[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-646497-105":59,"doc-detail-646497-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","omega-user-manual-product-notice-document-ref-d1201-09","OMEGA - User Manual - Product notice - Document Ref. D1201-09","","User manual for the OMEGA family load limiter and rope tension measurement devices, detailing product description, model-dependent functions, and supported sensor capacity up to 16 sensors. Specifies electrical and installation parameters such as power supply range, relay outputs, analog output formats (0-10V/4-20mA/0-20mA and 0-5V where applicable), and CANopen/CAN connectivity. Includes documentation references, firmware version information, menu navigation, settings submenus (information, calibration, alarms, chain compensation, CanOpen, ADC, analog outputs, cabin display), NG technology features, firmware updates, and an errors section with error codes.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/omega-user-manual-product-notice-document-ref-d1201-09/646497/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/omega-user-manual-product-notice-document-ref-d1201-09/646497.png","ImageObject",300,407,{"name":92,"@type":93},"Grenda","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-28","2026-10-23",true,{"@type":102,"interactionType":103,"userInteractionCount":81},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What is the OMEGA device used for?","Question",{"text":112,"@type":113},"The OMEGA is a load limiter and rope tension measurement device that provides tension readings and supports alarm signaling and controller connectivity depending on the model.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"Which outputs and communication interfaces are supported by different OMEGA models?",{"text":117,"@type":113},"Models may support relay alarms, analog outputs (0-10V and/or 4-20mA/0-20mA, and in some cases 0-5V), CAN/CANopen connectivity, and a cabin display MB output, as listed in the model comparison table.",{"name":119,"@type":110,"acceptedAnswer":120},"How do you enter the settings menu on the device?",{"text":121,"@type":113},"Keep the button M pressed to enter or exit the settings menu. The menu follows a cyclic structure of multiple submenus.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},646497,1793111377,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":81,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":36},7971474921005,"https://ap-avatar.wpscdn.com/davatar_29158cc5080c5b710cf443261637dec0","(EN)  \nOMEGA  \nUser Manual  \nOMEGA6-4RMA  \nOMEGA6-4R5V  \nOMEGA6-C  \nOMEGA6-Ca  \nOMEGA12-4RMA  \nOMEGA12-4R5V  \nOMEGA12-C  \nOMEGA12-Ca  \nOMEGA16-4RMA  \nOMEGA16-C  \nOMEGA16-Ca  \nDinacell Electrónica S. L.  \nDinacell Electronica S. L.  \nThe contained information in this document is subject to changes without previous notice. The content shown here should be used as general product information. It should not be interpreted as a guarantee of quality or durability. Electronic Dinacell shall not be liable for technical or editing errors or omissions contained in this document.  \nDocument Ref.: D1201-09  \nPublication date: 24/10/2022  \nFirmware version: 1.05  \nProduct notice  \nThis manual describes the characteristic of the products in its most updated version.  \nThe resources and functions includedin this manual applies to the OMEGA family of models (not all models incorporate all functions).  \nNot all resources are available in all editions or versions of the OMEGA.  \nFor more information  \n[www.](www.dinacell.com)[dina](www.dinacell.com)[cell.com](www.dinacell.com)  \nINDEX  \n1 Introduction   2  \n1.1 Product description   2  \n1.2 Features by model   2  \n1.3 Electrical speciﬁcations   2  \n2 Technical data for installation   3  \n2.1 Dimensions (mm) and connections   3  \n3 Internal structure & device management   4  \n3.1 Menu Structure   4  \n3.2 Button functions   4  \n4 Settings Menu   5  \n4.1 Settings Menu   5  \n4.2 Information submenu   6  \n4.3 Calibration submenu   6  \n4.4 Alarm submenu   7  \n4.5 Chain compensation submenu   8  \n4.6 CanOpen submenu   9  \n4.7 ADC submenu   9  \n4.8 Analog output submenu   10  \n4.9 Cabin display submenu   10  \n5 NG technology   11  \n5.1 Conﬁguration from smartphone, tablet or laptop   11  \n5.2 Function for adjusting the rope/belt tension   11  \n5.3 Firmware update   11  \n6 Errors   12  \n6.1 Error Codes   12  \n7 Quick guide for OMEGA installation   13  \n7.1 Device Installation   13  \n7.2 Set up   13  \n7.3 Device conﬁguration   13  \nIntroduction 1  \n1.1 Product description  \nThe OMEGA is a load limiter and rope tension measurement device.  \nDepending on the model, it supports one individual reading of up to 16 sensors. The device can be connected to any controller via relay alarms or analog outputs as well as Can Bus.  \n1.2 Features by model  \nIn this manual you will ﬁnd the resources and functions that include the OMEGA family model set (not all models incorporate all the functions) .  \nCheck or verify the functions included in your model, with the table below.  \n\n| Models |  | OMEGA6-4RMA | OMEGA6-4R5V | OMEGA6-C |  | OMEGA6-Ca | OMEGA 12-4RMA | OMEGA 12-4R5V | OMEGA 12-C | OMEGA 12-Ca | OMEGA 16-4RMA | OMEGA 16-C | OMEGA 16-Ca |\n| --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- | --- |\n| Input channel | - | 6 |  |  |  |  | 12 |  |  |  | 16 |  |  |\n| Temperature range\u003Cbr>Working  Storage | °C (°F) | -10 ... +65 (+14 ... +149) |  |  |  |  |  |  |  |  |  |  |  |\n|  |  | -20 ... +70 (-4 ... +158) |  |  |  |  |  |  |  |  |  |  |  |\n| Relay | - | 4 |  |  | - |  | 4 |  | - |  | 4 | - |  |\n| Alarms | - | 5 |  |  |  |  |  |  |  |  |  |  |  |\n| Analog outputs 0-10V / 4-20mA / 0-20mA | - | ✓ | - | - |  | ✓ | ✓ | - | - | ✓ | ✓ | - | ✓ |\n| Analog outputs 0-5V |  | - | ✓ | - |  | - | - | ✓ | - | - | - | - | - |\n| CANopen-Lift CIA 417 (Isolated) | - | - | - | ✓ |  | ✓ | - | - | ✓ | ✓ | - | ✓ | ✓ |\n| Cabin display MB output | - | ✓ | - | - |  | - | ✓ | - | - | - | ✓ | - | - |\n| NG technology (with USB for firmware upgrade) | - | ✓ |  |  |  |  |  |  |  |  |  |  |  |\n\n1.3 Electrical speciﬁcations  \n\n| Parameter |  | Units | Specifications |\n| --- | --- | --- | --- |\n| Power supply (Short circuit protected. It is not necessary to replace any fuse) |  | VDC | 10   40 |\n| Maximum current consumption |  | mA | \u003C 200 |\n| Relay contact | Max. voltage\u003Cbr>Max. current Type | VAC | 250 |\n|  |  | A | 3 |\n|  |  | - | NO |\n| Hold Input |  | VAC/DC | 12   125 |\n| Casing material |  | - | IP50 Fireproof pl","cbCaic6S7mxP0K7w","https://ap.wps.com/l/cbCaic6S7mxP0K7w","pdf",850297,16,"English","# 1 Introduction\n## 1.1 Product description\n## 1.2 Features by model\n## 1.3 Electrical specifications\n# 2 Technical data for installation\n## 2.1 Dimensions (mm) and connections\n# 3 Internal structure & device management\n## 3.1 Menu Structure\n## 3.2 Button functions\n# 4 Settings Menu\n## 4.1 Settings Menu\n## 4.2 Information submenu\n## 4.3 Calibration submenu\n## 4.4 Alarm submenu\n## 4.5 Chain compensation submenu\n## 4.6 CanOpen submenu\n## 4.7 ADC submenu\n## 4.8 Analog output submenu\n## 4.9 Cabin display submenu\n# 5 NG technology\n## 5.1 Configuration from smartphone, tablet or laptop\n## 5.2 Function for adjusting the rope/belt tension\n## 5.3 Firmware update\n# 6 Errors\n## 6.1 Error Codes\n# 7 Quick guide for OMEGA installation\n## 7.1 Device Installation\n## 7.2 Set up\n## 7.3 Device conﬁguration","[{\"question\":\"What is the OMEGA device used for?\",\"answer\":\"The OMEGA is a load limiter and rope tension measurement device that provides tension readings and supports alarm signaling and controller connectivity depending on the model.\"},{\"question\":\"Which outputs and communication interfaces are supported by different OMEGA models?\",\"answer\":\"Models may support relay alarms, analog outputs (0-10V and/or 4-20mA/0-20mA, and in some cases 0-5V), CAN/CANopen connectivity, and a cabin display MB output, as listed in the model comparison table.\"},{\"question\":\"How do you enter the settings menu on the device?\",\"answer\":\"Keep the button M pressed to enter or exit the settings menu. The menu follows a cyclic structure of multiple submenus.\"}]","OMEGA - User Manual - Product notice - Document Ref. D1201-09 | PDF",1792762981]