[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-677191-105":3,"detail-sidebar-cat-0-en-105":79,"doc-detail-677191-en":129},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":72,"head_meta":74,"extra_data":76,"updated_unix":78},105,"en","odeon-in-wall-tank-installation-instructions-k-6283kk-6284kk-6286kk-6286r","ODEON In-wall Tank - Installation Instructions - K-6283K/K-6284K/K-6286K/K-6286R","","Installation instructions for the ODEON in-wall tank models K-6283K, K-6284K, K-6286K, and K-6286R. Provides safety and handling guidance, including careful installation to prevent product damage, avoiding erosive cleansers and unapproved parts, and following the documented procedures. Explains tank functions such as anti flow-backwards, gear flushing (single/double), adjustable inlet water level and flushing volume, and adjustable toilet height. Includes installation concepts, roughing-in dimensions, and step-by-step procedures with the iron rack and without it.",{"@graph":14,"@context":71},[15,34,54],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/technology/","Technology",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/odeon-in-wall-tank-installation-instructions-k-6283kk-6284kk-6286kk-6286r/677191/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":48,"encodingFormat":47,"isAccessibleForFree":49,"interactionStatistic":50},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/odeon-in-wall-tank-installation-instructions-k-6283kk-6284kk-6286kk-6286r/677191.png","ImageObject",300,407,{"name":42,"@type":43},"Blitz","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-04",true,{"@type":51,"interactionType":52,"userInteractionCount":22},"InteractionCounter",{"@type":53},"ViewAction",{"@type":55,"mainEntity":56},"FAQPage",[57,63,67],{"name":58,"@type":59,"acceptedAnswer":60},"What precautions should be followed during installation of the ODEON in-wall tank?","Question",{"text":61,"@type":62},"Read the installation guide carefully and install according to the instructions to avoid product damage and installation inconvenience caused by inappropriate operation. Avoid using erosive cleansers or solvents on the tank.","Answer",{"name":64,"@type":59,"acceptedAnswer":65},"Which parts should not be used or applied during installation?",{"text":66,"@type":62},"Do not apply spares not provided by Kohler. Do not use glass adhesive tape for installing Kohler spares, and ensure only approved components are used to prevent damage not covered by Kohler.",{"name":68,"@type":59,"acceptedAnswer":69},"What are the main differences between installation with an iron rack and without it?",{"text":70,"@type":62},"The document provides separate installation procedures and roughing-in dimension guidance for K-6284K (with iron rack) and K-6286K/K-6286R (without iron rack). Each route specifies its own tank mounting and preparation steps.","https://schema.org",{"og:url":32,"og:type":73,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":75,"canonical":32},"index,follow",{"doc_id":77,"site_id":7},677191,1793777813,{"code":4,"msg":80,"data":81},"success",[82,86,90,94,99,103,108,113,118,121,125],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":83,"show_sort_weight":84,"slug":85},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":87,"show_sort_weight":88,"slug":89},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":91,"show_sort_weight":92,"slug":93},"Exam",70,"exam",{"id":95,"doc_module":4,"doc_module_name":25,"category_name":96,"show_sort_weight":97,"slug":98},5,"Comic",60,"comic",{"id":100,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":101,"slug":102},6,50,"technology",{"id":104,"doc_module":4,"doc_module_name":25,"category_name":105,"show_sort_weight":106,"slug":107},7,"Healthcare",40,"healthcare",{"id":109,"doc_module":4,"doc_module_name":25,"category_name":110,"show_sort_weight":111,"slug":112},8,"Research & Report",30,"research-report",{"id":114,"doc_module":4,"doc_module_name":25,"category_name":115,"show_sort_weight":116,"slug":117},9,"Religion & Spirituality",20,"religion-spirituality",{"id":116,"doc_module":4,"doc_module_name":25,"category_name":119,"show_sort_weight":116,"slug":120},"World Cup","world-cup",{"id":122,"doc_module":4,"doc_module_name":25,"category_name":123,"show_sort_weight":122,"slug":124},10,"Lifestyle","lifestyle",{"id":126,"doc_module":4,"doc_module_name":25,"category_name":127,"show_sort_weight":95,"slug":128},19,"General","general",{"code":4,"msg":80,"data":130},{"doc_id":77,"user_id":131,"nickname":42,"user_avatar":132,"doc_module":4,"category_id":100,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":22,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":138,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":78,"read_time":97},24464137899374,"https://us-avatar.wpscdn.com/davatar_3d24733baf745e90a7e4bdd5f77d97b2","INSTALLATION  \nINSTRUCTIONS  \nODEON IN-WALL TANK  \nK-6283K/K-6284K/K-6286K/K-6286R  \n􀀂 Read installation guide in illustration and word file carefully, and install the tank according to instructions in the guide to avoid product damage and installation inconvenience caused by inappropriate operation.  \n􀀂 All data contained is based upon the last product information available at the time of publication. Kohler Co. Reserves the right to implement changes of product characteristics, packaging and availability at any time without further notice.  \n􀀂 Do not apply erosive cleanser and solvent in the  \ntank, which will damage tank spares and result in leakage in the tank. Kohler will not be responsible for any damage related to above mentioned cleanser or solvent.  \n􀀂 Do not apply spares that are not provided by Kohler, and please note that glass adhesive tape shall not be applied to the installation of Kohler spares. Kohler will not be responsible for any damage related to installation with spares not provided by Kohler.  \n\n| Ordering Information\u003Cbr>ODEON Tank Cover...................................... K-6283K-**\u003Cbr>ODEON In-Wall Tank(With Iron Rack For Wall-Hung Toilet) ................................................ K-6284k-NA | ODEON In-Wall Tank (Without Iron Rack For Wall-Hung Toilet).....................................K-6286K-NA/K-6286R-NA |\n| --- | --- |\n| Function Explanation |  |\n| 􀀂 Anti flow-backwards | 􀀂 Single/double gear flushing |\n| 􀀂 Adjustment of inlet water level\u003Cbr>􀀂 Adjustment of flushing volume | 􀀂 Adjustable toilet height |\n| Design And Installation Concept Of In-wall |  |\n| Tank |  |\n| 􀀂 Installation of in-wall tank is much easier and nice- | that the installation will never be limited to certain area, |\n| looking comparative to that of traditional tank. | and can be installed wherever as you wish, which will |\n| Meanwhile, the space layout will be more | make the bathroom layout more reasonable and nice- |\n| reasonable due to the application of in-wall tank | looking, and make good use of every inch of the |\n| pipes and connectors. | bathroom space. |\n| 􀀂 The most remarkable advantage of in-wall tank is |  |\n\nAdvantages Of In-wall Tank  \n􀀂 Anti-strike and erosion proof tank of macromolecule materials, and leak proof.  \n􀀂 Advanced tank spares, adjustable to flushing of 3/6 liters, with single/double gear technology.  \n􀀂 Sustainable to pressure of 400 kgs.  \n􀀂 Impact free to wall structures, and excellent sound insulation effect.  \n􀀂 Easy installation and time efficient.  \n􀀂 No requirements of other installation spares.  \n􀀂 Easy maintenance and no necessity of removing the wall in the process of maintenance.  \n􀀂 Clean, garbage free, and space-saving efficient.  \nCopyright C 2006 Kohler Co.  \n1048671-K01-B -1-  \nROUGHING-IN  \nInstallation dimensions with iron rack K-6284K UNIT: mm  \n100-155  \nInstallation dimensions without iron rack for wall hung K-6286K/K-6286R  \nUNIT: mm  \n1048671-K01-B -2-  \nINSTALLATION  \nWays of Installation  \nK-6286K-NA/K-6286R-NA  \nK-6284K-NA  \n1 In-wall Tank With Iron Rack For 2 In-wall Tank Without Iron Rack  \nWall-Hung Toilet For Wall-Hung Toilet  \n1048671-K01-B -3-  \nInstallation  \nA. Installation Procedures For In-wall Tank With Iron Rack  \n1. Install the fixing cap in the holes of fixing frame, then tighten the hexagonal screws on the fixing frame with medium allen key as shown in illustration A.  \nTighten the bolts with medium allen key as shown in illustration B, and adjust the height of the adjustable bracket according to customer's requirements.  \nFixing Frame  \nFixing Cap  \nHexagonal Screw  \nTank Frame  \nNut  \nAdjustable Bracket  \nMedium Allen Key  \nA  \nB  \nNut  \n2. Drill four holes with diameter of 12mm and depth of 60mm with churn drilling as shown, and fill in the holes with bulge screw and tighten the long screw.  \n1048671-K01-B -4-  \n3. Tighten the hexagonal long screw with medium allen key as shown in illustration A.  \nTighten the screw of adjustable brackets with  \nm","cbCairn6j0Bd8l56","https://ap.wps.com/l/cbCairn6j0Bd8l56","pdf",2043195,24,"English","# Installation Instructions\n## ODEON In-wall Tank Models\n## Function Explanation\n## Design and Installation Concept\n## Advantages of In-wall Tank\n## Roughing-in\n## Ways of Installation\n## Installation Procedures (With Iron Rack)\n## Installation Procedures (Key Steps)","[{\"question\":\"What precautions should be followed during installation of the ODEON in-wall tank?\",\"answer\":\"Read the installation guide carefully and install according to the instructions to avoid product damage and installation inconvenience caused by inappropriate operation. Avoid using erosive cleansers or solvents on the tank.\"},{\"question\":\"Which parts should not be used or applied during installation?\",\"answer\":\"Do not apply spares not provided by Kohler. Do not use glass adhesive tape for installing Kohler spares, and ensure only approved components are used to prevent damage not covered by Kohler.\"},{\"question\":\"What are the main differences between installation with an iron rack and without it?\",\"answer\":\"The document provides separate installation procedures and roughing-in dimension guidance for K-6284K (with iron rack) and K-6286K/K-6286R (without iron rack). Each route specifies its own tank mounting and preparation steps.\"}]","ODEON In-wall Tank - Installation Instructions - K-6283K/K-6284K/K-6286K/K-6286R | PDF"]