[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-663427-105":59,"doc-detail-663427-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","nudura-xr-35-with-dryvit-icf-500-render-system-standard-detail-drawings","Nudura XR-35 with Dryvit ICF 500 Render System - Standard Detail Drawings","","Standard detail drawing set for the Nudura XR-35 form unit combined with the Dryvit ICF 500 render system, including foundation, ground-level transitions, eaves, windows, doors, party walls, intermediate floors/ceilings, internal walls, corners, and render/brick slip transitions. The table lists drawing numbers XRD-01 through XRD-23 with revision status. Guidance includes layered component stack-up notes for membranes, peel-and-stick systems, basecoats, finishes, and drainage measures, and specifies compliance with building regulations. Provider disclaimers limit liability and clarify that information is for guidance only.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":30,"@type":76,"position":81},"https://docshare.wps.com/document/technology/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/nudura-xr-35-with-dryvit-icf-500-render-system-standard-detail-drawings/663427/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/nudura-xr-35-with-dryvit-icf-500-render-system-standard-detail-drawings/663427.png","ImageObject",300,407,{"name":92,"@type":93},"AfterMidnight","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-10-29","2026-10-28",true,{"@type":102,"interactionType":103,"userInteractionCount":19},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"What building system combination do the standard detail drawings cover?","Question",{"text":112,"@type":113},"The drawings cover the Nudura XR-35 form unit with the Dryvit ICF 500 render system, including specified components and transitions across multiple building elements.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"How are the drawings organized in the document?",{"text":117,"@type":113},"A table of contents lists description lines with drawing numbers (XRD-01 to XRD-23) and revision values, covering foundations through windows, walls, corners, and render/brick slip transitions.",{"name":119,"@type":110,"acceptedAnswer":120},"What disclaimer and liability limitations apply to the guidance?",{"text":121,"@type":113},"The document states the recommendations are for information/guidance only and do not constitute professional advice, includes warranty disclaimers, and limits liability for damages arising from use of the guidance.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},663427,1793227700,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":29,"category_name":30,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":19,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":129,"read_time":144},962090896061,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","Standard Detail Drawings  \nNudura XR-35 with Dryvit ICF 500 Render System  \nTremco CPG UK Limited, Coupland Road, Hindley Green, Wigan, WN2 4HT  \nT: 01942 251 400 E: [hello@tremcocpg.](hello@tremcocpg.com)[com](hello@tremcocpg.com)  \nStandard Detail Drawings  \nNudura XR-35 with Dryvit ICF 500 Render System  \nTable of Contents  \n\n| Description | Drawing number | Revision |\n| --- | --- | --- |\n| Foundation detail options – including basements | XRD-01 | 0 |\n| Transition at ground level | XRD-02 | 0 |\n| Foundation & DPC detail | XRD-03 | 0 |\n| Intermediate floor /ceiling with joist hangers | XRD-04 | 0 |\n| Metal deck flooring detail | XRD-05 | 0 |\n| Eaves with sill plate | XRD-06 | 0 |\n| Eaves with anchoring plates | XRD-07 | 0 |\n| Low level roof /porch | XRD-08 | 0 |\n| Window jamb with illbruck i3 system | XRD-09 | 0 |\n| Window jamb with illbruck i3 system & check reveal | XRD-10 | 0 |\n| Window head with illbruck i3 system | XRD-11 | 0 |\n| Window head with illbruck i3 system & check reveal | XRD-12 | 0 |\n| Window sill | XRD-13 | 0 |\n| Door threshold | XRD-14 | 0 |\n| Party wall with ‘T’ straps & vertical fire break | XRD-15 | 0 |\n| Intermediate floor /ceiling with horizontal fire break | XRD-16 | 0 |\n| Internal stud wall | XRD-17 | 0 |\n| Internal block wall | XRD-18 | 0 |\n| Nudura extension on existing property | XRD-19 | 0 |\n| External corner detail | XRD-20 | 0 |\n| Internal corner detail | XRD-21 | 0 |\n| Render /brick slip transition – render above brick slips | XRD-22 | 0 |\n| Render /brick slip transition – render below brick slips | XRD-23 | 0 |\n\nTremco CPG UK Limited, Coupland Road, Hindley Green, Wigan, WN2 4HT  \nT: 01942 251 400 E: [hello@tremcocpg.](hello@tremcocpg.com)[com](hello@tremcocpg.com)  \nStandard Detail Drawings  \nNudura XR-35 with Dryvit ICF 500 Render System  \nThe recommendations relating to this detail drawing provided by Tremco CPG UK Ltd are for information /guidance purposes only and do not constitute professional advice. While we strive to offer accurate and up-to-date information, Tremco CPG UK makes no warranties, expressed or implied, regarding the completeness, accuracy, reliability, or suitability of the guidance  \n/recommendations for any particular purpose.  \nTremco CPG UK Ltd shall not be held liable for any direct, indirect, incidental, special or consequential damages arising out of or in connection with the use of the guidance /recommendations provided.  \nAll systems must comply with National Building Regulations and Standards, it is the responsibility of the Architect, Engineer and Project Designer to evaluate the information and determine its applicability to their specific situation. The Architect, Engineer and Project Designer should seek professional advice tailored to their individual circumstances before making any decisions based on the recommendations.  \nTremco CPG UK Ltd reserves the right to modify or discontinue any recommendations at any time without prior notice.  \nTremco CPG UK Limited, Coupland Road, Hindley Green, Wigan, WN2 4HT  \nT: 01942 251 400 E: [hello@tremcocpg.](hello@tremcocpg.com)[com](hello@tremcocpg.com)  \n| \u003Cbr>Render basecoat and finishes will not sufficiently adhere to membranes or DPCs (including Nudura peel and stick) and is likely to fail if applied over these items. | 1. Nudura form unit ~~ ~~\u003Cbr>2. Dryvit ICF 500 render system~~ ~~(with Fibercoat Base coat)\u003Cbr>3. Bellcast bead with mesh~~ ~~\u003Cbr>4. Dryvit Dryflex base coat with~~  ~~mesh and finish (Weatherlastic\u003Cbr>Smooth preferable in this location) minimum 150 mm above ground.\u003Cbr>5. Render lapped over ME508 ~~  ~~membrane.\u003Cbr>6. illbruck ME508 membrane lapped~~  ~~over peel & stick membrane\u003Cbr>7. Granular fill for drainage\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>\u003Cbr>8. Dimpleboard membrane by others, installed as specified\u003Cbr>9. Nudura waterproof membrane\u003Cbr>| |  |\n| --- | --- | --- | --- |\n|  |  | The recommendations relating to this detail drawing provided by Tremco CPG UK Ltd are for i","cbCaisd8wItzgEH1","https://ap.wps.com/l/cbCaisd8wItzgEH1","pdf",25170823,26,"English","# Table of Contents\n## Foundation detail options – including basements\n## Transition at ground level\n## Foundation & DPC detail\n## Intermediate floor /ceiling with joist hangers\n## Metal deck flooring detail\n## Eaves with sill plate\n## Eaves with anchoring plates\n## Low level roof /porch\n## Window jamb with illbruck i3 system\n## Window head with illbruck i3 system\n## Window sill\n## Door threshold\n## Party wall with ‘T’ straps & vertical fire break\n## Intermediate floor /ceiling with horizontal fire break\n## Internal stud wall\n## Internal block wall\n## Nudura extension on existing property\n## External corner detail\n## Internal corner detail\n## Render /brick slip transition","[{\"question\":\"What building system combination do the standard detail drawings cover?\",\"answer\":\"The drawings cover the Nudura XR-35 form unit with the Dryvit ICF 500 render system, including specified components and transitions across multiple building elements.\"},{\"question\":\"How are the drawings organized in the document?\",\"answer\":\"A table of contents lists description lines with drawing numbers (XRD-01 to XRD-23) and revision values, covering foundations through windows, walls, corners, and render/brick slip transitions.\"},{\"question\":\"What disclaimer and liability limitations apply to the guidance?\",\"answer\":\"The document states the recommendations are for information/guidance only and do not constitute professional advice, includes warranty disclaimers, and limits liability for damages arising from use of the guidance.\"}]","Nudura XR-35 with Dryvit ICF 500 Render System - Standard Detail Drawings | PDF",66]