[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-461141-105":59,"doc-detail-461141-en":135},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":128,"head_meta":130,"extra_data":132,"updated_unix":134},105,"en","one-year-impact-of-scleral-lens-wear-on-corneal-morphology-in-keratoconus-with-and-without-intracorneal-ring-segment","One-Year Impact of Scleral Lens Wear on Corneal Morphology in Keratoconus with and Without Intracorneal Ring Segment","","Purpose: Evaluate corneal thickness and anterior/posterior curvature changes after one year of scleral lens wear in keratoconus eyes and determine effects on visual performance. Methods: Sixty-five keratoconus subjects were assigned to groups with intrastromal corneal ring segments (KC-ICRS) or without ICRS (KC) and wore 16.5 mm scleral lenses for 8 h daily for 1 year. Results: Superior corneal thickness increased in KC-ICRS; curvature showed inferior steepening/superior flattening in KC and central/superior-nasal anterior flattening in KC-ICRS, with posterior central flattening and peripheral steepening. Visual acuity remained stable across visits and groups. Conclusions: Long-term scleral lens wear produced measurable, region-specific morphological changes that did not impair visual acuity, supporting safe sustained correction and emphasizing personalized fitting and monitoring.",{"@graph":69,"@context":127},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/one-year-impact-of-scleral-lens-wear-on-corneal-morphology-in-keratoconus-with-and-without-intracorneal-ring-segment/461141/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/one-year-impact-of-scleral-lens-wear-on-corneal-morphology-in-keratoconus-with-and-without-intracorneal-ring-segment/461141.png","ImageObject",300,407,{"name":92,"@type":93},"Cipher","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-02","2026-09-30",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",11,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119,123],{"name":110,"@type":111,"acceptedAnswer":112},"What was the study purpose regarding keratoconus and scleral lenses?","Question",{"text":113,"@type":114},"To evaluate one-year changes in corneal thickness and anterior/posterior corneal curvature after scleral lens wear in keratoconus eyes and assess their impact on visual performance.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How were participants grouped and what lens regimen was used?",{"text":118,"@type":114},"Sixty-five keratoconus subjects were divided into KC-ICRS (with intrastromal corneal ring segments) and KC (without ICRS). All wore 16.5 mm scleral lenses for 8 hours daily over one year.",{"name":120,"@type":111,"acceptedAnswer":121},"What morphological changes occurred after one year?",{"text":122,"@type":114},"Corneal thickness increased significantly in the superior region in KC-ICRS. Curvature changes differed by group, including inferior steepening and superior flattening in KC and central/superior-nasal anterior flattening in KC-ICRS, with posterior central flattening and peripheral steepening.",{"name":124,"@type":111,"acceptedAnswer":125},"Did visual acuity change over the study period?",{"text":126,"@type":114},"No. Visual acuity remained stable across all visits and across both groups, indicating that the observed morphological changes did not compromise visual acuity.","https://schema.org",{"og:url":83,"og:type":129,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":131,"canonical":83},"index,follow",{"doc_id":133,"site_id":62},461141,1790792635,{"code":4,"msg":5,"data":136},{"doc_id":133,"user_id":137,"nickname":92,"user_avatar":138,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":139,"file_id":140,"file_url":141,"file_type":142,"file_size":143,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":144,"language":145,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":146,"faqs":147,"seo_title":148,"seo_description":67,"update_tm":149,"read_time":150,"preview_page_count":19,"preview_urls":151},687208528416,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Article  \nOne-Year Impact of Scleral Lens Wear on Corneal Morphology in Keratoconus with and Without Intracorneal Ring Segment  \nMaría Serramito 1,2, *, Ana Privado-Aroco 1,2 and Gonzalo Carracedo 1,2  \nAcademic Editor: Rosario Caruso  \nReceived: 21 November 2025  \nRevised: 24 December 2025  \nAccepted: 29 December 2025  \nPublished: 4 January 2026  \nCopyright: © 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \n1 Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain; [aprivado@ucm.es](aprivado@ucm.es) (A.P.-A.); [jgcarrac@ucm.es](jgcarrac@ucm.es) (G.C.)  \n2 Ocupharm Research Group, Department of Optometry and Vision, Faculty of Optics and Optometry, Complutense University of Madrid, 28037 Madrid, Spain  \n* Correspondence: mserrami@ucm.es  \nHighlights  \nWhat are the main findings?  \n• Long-term scleral lens wear in keratoconus patients induces measurable changes in corneal morphology, including increased superior corneal thickness and regionspecific alterations in anterior and posterior curvature.  \n• These structural changes differ between patients with and without intrastromal corneal ring segments (ICRS), suggesting that baseline corneal architecture influences the biomechanical response to scleral lens wear.  \nWhat are the implications of the main findings?  \n• Despite corneal morphological changes, visual acuity remains stable over one year, indicating that scleral lenses provide sustained visual performance and may contribute to improving quality of life in keratoconus management.  \n• The observed changes highlight the need for the long-term monitoring of corneal parameters in scleral lens users, supporting personalized lens fitting strategies and advancing innovative approaches compared to foundational work in keratoconus care.  \nAbstract  \nPurpose: The purpose of this study is to evaluate changes in corneal thickness and anterior and posterior corneal curvature after one year of scleral lens wear in keratoconus eyes and to determine their impact on visual performance. Methods: Sixty-five keratoconus subjects were divided into two groups: with intrastromal corneal ring segments (KC-ICRS) and without ICRS (KC) . All participants wore 16.5 mm scleral lenses for 8 h daily over 1 year. Measurements included corneal thickness, anterior and posterior curvature, and highcontrast visual acuity assessed before and after lens wear. Results: Corneal thicknesses increased significantly in the superior region of the KC-ICRS group. In curvature analysis, the KC group showed inferior steepening and superior flattening, while the KC-ICRS group exhibited central and superior-nasal anterior flattening. Posterior curvature changes included central flattening and peripheral steepening. Visual acuity remained stable across all visits and groups. Conclusions: Long-term scleral lens wear induced measurable morphological changes, including increased superior corneal thickness and region-specific curvature alterations, which varied by ICRS presence. These changes did not compromise visual acuity, supporting scleral lenses as a safe and effective option for sustained vision correction in keratoconus. The findings highlight the importance of personalized fitting and monitoring strategies in clinical practice.  \nKeywords: contact lenses; cornea; corneal topography; keratoconus; visual acuity  \n1. Introduction  \nKeratoconus is a progressive corneal disease marked by thinning and irregular astigmatism, which often results in severe visual deterioration and impacts quality of life [1] . Prevalence reports for keratoconus vary widely, from 0.2 up to 4790 per 100,000 people, and incidence estimates range between 1.5 and 25 new cases annually per 100,000 [2] . The management of keratoconus has evolved from spectacles and corneal rigid gas-permeabl","cbCaiuXe5r4cabcS","https://ap.wps.com/l/cbCaiuXe5r4cabcS","pdf",2797372,15,"English","# Highlights\n## Main findings\n## Implications of the main findings\n# Abstract\n# Keywords\n# 1. Introduction","[{\"question\":\"What was the study purpose regarding keratoconus and scleral lenses?\",\"answer\":\"To evaluate one-year changes in corneal thickness and anterior/posterior corneal curvature after scleral lens wear in keratoconus eyes and assess their impact on visual performance.\"},{\"question\":\"How were participants grouped and what lens regimen was used?\",\"answer\":\"Sixty-five keratoconus subjects were divided into KC-ICRS (with intrastromal corneal ring segments) and KC (without ICRS). All wore 16.5 mm scleral lenses for 8 hours daily over one year.\"},{\"question\":\"What morphological changes occurred after one year?\",\"answer\":\"Corneal thickness increased significantly in the superior region in KC-ICRS. Curvature changes differed by group, including inferior steepening and superior flattening in KC and central/superior-nasal anterior flattening in KC-ICRS, with posterior central flattening and peripheral steepening.\"},{\"question\":\"Did visual acuity change over the study period?\",\"answer\":\"No. Visual acuity remained stable across all visits and across both groups, indicating that the observed morphological changes did not compromise visual acuity.\"}]","One-Year Impact of Scleral Lens Wear on Corneal Morphology in Keratoconus with and Without Intracorneal Ring Segment | PDF",1790760725,38,[152,156,160,164],{"page_no":8,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/5335a4c68adbe08b87b288cbecbe153e.webp",983,1390,{"page_no":14,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/b7ad9a12e58a2b7b89bbdb4c3450196a.webp",982,1388,{"page_no":81,"url":161,"width":162,"height":163},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/e311799dd010258650a7ebf39d51c00c.webp",981,1387,{"page_no":19,"url":165,"width":166,"height":167},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/b5eb2b7db114e6eaa37119fea49b96ed.webp",980,1385]