[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-385672-105":59,"doc-detail-385672-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","novel-self-assembled-multifunctional-nanoprobes-for-second-near-infrared-fluorescence-image-guided-breast-cancer-surgery-and-enhanced-radiotherapy-efficacy","Novel Self-Assembled Multifunctional Nanoprobes for Second-Near-Infrared-Fluorescence-Image-Guided Breast Cancer Surgery and Enhanced Radiotherapy Efficacy","","Breast-conserving surgery is limited by insufficient intraoperative methods to evaluate resection margins, leaving patients at risk of local recurrence when margins are positive. Radiation therapy improves tumor-bed dosing but radiosensitizers fail to meet urgent clinical needs while potentially harming normal tissue. This study designs a self-assembled multifunctional nanoprobe (Gd–diethylenetriaminepentaacetic acid–HSA@indocyanine green–Bevacizumab) for NIR-II fluorescence margin guidance and targeted tumor ROS amplification under X-ray irradiation, enhancing resection precision and radiotherapy efficacy in breast cancer models.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/novel-self-assembled-multifunctional-nanoprobes-for-second-near-infrared-fluorescence-image-guided-breast-cancer-surgery-and-enhanced-radiotherapy-efficacy/385672/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/novel-self-assembled-multifunctional-nanoprobes-for-second-near-infrared-fluorescence-image-guided-breast-cancer-surgery-and-enhanced-radiotherapy-efficacy/385672.png","ImageObject",300,407,{"name":92,"@type":93},"Ivy","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-24","2026-09-24",true,{"@type":102,"interactionType":103,"userInteractionCount":39},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Why are accurate BCS margins critical in breast-conserving surgery?","Question",{"text":112,"@type":113},"Negative margins reduce local tumor recurrence and distant metastasis, improving clinical outcomes. When margins are positive, local recurrence remains an issue.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What problem does the nanoprobe aim to solve during surgery and radiotherapy?",{"text":117,"@type":113},"It targets the lack of effective intraoperative margin evaluation for BCS and addresses the need for improved radiotherapy efficacy by enabling NIR-II fluorescence guidance and tumor sensitization.",{"name":119,"@type":110,"acceptedAnswer":120},"How does the proposed system enhance radiotherapy performance?",{"text":121,"@type":113},"Targeting tumors with the nanoprobe increases reactive oxygen species under X-ray irradiation, which improves RT sensitivity and reduces tumor progression in mice.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},385672,1790784314,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":39,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":36,"preview_page_count":19,"preview_urls":145},549758252649,"https://ap-avatar.wpscdn.com/avatar/8000253669c5317157?_k=1778319167496531819","RESEARCH ARTICLE  \n[www.advancedscience.com](www.advancedscience.com)  \nNovel Self-Assembled Multifunctional Nanoprobes for Second-Near-Infrared-Fluorescence-Image-Guided Breast Cancer Surgery and Enhanced Radiotherapy Eﬃcacy  \nYong-Qu Zhang, Wan-Ling Liu, Xiang-Jie Luo, Jun-Peng Shi, Yun-Zhu Zeng, Wei-Ling Chen, Wen-He Huang, Yuan-Yuan Zhu, Wen-Liang Gao, Rong-Hui Li, Zi-He Ming, Li-Xin Zhang, Rui-Qin Yang, Jia-Zheng Wang, and Guo-Jun Zhang*  \nBreast-conserving surgery (BCS) is the predominant treatment approach for initial breast cancer. However, due to a lack of eﬀective methods evaluating BCS margins, local recurrence caused by positive margins remains an issue. Accordingly, radiation therapy (RT) is a common modality in patients with advanced breast cancer. However, while RT also protects normal tissue and enhances tumor bed doses to improve therapeutic eﬀects, current radiosensitizers cannot meet these urgent clinical needs. To address this, a novel self-assembled multifunctional nanoprobe (NP) gadolinium (Gd)–diethylenetriaminepentaacetic acid–human serum albumin  \n(HSA)@indocyanine green–Bevacizumab (NPs-Bev) is synthesized to improve the eﬃcacy of ﬂuorescence-image-guided BCS and RT. Fluorescence image guidance of the second near infrared NP improves complete resection in tumor-bearing mice and accurately discriminates between benign and malignant mammary tissue in transgenic mice. Moreover, targeting tumors with NPs induces more reactive oxygen species under X-ray radiation therapy, which not only increases RT sensitivity, but also reduces tumor progression in mice. Interestingly, self-assembled NPs-Bev using HSA, the magnetic resonance contrast agent and Bevacizumab-targeting vascular growth factor A, which are clinically safe reagents, are safe in vitro and in vivo. Therefore, the novel self-assembled NPs provide a solid precision therapy platform to treat breast cancer.  \n1. Introduction  \nTumor-free surgical margins are critical parameters for breast-conserving surgery (BCS) as negative margins eﬀectively reduce local tumor recurrence and distant metastasis, thereby optimizing clinical outcomes for patients.[1] However, intraoperative tumor margin identiﬁcation and sensitivity is poor as it mainly relies on palpation and visual inspection. Speciﬁcally, ≈20– 40% of patients require further surgery or eventually undergo a mastectomy.[2] Resectomies increase complication risks, potentially delay systemic treatments, and increase costs and health care burdens. Also, intraoperative margin evaluation approaches remain challenging for conventional imaging methods such as X-ray radiography, magnetic resonance imaging (MRI), and computed tomography (CT), as sensitivity and speciﬁcity are often limited, and methods are diﬃcult to apply in operating rooms.[3] Thus, a real-time, speciﬁc modality evaluating margins is urgently required in clinical settings.[4] Recently,  \nY.-Q. Zhang, W.-L. Liu, W.-L. Chen, W.-H. Huang, Y.-Y. Zhu, W.-L. Gao, Z.-H. Ming, L.-X. Zhang, R.-Q. Yang, J.-Z. Wang, G.-J. Zhang Department of Breast-Thyroid-Surgery and Cancer Center  \nXiang’an Hospital of Xiamen University  \nSchool of Medicine  \nXiamen University  \nNo. 2000 East Xiang’an Road, Xiamen 361100, China  \nE-mail: [gjzhang@xah.xmu.edu.cn](gjzhang@xah.xmu.edu.cn)  \nThe ORCID identiﬁcation number(s) for the author(s) of this article  \ncan be found under [https://doi.org/10.1002/advs.202205294](https://doi.org/10.1002/advs.202205294)[ ](https://doi.org/10.1002/advs.202205294)© 2023 The Authors. Advanced Science published by Wiley-VCH GmbH. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.  \nDOI: 10.1002/advs.202205294  \nY.-Q. Zhang, W.-L. Liu, W.-L. Chen, W.-H. Huang, Y.-Y. Zhu, W.-L. Gao, R.-H. Li, Z.-H. Ming, L.-X. Zhang, R.-Q. Yang, J.-Z. Wang, G.-J. Zhang Fujian Key Laboratory of Precision Dia","cbCaiklT7I7S6e2N","https://ap.wps.com/l/cbCaiklT7I7S6e2N","pdf",5877178,16,"English","# Introduction\n## Breast-conserving surgery and margin identification challenges\n## Limitations of conventional imaging and need for real-time modalities\n## NIR-II fluorescence imaging for image-guided tumor surgery\n## Radiotherapy limitations and rationale for radiosensitizers","[{\"question\":\"Why are accurate BCS margins critical in breast-conserving surgery?\",\"answer\":\"Negative margins reduce local tumor recurrence and distant metastasis, improving clinical outcomes. When margins are positive, local recurrence remains an issue.\"},{\"question\":\"What problem does the nanoprobe aim to solve during surgery and radiotherapy?\",\"answer\":\"It targets the lack of effective intraoperative margin evaluation for BCS and addresses the need for improved radiotherapy efficacy by enabling NIR-II fluorescence guidance and tumor sensitization.\"},{\"question\":\"How does the proposed system enhance radiotherapy performance?\",\"answer\":\"Targeting tumors with the nanoprobe increases reactive oxygen species under X-ray irradiation, which improves RT sensitivity and reduces tumor progression in mice.\"}]","Novel Self-Assembled Multifunctional Nanoprobes for Second-Near-Infrared-Fluorescence-Image-Guided Breast Cancer Surgery and Enhanced Radiotherapy Efficacy | PDF",1790270512,[146,150,154,158],{"page_no":8,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/432895748465b9490feeeb1910fe3833.webp",983,1291,{"page_no":14,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/c04329a30f12b05fbc8fde7da12819a1.webp",982,1290,{"page_no":81,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/6db4542713e777826b230415d0453e24.webp",981,1289,{"page_no":19,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/3290bacfb1f2c292697cb035277ed0ac.webp",980,1287]