[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-403525-105":59,"doc-detail-403525-en":131},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":124,"head_meta":126,"extra_data":128,"updated_unix":130},105,"en","olympia-n70-1-nitrogen-generator-user-manual-installation-use-and-maintenance","OLYMPIA N70-1 Nitrogen Generator - User Manual - Installation, Use and Maintenance","","Comprehensive user guidance for CLAIND OLYMPIA N70-1 nitrogen generators, covering installation, operation, and routine maintenance. The manual details required safety practices, including heat and weather precautions, protective casing use, and restrictions on repairs to qualified personnel. It explains safety devices for maximum pressure and temperature control, provides equipment contents and technical specifications (dimensions, gas delivery, connections and power requirements), and outlines escalation to CLAIND technical assistance when faults cannot be resolved.",{"@graph":69,"@context":123},[70,84,106],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":35,"@type":76,"position":81},"https://docshare.wps.com/document/healthcare/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/olympia-n70-1-nitrogen-generator-user-manual-installation-use-and-maintenance/403525/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/olympia-n70-1-nitrogen-generator-user-manual-installation-use-and-maintenance/403525.png","ImageObject",300,407,{"name":92,"@type":93},"dhado","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-29","2026-09-27",true,{"@type":102,"interactionType":103,"userInteractionCount":105},"InteractionCounter",{"@type":104},"ViewAction",12,{"@type":107,"mainEntity":108},"FAQPage",[109,115,119],{"name":110,"@type":111,"acceptedAnswer":112},"What safety rules must be followed when installing and using the generator?","Question",{"text":113,"@type":114},"Install and operate the unit according to this booklet. Ensure it is used only as described in the manual to keep the warranty valid and avoid CLAIND liability.","Answer",{"name":116,"@type":111,"acceptedAnswer":117},"What happens if the generator’s pressure or temperature exceeds safe limits?",{"text":118,"@type":114},"Maximum pressure is continuously monitored; if malfunction occurs, a safety valve prevents pressure from exceeding 10.5 bar. A temperature safety device shuts off power to the compressor if overheating occurs beyond the maximum operating temperature.",{"name":120,"@type":111,"acceptedAnswer":121},"What should the user do when a fault cannot be resolved using the Troubleshooting chapter?",{"text":122,"@type":114},"Contact CLAIND Technical Assistance. Repairs and inspections must be carried out exclusively by qualified personnel.","https://schema.org",{"og:url":83,"og:type":125,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":127,"canonical":83},"index,follow",{"doc_id":129,"site_id":62},403525,1790618767,{"code":4,"msg":5,"data":132},{"doc_id":129,"user_id":133,"nickname":92,"user_avatar":134,"doc_module":4,"category_id":34,"category_name":35,"doc_title":65,"doc_description":67,"doc_content":135,"file_id":136,"file_url":137,"file_type":138,"file_size":139,"view_count":105,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":140,"language":141,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":142,"faqs":143,"seo_title":144,"seo_description":67,"update_tm":145,"read_time":146,"preview_page_count":4},5909893218464,"https://ap-avatar.wpscdn.com/davatar_085a072bc5b1113ac321206ff7593b45","User Manual  \nNitrogen Generator  \nOLYMPIA N70-1  \n1  \nTable of Contents  \n1. Introduction ......................................................................................................... 3  \n2. Safety ................................................................................................................... 4  \n3. Generator description .......................................................................................... 5  \n4. Installation ......................................................................................................... 10  \n5. Uninstalling and Transport ................................................................................. 15  \n6. Use ..................................................................................................................... 16  \n7. Maintenance ...................................................................................................... 26  \n8. Troubleshooting................................................................................................. 33  \n9. Warranty............................................................................................................ 38  \n10. Declaration of conformity .................................................................................. 39  \n11. Maintenance book ............................................................................................. 40  \n12. MODBUS ............................................................................................................ 41  \n13. Notes ................................................................................................................. 43  \n2  \n1. Introduction  \nThis document is intended for users of CLAIND OLYMPIA nitrogen generators and provides all information regarding installation use and maintenance.  \n􀁸 OLYMPIA N70-1 230V ~ 50Hz, part number 400.30.0010.00  \nOLYMPIA N70-1 generator is designed to provide nitrogen for laboratory instruments (including gas chromatographs, atomic absorption instrumentation, etc. ) .  \nAs regards the installation operations, the generator is configured in such a way that it can be installed by the user.  \nAs regards general maintenance operations, the generator is configured in such a way that it can be maintained, limited to the most frequent operations, by the user.  \nAs regards specific maintenance operations not provided for be carried on by the user, the intervention of a specialized technician is required.  \nThe margin of the text contains the following symbols indicating:  \n compulsory safety standards to be observed  \n Electrical hazard  \n Recommendations and important information  \nIt is strongly recommended to carefully read all safety warnings (para. 2.1.) before carrying out any operation on the generator.  \n3  \n2. Safety  \nThe unit must be installed and used in observance of the instructions in this booklet. Furthermore, use of the generator must be limited to that described in Chapter 1 Introduction. Failure to observe the foregoing will render the guarantee null and void and release CLAIND from all liability for direct or indirect damage or physical injury. The user is responsible for asking local authorities if there are local safety regulations that are stricter than what is described in this manual  \n2.1. Warnings  \nPlace the generator FAR FROM SOURCES OF HEAT  \nPlace the generator in an environment PROTECTED AGAINST RAIN AND WIND The generator’s protective casing must always be in place when it is running: risk of burns due to contact with hot parts  \nNever remove its protective casing if the generator is connected to its power supply: risk of death by electrocution  \nIn the event of faults which cannot be resolved according to the procedures in the TROUBLESHOOTING chapter, contact CLAIND Technical Assistance. Repairs and inspections must be carried out exclusively by QUALIFIED PERSONNEL  \n2.2. Safety devices  \nMAXIMUM PRESSURE: pressure is monitored cont","cbCainCFi5MDmQOq","https://ap.wps.com/l/cbCainCFi5MDmQOq","pdf",1938077,44,"English","# Introduction\n# Safety\n## Warnings\n## Safety devices\n## Technical Assistance\n# Generator description\n## Equipment supplied\n## Technical specifications\n# Installation\n# Use\n# Maintenance\n# Troubleshooting\n# Warranty\n# Declaration of conformity\n# Maintenance book\n# MODBUS\n# Notes","[{\"question\":\"What safety rules must be followed when installing and using the generator?\",\"answer\":\"Install and operate the unit according to this booklet. Ensure it is used only as described in the manual to keep the warranty valid and avoid CLAIND liability.\"},{\"question\":\"What happens if the generator’s pressure or temperature exceeds safe limits?\",\"answer\":\"Maximum pressure is continuously monitored; if malfunction occurs, a safety valve prevents pressure from exceeding 10.5 bar. A temperature safety device shuts off power to the compressor if overheating occurs beyond the maximum operating temperature.\"},{\"question\":\"What should the user do when a fault cannot be resolved using the Troubleshooting chapter?\",\"answer\":\"Contact CLAIND Technical Assistance. Repairs and inspections must be carried out exclusively by qualified personnel.\"}]","OLYMPIA N70-1 Nitrogen Generator - User Manual - Installation, Use and Maintenance | PDF",1790541200,111]