[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-366384-105":59,"doc-detail-366384-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","on-the-sensing-performance-improvement-in-spr-biosensor-using-zno-and-tmdcs-architecture-for-cancer-detection","On the sensing performance improvement in SPR biosensor using ZnO and TMDCs architecture for cancer detection","","Study presents an SPR biosensor architecture for highly sensitive, rapid detection of cancerous cells using 2D materials. Four layered sensor configurations are constructed with metal–dielectric coupling via a BK7 prism, using functional layers Ag, ZnO, Si3N4, and a sensing medium. To enhance light absorption and sensitivity, four TMDC materials (MoS2, MoSe2, WS2, WSe2) are incorporated. Angular interrogation and FEM simulations show the highest overall sensitivity for BK7/ZnO/Ag/Si3N4/WS2/sensing medium, achieving blood (Jurkat), cervical (HeLa), and skin (Basal) cancer detection. Results indicate promise for early, accurate cancer detection, with continued optimization needed for clinical translation and real-world deployment.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/on-the-sensing-performance-improvement-in-spr-biosensor-using-zno-and-tmdcs-architecture-for-cancer-detection/366384/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/on-the-sensing-performance-improvement-in-spr-biosensor-using-zno-and-tmdcs-architecture-for-cancer-detection/366384.png","ImageObject",300,407,{"name":92,"@type":93},"eBook King","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-28","2026-09-23",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",12,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What biosensor architecture is proposed for cancer detection?","Question",{"text":113,"@type":114},"The study proposes an SPR biosensor using a layered structure with ZnO, Si3N4, Ag, and a sensing medium coupled through a BK7 prism, enhanced with 2D TMDC materials.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"How do the 2D TMDC materials improve sensing performance?",{"text":118,"@type":114},"The sensor incorporates MoS2, MoSe2, WS2, and WSe2 to enhance light absorption capacity and increase overall sensitivity toward subtle refractive index changes.",{"name":120,"@type":111,"acceptedAnswer":121},"Which configuration shows the highest sensitivity and what is its performance for blood cancer detection?",{"text":122,"@type":114},"The BK7/ZnO/Ag/Si3N4/WS2/sensing medium configuration yields the highest overall sensitivity, with blood cancer detection from healthy cells reaching 342.14 deg/RIU and FOM of 124.86 RIU−1.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},366384,1790487212,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":19,"preview_urls":147},962088006270,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","[www. nature.com/scientificreports](www. nature.com/scientificreports)  \nOPEN  \nOn the sensing performance improvement in SPR biosensor using ZnO and TMDCs architecture for cancer detection  \nElham Jalili TazekandeJanze1, SholehAlaei1􀀍 & Bahar Meshginqalam2  \nIn this study, we have unveiled an SPR biosensor for highly sensitive and rapid detection of cancerous cells employing 2D materials. The proposed sensor structure introduces a novel approach to cancer cell detection, offering a new perspective in biosensing technology. In other words, specifically, ZnO, Si3N4 and TMDCs based plasmonic sensor structures demonstrate great potential whenever high-accuracy detection of cancerous cells is required. We present four different configuration ofSPR based sensor designed for the detection of different types of cancer cells. The designed conventional configuration consists of four functional layers namely Ag, ZnO, Si3N4 and sensing medium along with BK7 prism for coupling light at the interface of metal-dielectric. To illustrate performance improvement, enhancement of light absorption capacity and achieve higher sensitivity of sensor, we incorporated four different 2D materials, MoS2, MoSe2, WS2 and WSe2. Using the angular interrogation method, the proposed layered structure, BK7/ZnO/Ag/Si3N4/WS2/sensing medium, demonstrated the highest overall sensitivity in terms of detecting three cancerous cells, blood cancer (Jurkat), cervical cancer (HeLa) and skin cancer (Basal) from healthy cells. Notably, the sensitivity which is achieved with the configuration BK7/ZnO/Ag/Si3N4/WS2/sensing medium for blood cancer detection from healthy cells with the value of 342.14 deg/RIU and FOM equal to 124.86 RIU−1, outperforms all other proposed configurations. Applying finite element method (FEM) simulations, the distribution of electric field across the interfaces ofthe SPR sensor configurations are analyzed. Overall, SPR biosensors offera promising technology for the early and accurate cancerous cell detection. The high sensitivity, specificity, and ability to analyze complex biological samples make them valuable tools in the struggle against cancer. However, further research and development are demanded to optimize the performance and translation of these sensors into clinical and real-world applications.  \nKeywords SPR, Biosensor, Cancer detection, TMDCs, ZnO, Sensitivity  \nAccording to the declaration of the World Health Organization, one of the main causes of death around the world is cancer. Significant efforts have been made to develope early, accurate and cost-effective methods and treatments. The various types of cancer can be detected early using different methods and techniques such as peptide-based optical biosensors, electroactive material-based immunosensors, plasmonic fiber optic biosensors, fluorescence spectroscopy, surface plasmon resonance (SPR) biosensor, Colorimetric biosensors and etc1–5. Notwithstanding notable advances in diagnosis of cancer, researchers intend to recognize accurate treatment methods and effective screening with a focus on the identification and application of disease biomarkers6.  \nThe surface plasmon resonance (SPR) is a widely used technique for the on-the-spot detection of biomarkers in cancers since it can evaluate biomarkers with outstanding selectivity, rapid and reproducibility and can identify different types of cancers. Furthermore, SPR biosensors are used for studying molecular binding, molecular interactions and investigating the changes of conformation of biomolecules and ions for application in various fields such as environmental sciences, medicine, engineering and etc. The sensing mechanism of SPR biosensor is based on the change in the refractive index (RI) of the sensing medium for determination of molecule binding at a metal surface. By incorporating various layers and combinations, researchers have tried to improve the sensitivity of the SPR biosensors which paves the way for detecting subt","cbCaimNQHlFTPmo7","https://ap.wps.com/l/cbCaimNQHlFTPmo7","pdf",3079495,17,"English","# Introduction\n## Cancer detection needs and biomarker diagnosis\n## SPR biosensing principles and motivation\n# Sensor Design and Methodology\n## Layered SPR configurations and materials\n## Angular interrogation and performance evaluation\n## FEM simulation of electric-field distribution\n# Results and Discussion\n## Sensitivity comparison across cancer cell types\n## Best configuration for blood cancer detection\n# Conclusion\n## Potential and future translation considerations","[{\"question\":\"What biosensor architecture is proposed for cancer detection?\",\"answer\":\"The study proposes an SPR biosensor using a layered structure with ZnO, Si3N4, Ag, and a sensing medium coupled through a BK7 prism, enhanced with 2D TMDC materials.\"},{\"question\":\"How do the 2D TMDC materials improve sensing performance?\",\"answer\":\"The sensor incorporates MoS2, MoSe2, WS2, and WSe2 to enhance light absorption capacity and increase overall sensitivity toward subtle refractive index changes.\"},{\"question\":\"Which configuration shows the highest sensitivity and what is its performance for blood cancer detection?\",\"answer\":\"The BK7/ZnO/Ag/Si3N4/WS2/sensing medium configuration yields the highest overall sensitivity, with blood cancer detection from healthy cells reaching 342.14 deg/RIU and FOM of 124.86 RIU−1.\"}]","On the sensing performance improvement in SPR biosensor using ZnO and TMDCs architecture for cancer detection | PDF",1790165102,43,[148,152,156,160],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/f005189b90b43a6f546c9b9077c596a3.webp",983,1291,{"page_no":14,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/6047f36dfbe9e27e793273cc6efed699.webp",982,1290,{"page_no":81,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/64d0ce28e84beaabc9423599a715ae3e.webp",981,1289,{"page_no":19,"url":161,"width":162,"height":163},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/28d42a3794bb9a65c363ef702d3e303f.webp",980,1287]