[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"doc-seo-462842-105":3,"detail-sidebar-cat-0-en-105":81,"doc-detail-462842-en":130},{"code":4,"msg":5,"data":6},0,"ok",{"site_id":7,"language":8,"slug":9,"title":10,"keywords":11,"description":12,"schema_data":13,"social_meta":74,"head_meta":76,"extra_data":78,"updated_unix":80},105,"en","near-azeotropic-ethanolwater-mixture-pervaporation-through-a-polyvinyl-alcohol-membrane-a-parametric-study-on-process-efficiency","Near Azeotropic Ethanol–Water Mixture Pervaporation Through a Polyvinyl Alcohol Membrane - A Parametric Study on Process Efficiency","","This study investigates how operating parameters affect the performance of a polyvinyl alcohol (PVA) membrane in pervaporation for separating ethanol–water mixtures near the azeotrope. Variations in feed composition, temperature, and permeate pressure are linked to separation efficiency, targeting conditions that balance ethanol purity and quantity. Statistical models from COMSOL Multiphysics® 6.3 simulations using a Box–Behnken design identify suitable regimes and high recuperation degrees above 99%.",{"@graph":14,"@context":73},[15,34,56],{"@type":16,"itemListElement":17},"BreadcrumbList",[18,23,27,31],{"item":19,"name":20,"@type":21,"position":22},"https://docshare.wps.com","Home","ListItem",1,{"item":24,"name":25,"@type":21,"position":26},"https://docshare.wps.com/document/","Document",2,{"item":28,"name":29,"@type":21,"position":30},"https://docshare.wps.com/document/research-report/","Research & Report",3,{"item":32,"name":10,"@type":21,"position":33},"https://docshare.wps.com/document/near-azeotropic-ethanolwater-mixture-pervaporation-through-a-polyvinyl-alcohol-membrane-a-parametric-study-on-process-efficiency/462842/",4,{"url":32,"name":10,"@type":35,"image":36,"author":41,"headline":10,"publisher":44,"fileFormat":47,"inLanguage":8,"description":12,"dateModified":48,"datePublished":49,"encodingFormat":47,"isAccessibleForFree":50,"interactionStatistic":51},"DigitalDocument",{"url":37,"@type":38,"width":39,"height":40},"https://docshare.wps.com/thumbnails/near-azeotropic-ethanolwater-mixture-pervaporation-through-a-polyvinyl-alcohol-membrane-a-parametric-study-on-process-efficiency/462842.png","ImageObject",300,407,{"name":42,"@type":43},"4398046744996","Person",{"url":19,"name":45,"@type":46},"DocShare","Organization","application/pdf","2026-11-04","2026-09-30",true,{"@type":52,"interactionType":53,"userInteractionCount":55},"InteractionCounter",{"@type":54},"ViewAction",9,{"@type":57,"mainEntity":58},"FAQPage",[59,65,69],{"name":60,"@type":61,"acceptedAnswer":62},"Which operating parameters were examined for PVA membrane pervaporation?","Question",{"text":63,"@type":64},"The study evaluates feed composition, temperature, and permeate pressure to determine their impact on separation efficiency for ethanol–water mixtures near the azeotrope.","Answer",{"name":66,"@type":61,"acceptedAnswer":67},"What modeling approach was used to generate the operating-condition data?",{"text":68,"@type":64},"COMSOL Multiphysics® 6.3 simulations were performed under various conditions, and statistical models were built using a Box–Behnken design.",{"name":70,"@type":61,"acceptedAnswer":71},"What operating conditions were reported as suitable near the azeotrope?",{"text":72,"@type":64},"Similar operating conditions around 100 °C and 4–5 kPa were found suitable, with recovery degrees generally above 99% for certain water-mass-fraction ranges.","https://schema.org",{"og:url":32,"og:type":75,"og:title":10,"og:site_name":45,"og:description":12},"article",{"robots":77,"canonical":32},"index,follow",{"doc_id":79,"site_id":7},462842,1791061953,{"code":4,"msg":82,"data":83},"success",[84,88,92,96,101,106,111,115,119,122,126],{"id":22,"doc_module":4,"doc_module_name":25,"category_name":85,"show_sort_weight":86,"slug":87},"Story & Novel",90,"story-novel",{"id":26,"doc_module":4,"doc_module_name":25,"category_name":89,"show_sort_weight":90,"slug":91},"Literature",80,"literature",{"id":33,"doc_module":4,"doc_module_name":25,"category_name":93,"show_sort_weight":94,"slug":95},"Exam",70,"exam",{"id":97,"doc_module":4,"doc_module_name":25,"category_name":98,"show_sort_weight":99,"slug":100},5,"Comic",60,"comic",{"id":102,"doc_module":4,"doc_module_name":25,"category_name":103,"show_sort_weight":104,"slug":105},6,"Technology",50,"technology",{"id":107,"doc_module":4,"doc_module_name":25,"category_name":108,"show_sort_weight":109,"slug":110},7,"Healthcare",40,"healthcare",{"id":112,"doc_module":4,"doc_module_name":25,"category_name":29,"show_sort_weight":113,"slug":114},8,30,"research-report",{"id":55,"doc_module":4,"doc_module_name":25,"category_name":116,"show_sort_weight":117,"slug":118},"Religion & Spirituality",20,"religion-spirituality",{"id":117,"doc_module":4,"doc_module_name":25,"category_name":120,"show_sort_weight":117,"slug":121},"World Cup","world-cup",{"id":123,"doc_module":4,"doc_module_name":25,"category_name":124,"show_sort_weight":123,"slug":125},10,"Lifestyle","lifestyle",{"id":127,"doc_module":4,"doc_module_name":25,"category_name":128,"show_sort_weight":97,"slug":129},19,"General","general",{"code":4,"msg":82,"data":131},{"doc_id":79,"user_id":132,"nickname":42,"user_avatar":11,"doc_module":4,"category_id":112,"category_name":29,"doc_title":10,"doc_description":12,"doc_content":133,"file_id":134,"file_url":135,"file_type":136,"file_size":137,"view_count":55,"is_deleted":4,"is_public":22,"is_downloadable":22,"audit_status":22,"page_count":138,"language":139,"language_code":8,"site_id":7,"html_lang":8,"table_of_contents":140,"faqs":141,"seo_title":142,"seo_description":12,"update_tm":143,"read_time":144,"preview_page_count":33,"preview_urls":145},4398046744996,"Article  \nNear Azeotropic Ethanol–Water Mixture Pervaporation Through a Polyvinyl Alcohol Membrane: A Parametric Study on Process Efficiency  \nCristiana Luminia Gîjiu, Daniel Dumitru Dinculescu * and Raluca Isopescu   \nAcademic Editors: S, tefan T, ˘alu and Alfredo Cassano  \nReceived: 23 November 2025  \nRevised: 12 December 2025  \nAccepted: 19 December 2025  \nPublished: 25 December 2025  \nCopyright: © 2025 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.  \nFaculty of Chemical Engineering and Biotechnologies, National University of Science and Technology POLITEHNICA Bucharest, 011061 Bucharest, Romania; [luminita.gijiu@upb.ro](luminita.gijiu@upb.ro) (C.L.G.);  \n[raluca.isopescu@upb.ro](raluca.isopescu@upb.ro) (R.I.)  \n* Correspondence: [daniel.dinculescu@upb.ro](daniel.dinculescu@upb.ro)  \nAbstract  \nThe goal of this study was to explore how different operating parameters influence the performance of a polyvinyl alcohol (PVA) membrane in pervaporation for separating ethanol–water mixtures. Specifically, the focus was on understanding how variations in feed composition, temperature, and permeate pressure affect the separation efficiency. The study aimed to provide a range of operating conditions that offer a balance between maximizing both the purity and quantity of ethanol. This was achieved through statistical models, which were generated by simulating the pervaporation process under various conditions using COMSOL Multiphysics® 6.3 and following a Box–Behnken design. It was found that similar operating conditions (temperature ~100 ◦ C; pressure ~4–5 kPa) are suitable for both kinds of mixtures near azeotrope, with higher water content (~0.15 mass fraction) and lower water content (~0.05 mass fraction) obtaining very high recuperation degrees (generally above 99%) . For more concentrated solutions (lower water content), it was possible to obtain optimal trade-off solutions (separation degree vs. retentate enrichment in ethanol), even at lower temperatures (~80 ◦ C) .  \nKeywords: PVA membrane; COMSOL modeling and simulation of ethanol–water pervaporation; multiobjective optimization of purity and productivity  \n1. Introduction  \nThere is a wide variety of processes that lead to the obtaining of azeotropic mixtures. Perhaps the best-known case is the ethyl alcohol/water azeotropic mixture, which needs to be separated in cases where (bio)ethanol is intended to be used as a (bio)fuel, for example. The butanol/water azeotrope also belongs to the same category [1] . As expected, the chemical industry also abounds in examples of azeotropic mixtures that appear in various manufacturing processes of certain chemical products: dimethyl carbonate/methanol [2,3], methanol/methyl-tert-butyl-ether [4], ethanol/ethyl-tert-butylether [5,6], benzene/cyclohexane [7], etc.  \nThe separation processes of azeotropic mixtures are usually energy and/or materialintensive (as is the case of the solvent used in separation by liquid–liquid extraction [8,9], extractive distillation [9–12], or azeotropic distillation [9,12]) . The separation processes are usually performed in two steps: a first step involving separation by classical processes until concentrations close to the azeotrope concentration are obtained, followed by a second step involving breaking the azeotrope and purifying the components. The first way to approach  \nthe separations of liquid mixtures (of course, where the difference between the boiling points of the components allows it) was (and still is) distillation/rectification [8–12] .  \nHowever, this separation option is only useful until the concentration corresponding to the azeotropic mixture is obtained. Therefore, to obtain pure components from such a mixture, membrane processes, in particular pervaporation, have been proposed [13,14] . Pervaporation does not suffer from the thermodynamic limitatio","cbCainihcW3w0Pzd","https://ap.wps.com/l/cbCainihcW3w0Pzd","pdf",2051850,18,"English","# Abstract\n# 1. Introduction\n## Azeotropic mixtures and separation challenges\n## Role of pervaporation membranes\n## Module design and industrial adoption\n## Energy and sustainability considerations","[{\"question\":\"Which operating parameters were examined for PVA membrane pervaporation?\",\"answer\":\"The study evaluates feed composition, temperature, and permeate pressure to determine their impact on separation efficiency for ethanol–water mixtures near the azeotrope.\"},{\"question\":\"What modeling approach was used to generate the operating-condition data?\",\"answer\":\"COMSOL Multiphysics® 6.3 simulations were performed under various conditions, and statistical models were built using a Box–Behnken design.\"},{\"question\":\"What operating conditions were reported as suitable near the azeotrope?\",\"answer\":\"Similar operating conditions around 100 °C and 4–5 kPa were found suitable, with recovery degrees generally above 99% for certain water-mass-fraction ranges.\"}]","Near Azeotropic Ethanol–Water Mixture Pervaporation Through a Polyvinyl Alcohol Membrane - A Parametric Study on Process Efficiency | PDF",1790765451,45,[146,150,154,158],{"page_no":22,"url":147,"width":148,"height":149},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/da42923652b5aff8a7a9c6fe82f2ddef.webp",983,1390,{"page_no":26,"url":151,"width":152,"height":153},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/6193189f69ffd107e79d39a469868894.webp",982,1388,{"page_no":30,"url":155,"width":156,"height":157},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/4d7e82827b1d1f51469855d8a0e9bd3e.webp",981,1387,{"page_no":33,"url":159,"width":160,"height":161},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/11da3115b3960988bc8681f7acc6121f.webp",980,1385]