[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-639714-105":59,"doc-detail-639714-en":133},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":126,"head_meta":128,"extra_data":130,"updated_unix":132},105,"en","oem-6m-rf-plasma-generator-service-manual-revision-control-form","OEM-6M - RF Plasma Generator - Service Manual - Revision Control Form","","Service manual for the OEM-6M RF Plasma Generator, focusing on safe handling of high RF output voltages and environmental maintenance requirements. Includes notices on CFC restrictions and implications for no-clean flux residue, plus production and quality system statements. Provides warranty terms, service and technical assistance procedures, RMA authorization workflow, and guidance on the information needed for prompt support. Contains a revision control form with part numbers and revision level details.",{"@graph":69,"@context":125},[70,84,104],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/oem-6m-rf-plasma-generator-service-manual-revision-control-form/639714/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":98,"encodingFormat":97,"isAccessibleForFree":99,"interactionStatistic":100},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/oem-6m-rf-plasma-generator-service-manual-revision-control-form/639714.png","ImageObject",300,407,{"name":92,"@type":93},"Cipher","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-22",true,{"@type":101,"interactionType":102,"userInteractionCount":4},"InteractionCounter",{"@type":103},"ViewAction",{"@type":105,"mainEntity":106},"FAQPage",[107,113,117,121],{"name":108,"@type":109,"acceptedAnswer":110},"Why is extreme caution required when handling the OEM-6M RF Plasma Generator?","Question",{"text":111,"@type":112},"High RF voltages may be present at the output of the unit. Operating personnel must use extreme caution and be thoroughly familiar with the manual’s guidance.","Answer",{"name":114,"@type":109,"acceptedAnswer":115},"What does the manual specify about CFC solvents during maintenance?",{"text":116,"@type":112},"Do not use any CFC (chlorofluorocarbon) solvent in maintenance. The product is manufactured without CFCs, and no-clean flux residue must not be disturbed with CFC cleaning.",{"name":118,"@type":109,"acceptedAnswer":119},"What information is needed to request service or repairs, and how is authorization handled?",{"text":120,"@type":112},"Provide model and serial number, purchase order number, detailed malfunction description, and company Bill To/Ship To addresses. The customer service department issues an RMA number; include it on the purchase order and shipping label before returning the unit.",{"name":122,"@type":109,"acceptedAnswer":123},"How is the warranty service process described in the manual?",{"text":124,"@type":112},"For one year from delivery, the unit is warranted against defects in materials and workmanship. Warranty service requires returning the instrument with transportation prepaid to the factory or designated service centers, and repairs may be billed if damage results from specified causes.","https://schema.org",{"og:url":83,"og:type":127,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":129,"canonical":83},"index,follow",{"doc_id":131,"site_id":62},639714,1792704972,{"code":4,"msg":5,"data":134},{"doc_id":131,"user_id":135,"nickname":92,"user_avatar":136,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":137,"file_id":138,"file_url":139,"file_type":140,"file_size":141,"view_count":4,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":142,"language":143,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":144,"faqs":145,"seo_title":146,"seo_description":67,"update_tm":132,"read_time":147},687208528416,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","⑧  \n# SERVICE MANUAL\n\nOEM-6M  \nRF Plasma Generator  \nHIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THISUNIT.All operating personnel should use extreme caution in handling thesevoltages and be thoroughly familiar with this manual.  \nDO NOT USE ANY CFC(CHLOROFLUOROCARBON)SOLVENT IN THEMAINTENANCE OF THIS PRODUCT.In recognition of our responsibility to protectthe environment,this product has been manufactured without the use of CFC's.Theno-clean flux now used in all soldering operations may leave a smallinert residuewhich will not affect the performance of the product.The use of CFC's for cleaning ormaintenance may result in partial liquification of the no-clean flux residue,which willdamage the unit and void the warranty.  \nThis product is manufactured at ENI's Rochester NY plant,an ISO 9001 QualitySystem Certified Facility.  \n# Notice\n\nThe material contained in this manual is subject to change without notice.No part of this manual may bereproduced or utilized in any form or by any means,electronic or mechanical,including photocopying orelectronic transmission or other means of reproduction or distribution without prior written consent of ENI.The drawings,specifications and other technical information contained in this manual are the property ofENI and shall not be copied,reproduced or used in any way,in whole or in part,as the basis ofmanufacture or sale of similar items without the prior written consent of ENI.  \n        Warranty           \nENI warrants to the original purchaser for a period of one year from the date of delivery,eachinstrument to be free from defects in materials and workmanship.For a period of one year,ENI will,at its option,adjust,repair,or replace defective parts,without charge to the original purchaser,sothat the instrument performs according to its specifications.  \nWhen warranty service is required,the instrument must be returned,transportation prepaid,tothe factory or to one of ENI's designated service centers.If,in our opinion,the instrument has beendamaged by accident,unreasonable use,buyer-supplied software or interfacing,improper sitepreparation or maintenance,or abnormal conditions of operation,repairs will be billed at standardrates.In this case,an estimate will be submitted before the work is started.  \nTHIS LIMITED WARRANTY IS EXCLUSIVE AND ENI MAKES NO OTHER WARRANTIES,EXPRESS OR IMPLIED,AND ALL OTHER EXPRESS ORAL OR WRITTEN WARRANTIES ANDALL WARBANTIES IMPLIED BY LAWW.INCLUDING ANY WARRANTIES OF MERCHANTABILITYOR FITNESS FOR A PARTICULAR PURPOSE OR OTHER WARRANTY OF QUALITY AREEXCLUDED AND DISCLAIMED.IN NO EVENT SHALL ENI BE LIABLE FOR SPECIAL.INDIRECT.INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM BREACH OF ANYWARRANTY,WHETHER EXPRESS OR IMPLIED,INCLUDING ANY IMPLIED WARRANTY OFMERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE,OR FROM ANY CAUSEWHATSOEVER,INCLUDING NEGLIGENCE.Buyer's sole and exclusive remedy under thiswarranty shall be repair or replacement as set forth above,or if ENI is unable to repair or replace thedefective part within a reasonable time,a refund of the price of the part or goods which give rise tothe warranty claim.  \n# Service And Technical Assistance\n\nFor Service or Repair contact the closest Customer Service Department with the followinginformation:  \n·Model and serial number  \n● Purchase order number  \n·Detailed description of malfunction  \n·Your company's \"Bill To\"and \"Ship To\"address  \nYou will receive a RMA(Return Materials Authorization)number,the warranty status of the unit to bereturned and estimated repair charge,if any.The RMA number is your authorization number.Please type this number on your purchase order and shipping label.After ENI receives the unit,afirm quote and estimated date of completion will be given.  \nFor Technical Assistance for your particular application,contact the nearest ENI Sales and ServiceCenter.The following information will help us provide you with prompt and efficient service:  \n·Allof the information contained on the unit's","cbCaiteekKfT7gfR","https://ap.wps.com/l/cbCaiteekKfT7gfR","pdf",2341407,36,"English","# Service Manual\n## Notice\n## Warranty\n## Service And Technical Assistance\n## Product Manual Revision Control Form","[{\"question\":\"Why is extreme caution required when handling the OEM-6M RF Plasma Generator?\",\"answer\":\"High RF voltages may be present at the output of the unit. Operating personnel must use extreme caution and be thoroughly familiar with the manual’s guidance.\"},{\"question\":\"What does the manual specify about CFC solvents during maintenance?\",\"answer\":\"Do not use any CFC (chlorofluorocarbon) solvent in maintenance. The product is manufactured without CFCs, and no-clean flux residue must not be disturbed with CFC cleaning.\"},{\"question\":\"What information is needed to request service or repairs, and how is authorization handled?\",\"answer\":\"Provide model and serial number, purchase order number, detailed malfunction description, and company Bill To/Ship To addresses. The customer service department issues an RMA number; include it on the purchase order and shipping label before returning the unit.\"},{\"question\":\"How is the warranty service process described in the manual?\",\"answer\":\"For one year from delivery, the unit is warranted against defects in materials and workmanship. Warranty service requires returning the instrument with transportation prepaid to the factory or designated service centers, and repairs may be billed if damage results from specified causes.\"}]","OEM-6M - RF Plasma Generator - Service Manual - Revision Control Form | PDF",91]