16  \n6 Commissioning / De-Commissioning............................................................................................. 17  \n6.1 Commissioning report ............................................................................................................ 17  \n6.2 Measures before commissioning............................................................................................ 18  \n6.2.1 Check pipe work  \n6.2.2 Protective devices on the pump  \n6.2.3 Electrical/hydraulic connections  \n6.2.4 Monitoring the direction of rotation  \n6.2.5 Auxiliary equipment – optional  \n6.3 Initial commissioning / re-commissioning  \n6.3.1 Avoiding dry running of the pump  \n6.3.2 Pressure on the suction and pressure connection  \n6.4 De-commissioning  \n6.4.1 Switching the pump off  \n6.4.2 Emptying the pump  \n6.4.3 Dismantling the pump  \n6.4.4 Preserving / placing pump in storage  \n7 Maintenance   22  \n7.1 Preventative measures  \n7.1.1 Stand","cbCaiaWgN6aycbtg","https://ap.wps.com/l/cbCaiaWgN6aycbtg","pdf",3727061,115,"English","# 1 Safety\n## 1.1 General Information\n## 1.2 Safety and warning notices\n## 1.3 Hazards that may arise from the machine\n## 1.4 Qualification of personnel\n## 1.5 Authorised persons\n## 1.6 Equipment for personal protection\n## 1.7 Safety and protective devices\n## 1.8 Foreseeable misuse\n## 1.9 Normal usage\n## 1.10 Warranty\n# 2 Description of the pump\n## 2.1 General description\n## 2.2 Mode of action and conveying principle of seepex pumps\n## 2.3 Construction\n# 3 Technical Data\n## 3.1 Data sheet\n## 3.2 Characteristic line\n## 3.3 Declaration of conformity / Declaration by the manufacturer\n# 4 Transport\n## 4.1 Safety\n## 4.2 Transport\n## 4.3 Intermediate storage / preserving\n## 4.4 Disposal\n# 5 Assembly / Installation\n## 5.1 Mounting tools / lifting gear\n## 5.2 Required space\n## 5.3 Erection of the complete mounted pump\n## 5.4 Energy supply to the seepex pump\n## 5.5 Pipe work\n# 6 Commissioning / De-Commissioning\n## 6.1 Commissioning report\n## 6.2 Measures before commissioning\n## 6.3 Initial commissioning / re-commissioning\n## 6.4 De-commissioning\n# 7 Maintenance\n## 7.1 Preventative measures\n## 7.2 Lubrication\n## 7.3 Technical service\n# 8 Faults, causes and repair\n# 9 Pump dismantling / reassembly\n## 9.1 Pump\n## 9.2 Rotating unit – individual parts\n## 9.3 Holding band-assembly\n## 9.4 Mechanical seal\n## 9.6 Sectional drawing shaft sealing\n# 10 Spare parts\n## 10.1 Order template for spare parts","[{\"question\":\"What safety information and warning notices are included before operating the pump?\",\"answer\":\"The safety section covers general information, safety and warning notices, hazard signs and information signs, hazards that may arise, and required qualification of personnel. It also specifies protective equipment and safety/protective devices, along with foreseeable misuse and normal usage.\"},{\"question\":\"How should the progressive cavity pump be assembled and installed?\",\"answer\":\"Assembly/install guidance includes required tools and lifting gear, required space and stator construction dimensions, erection of the mounted pump, energy supply, and piping work. It also addresses suction and pressure connections, pipe dimensioning, residue-free and tension-free mounting.\"},{\"question\":\"What maintenance, troubleshooting, and disassembly procedures are provided?\",\"answer\":\"Maintenance includes preventative measures, standstill of the pump, and lubrication details. Faults, causes and repair are covered, and the manual provides step-by-step procedures for pump dismantling/reassembly, rotating unit handling, holding band assembly, and mechanical seal dismantling and reassembly.\"}]","Operating and Assembly Instruction Progressive Cavity Pump - Issue 22 - Safety, Description, Installation, Commissioning, Maintenance | PDF",290]