[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-374631-105":59,"doc-detail-374631-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","noninvasive-real-time-monitoring-of-cellular-spatiotemporal-dynamics-via-machine-learningenhanced-electrical-impedance-spectroscopy","Noninvasive real-time monitoring of cellular spatiotemporal dynamics via machine learning–enhanced electrical impedance spectroscopy","","Monitoring cellular spatiotemporal dynamics is essential for deciphering complex biological processes including organ development and cancer progression. A noninvasive, label-free platform is presented by integrating microelectrode arrays, electrical impedance spectroscopy (EIS), and machine learning to enable real-time observation. The method correlates EIS readouts with growth parameters from automated microscopy in mono- and coculture of normal and cancerous breast epithelial cells. An ML model predicts spatiotemporal evolution of cell density and size and classifies cell types solely from EIS, also tracking proliferation heterogeneities and cell competition.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/noninvasive-real-time-monitoring-of-cellular-spatiotemporal-dynamics-via-machine-learningenhanced-electrical-impedance-spectroscopy/374631/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/noninvasive-real-time-monitoring-of-cellular-spatiotemporal-dynamics-via-machine-learningenhanced-electrical-impedance-spectroscopy/374631.png","ImageObject",300,407,{"name":92,"@type":93},"Rizky","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-19","2026-09-23",true,{"@type":102,"interactionType":103,"userInteractionCount":52},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"Why is monitoring cellular spatiotemporal dynamics important?","Question",{"text":112,"@type":113},"It is crucial for understanding biological processes such as tissue morphogenesis, tissue repair, immune coordination during infection, and dysregulated states leading to disorders including cancer progression.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What problem does the proposed approach address compared with live-cell fluorescence microscopy?",{"text":117,"@type":113},"Live-cell fluorescence microscopy can introduce cytotoxicity from dyes and photodamage, and it can be difficult when optical access is limited. The new approach uses EIS with machine learning to monitor cells noninvasively and label-free.",{"name":119,"@type":110,"acceptedAnswer":120},"How does the machine learning component contribute to the monitoring results?",{"text":121,"@type":113},"An ML model uses only EIS recordings to predict the spatiotemporal evolution of cell density and size and to classify different cell types, with performance supported by correlations to microscopy-derived growth parameters.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},374631,1791214406,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":52,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":19,"preview_urls":146},962085564807,"https://ap-avatar.wpscdn.com/davatar_6f874abed73319feea01a86fa6f0fab8","ENGINEERING  \nNoninvasive real-time monitoring of cellularspatiotemporal dynamics via machine learning–enhanced electrical impedance spectroscopy  \nManuel Carrasco Yagüe1,2,3*, Xingjian Zhang1, Matthew Volpatti1, Yiming Wei1, Gor Lebedev2, Jean Gamby3, Abdul I. Barakat1*  \nMonitoring cellular spatiotemporal dynamics is essential for understanding complex biological processes such as organ development and cancer progression. Using live-cell fluorescence microscopy to track cellular dynamics is often limited by dye-induced cytotoxicity and cellular photodamage. Here, we demonstrate an alternative methodology combining microelectrode arrays, electrical impedance spectroscopy (EIS), and machine learning (ML) that enables real-time monitoring of cellular spatiotemporal dynamics in a noninvasive and label-free manner. The platform is applied to normal and cancerous breast epithelial cells in either mono-or coculture, correlating EIS measurements with cell growth parameters obtained from automated microscopy image analysis. An ML model is implemented to accurately predict the spatiotemporal evolution of cell density and size and to classify the different cell types based solely on EIS recordings. The technology is also shown to be capable of tracking pertinent biological processes including spatial heterogeneities in cell proliferation patterns and cell competition in coculture.  \nCopyright © 2025 the Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. no claim to original U.S.  \nGovernment Works. distributed under a Creative Commons Attribution nonCommercial license 4.0 (CC BY-nC) .  \nINTRODUCTION  \nUnderstanding how cells organize in both space and time is crucial for explaining a wide range of physiological and pathological processes. For instance, the proper regulation of cellular spatiotemporal dynamics plays a central role in tissue morphogenesis during embryonic development (1, 2), determines tissue repair and regeneration after injury (3–5), and coordinates immune responses during infection and inflammation, contributing to homeostasis (6, 7) . Conversely, dysregulation of cellular spatiotemporal dynamics can lead to various disorders including cardiovascular complications such as intimal hyperplasia and atherosclerosis (8, 9), impairment of neuronal function and cognitive decline in neurodegenerative diseases (10, 11), and tumor progression and cancer metastasis (12, 13) .  \nNow, the predominant method for monitoring cellular spatiotemporal dynamics is live-cell fluorescence microscopy (14). However, this technique suffers from several important limitations including cytotoxicity because of cell dye labeling (15, 16) and cell photodamage, particularly in the case of extended periods of light exposure (15, 17–19). Microscopic imaging is also problematic in scenarios where optical access to the sample of interest is limited. Therefore, there is a critical need for noninvasive, label-free methods that enable long-term monitoring of cellular spatiotemporal dynamics with minimal disruption of natural cellular processes.  \nAn alternative to microscopic imaging for monitoring live-cell activity is the use of electrical impedance spectroscopy (EIS), a powerful technique that measures how a system responds to an excitation signal from an applied alternating electric field across multiple frequencies. While EIS has traditionally been used to characterize electrical properties of materials, it has gained popularity in the study of biological systems because of the dielectric properties of the  \n1ladhyX, CnRS, École Polytechnique, 91120, France. 2Sensome, Massy 91300,  \ninstitut Polytechnique de Paris, Palaiseau France. 3C2n, CnRS, Université Paris-Saclay,  \nUniversité Paris Cité, Palaiseau 91120, France.  \n*[Corresponding author. email: manuel.carrasco-yaguee@polytechnique.edu](Corresponding author. email: manuel.carrasco-yaguee@polytechnique.edu) (M.C.Y.); [abdul.barakat@polytechnique","cbCaim9U9Bj2G6xI","https://ap.wps.com/l/cbCaim9U9Bj2G6xI","pdf",13184941,14,"English","# Introduction\n## Limitations of live-cell fluorescence microscopy\n## Electrical impedance spectroscopy (EIS) for biological monitoring\n## ML-enhanced EIS signal analysis and study aims","[{\"question\":\"Why is monitoring cellular spatiotemporal dynamics important?\",\"answer\":\"It is crucial for understanding biological processes such as tissue morphogenesis, tissue repair, immune coordination during infection, and dysregulated states leading to disorders including cancer progression.\"},{\"question\":\"What problem does the proposed approach address compared with live-cell fluorescence microscopy?\",\"answer\":\"Live-cell fluorescence microscopy can introduce cytotoxicity from dyes and photodamage, and it can be difficult when optical access is limited. The new approach uses EIS with machine learning to monitor cells noninvasively and label-free.\"},{\"question\":\"How does the machine learning component contribute to the monitoring results?\",\"answer\":\"An ML model uses only EIS recordings to predict the spatiotemporal evolution of cell density and size and to classify different cell types, with performance supported by correlations to microscopy-derived growth parameters.\"}]","Noninvasive real-time monitoring of cellular spatiotemporal dynamics via machine learning–enhanced electrical impedance spectroscopy | PDF",1790202052,35,[147,151,155,159],{"page_no":8,"url":148,"width":149,"height":150},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/c1b167752bd11b172d36a79bf44bf805.webp",983,1250,{"page_no":14,"url":152,"width":153,"height":154},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/2eee05f67d52eb52a11fd1e953c81bc1.webp",982,1249,{"page_no":81,"url":156,"width":157,"height":158},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/cabf3088eaec7ac07ddad374fb550a2b.webp",981,1248,{"page_no":19,"url":160,"width":161,"height":162},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-16/cc172e550c861a381de80e3164c287e4.webp",980,1247]