[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-641867-105":59,"doc-detail-641867-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","omron-m2-automatic-blood-pressure-monitor-instruction-manual","OMRON M2 Automatic Blood Pressure Monitor - Instruction Manual","","OMRON M2 Automatic Blood Pressure Monitor instruction manual provides purpose-driven guidance for measuring blood pressure and pulse rate in adults. It explains automatic operation on the oscillometric principle, including irregular heartbeat detection and warnings. The document covers critical safety information for general use and optional AC adapter and battery handling, highlighting contraindications and precautions for pregnancy, arrhythmia, and improper environments. It also details device components and key parts for setup and use.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/omron-m2-automatic-blood-pressure-monitor-instruction-manual/641867/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/omron-m2-automatic-blood-pressure-monitor-instruction-manual/641867.png","ImageObject",300,407,{"name":92,"@type":93},"dbqoiu","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-07","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":29},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the intended use of the OMRON M2 blood pressure monitor?","Question",{"text":112,"@type":113},"It is a digital monitor intended for measuring blood pressure and pulse rate in adults who can understand the instruction manual and use the correct arm cuff arm circumference range. It warns when irregular heartbeats appear during measurement.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Who should consult a physician before using the device?",{"text":117,"@type":113},"Consult a physician before use in pregnancy (including pre-eclampsia) and if diagnosed with arrhythmia or arteriosclerosis. Also consult a physician for use with an arterio-venous (A-V) shunt, after mastectomy, or for people with severe blood flow problems or blood disorders.",{"name":119,"@type":110,"acceptedAnswer":120},"What safety precautions should be followed during measurement and device placement?",{"text":121,"@type":113},"Do not use on an injured arm or in areas with HF surgical equipment, MRI, or CT scanners, or in oxygen-rich environments. Avoid using the device in a moving vehicle and do not take measurements more than necessary; remove the arm cuff if abnormalities occur.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},641867,1792947702,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":29,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":14,"language":139,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":67,"update_tm":143,"read_time":24,"preview_page_count":4},3985747862462,"https://ap-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","Automatic Blood Pressure Monitor  \nModel M2  \nInstruction Manual  \nIM-HEM-7121-E-EN-01-08/2013 2298866-7A  \nIntroduction  \nThank you for purchasing the OMRON M2 Automatic Blood Pressure Monitor. The OMRON M2 is a compact, fully automatic blood pressure monitor, operating on the oscillometric principle. It measures your blood pressure and pulse rate simply and quickly. For comfortable controlled inflation without the need of pressure pre-setting or re-inflation the device uses its advanced “IntelliSense” technology.  \nIntended Use  \nThis device is a digital monitor intended for use in measuring blood pressure and pulse rate in adult patient population who can understand this instruction manual with the arm circumference range printed on the arm cuff. The device detects the appearance of irregular heartbeats during measurement and gives a warning signal with the measurement result.  \n Please read this instruction manual thoroughly before using the device.  \nPlease keep for future reference. For specific information about your own blood pressure, CONSULT YOUR PHYSICIAN.  \nImportant Safety Information  \n Warning: Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.  \n(General Usage)  \nConsult your physician before using the device in pregnancy including pre-eclampsia, or if diagnosed with arrhythmia or arteriosclerosis.  \nDo not use the device on the injured arm or the arm under medical treatment.  \nDo not apply the arm cuff on the arm while being on an intravenous drip or blood transfusion.  \nConsult your physician before using the device on the arm with an arterio-venous (A-V) shunt.  \nDo not use the device with other medical electrical (ME) equipment simultaneously.  \nDo not use the device in the area the HF surgical equipment, MRI, or CT scanner exists, or in the oxygen rich environment.  \nThe air tube or the AC adapter cable may cause accidental strangulation in infants.  \nContained small parts that may cause a choking hazard if swallowed by infants.  \n(AC Adapter (optional) Usage)  \nDo not use the AC adapter if the device or the power cord is damaged. Turn off the power and unplug the power cord immediately.  \nPlug the AC adapter into the appropriate voltage outlet. Do not use in a multi-outlet plug.  \nNever plug in or unplug the power cord from the electric outlet with wet hands.  \n Caution: Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury to the user or patient or damage to the equipment or other property.  \n(General Usage)  \nAlways consult your physician. Self-diagnosis of measurement results and self-treatment are dangerous.  \nPeople with severe blood flow problems, or blood disorders, should consult a physician before using the device, as the arm cuff inflation can cause bruising.  \nIf there are any abnormalities during the measurement, remove the arm cuff.  \nDo not use this device on infants or persons who cannot express their intentions.  \nDo not inflate the arm cuff more than necessary.  \nDo not use the device for any purpose other than measuring blood pressure.  \nUse only the approved arm cuff for this device. Use of other arm cuffs may result in incorrect measurement results.  \nDo not use a mobile phone or other devices that emit electromagnetic fields, near the device. This may result in incorrect operation of the device.  \n Do not disassemble the monitor or arm cuff.  \nDo not use in a location with moisture, or a location where water may splash on the device. This may damage the device.  \nDo not use the device in a moving vehicle (car, airplane) .  \nDo not take measurements more than necessary. It may cause bruising due to blood flow interference.  \nConsult your physician before using the device if you had a mastectomy.  \n(AC Adapter (optional) Usage)  \n Fully insert the power plug into the outlet.  \nWhen disconnecting the power plug from the outlet, do not pull the power cord. Be sure to pull from the ","cbCain1RukM6lgi8","https://ap.wps.com/l/cbCain1RukM6lgi8","pdf",303331,"English","# Introduction\n## Intended Use\n## Important Safety Information\n# Know Your Device\n## Contents\n## Monitor\n## Arm Cuff\n## Display","[{\"question\":\"What is the intended use of the OMRON M2 blood pressure monitor?\",\"answer\":\"It is a digital monitor intended for measuring blood pressure and pulse rate in adults who can understand the instruction manual and use the correct arm cuff arm circumference range. It warns when irregular heartbeats appear during measurement.\"},{\"question\":\"Who should consult a physician before using the device?\",\"answer\":\"Consult a physician before use in pregnancy (including pre-eclampsia) and if diagnosed with arrhythmia or arteriosclerosis. Also consult a physician for use with an arterio-venous (A-V) shunt, after mastectomy, or for people with severe blood flow problems or blood disorders.\"},{\"question\":\"What safety precautions should be followed during measurement and device placement?\",\"answer\":\"Do not use on an injured arm or in areas with HF surgical equipment, MRI, or CT scanners, or in oxygen-rich environments. Avoid using the device in a moving vehicle and do not take measurements more than necessary; remove the arm cuff if abnormalities occur.\"}]","OMRON M2 Automatic Blood Pressure Monitor - Instruction Manual | PDF",1792718538]