[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"detail-sidebar-cat-0-en-105":3,"doc-seo-505839-105":59,"doc-detail-505839-en":130},{"code":4,"msg":5,"data":6},0,"success",[7,13,18,23,28,33,38,43,48,51,55],{"id":8,"doc_module":4,"doc_module_name":9,"category_name":10,"show_sort_weight":11,"slug":12},1,"Document","Story & Novel",90,"story-novel",{"id":14,"doc_module":4,"doc_module_name":9,"category_name":15,"show_sort_weight":16,"slug":17},2,"Literature",80,"literature",{"id":19,"doc_module":4,"doc_module_name":9,"category_name":20,"show_sort_weight":21,"slug":22},4,"Exam",70,"exam",{"id":24,"doc_module":4,"doc_module_name":9,"category_name":25,"show_sort_weight":26,"slug":27},5,"Comic",60,"comic",{"id":29,"doc_module":4,"doc_module_name":9,"category_name":30,"show_sort_weight":31,"slug":32},6,"Technology",50,"technology",{"id":34,"doc_module":4,"doc_module_name":9,"category_name":35,"show_sort_weight":36,"slug":37},7,"Healthcare",40,"healthcare",{"id":39,"doc_module":4,"doc_module_name":9,"category_name":40,"show_sort_weight":41,"slug":42},8,"Research & Report",30,"research-report",{"id":44,"doc_module":4,"doc_module_name":9,"category_name":45,"show_sort_weight":46,"slug":47},9,"Religion & Spirituality",20,"religion-spirituality",{"id":46,"doc_module":4,"doc_module_name":9,"category_name":49,"show_sort_weight":46,"slug":50},"World Cup","world-cup",{"id":52,"doc_module":4,"doc_module_name":9,"category_name":53,"show_sort_weight":52,"slug":54},10,"Lifestyle","lifestyle",{"id":56,"doc_module":4,"doc_module_name":9,"category_name":57,"show_sort_weight":24,"slug":58},19,"General","general",{"code":4,"msg":60,"data":61},"ok",{"site_id":62,"language":63,"slug":64,"title":65,"keywords":66,"description":67,"schema_data":68,"social_meta":123,"head_meta":125,"extra_data":127,"updated_unix":129},105,"en","national-environmental-laboratory-accreditation-conference-nelac-on-site-laboratory-assessment-chemistry-checklist","NATIONAL ENVIRONMENTAL LABORATORY ACCREDITATION CONFERENCE (NELAC) - ON-SITE LABORATORY ASSESSMENT - CHEMISTRY CHECKLIST","","Chemistry checklist for on-site laboratory assessment under the National Environmental Laboratory Accreditation Conference (NELAC). Provides general instructions for completing inspection items with check marks, X marks, or N/A, and directs assessors to cite specific NELAC standards in bold numerals. Includes criteria for facility and access requirements, documentation of laboratory facility adherence, support equipment checks, reagent and standards handling, container labeling, preservation of samples, and applicable EPA/SM methods for chemical processes and safety controls.",{"@graph":69,"@context":122},[70,84,105],{"@type":71,"itemListElement":72},"BreadcrumbList",[73,77,79,82],{"item":74,"name":75,"@type":76,"position":8},"https://docshare.wps.com","Home","ListItem",{"item":78,"name":9,"@type":76,"position":14},"https://docshare.wps.com/document/",{"item":80,"name":40,"@type":76,"position":81},"https://docshare.wps.com/document/research-report/",3,{"item":83,"name":65,"@type":76,"position":19},"https://docshare.wps.com/document/national-environmental-laboratory-accreditation-conference-nelac-on-site-laboratory-assessment-chemistry-checklist/505839/",{"url":83,"name":65,"@type":85,"image":86,"author":91,"headline":65,"publisher":94,"fileFormat":97,"inLanguage":63,"description":67,"dateModified":98,"datePublished":99,"encodingFormat":97,"isAccessibleForFree":100,"interactionStatistic":101},"DigitalDocument",{"url":87,"@type":88,"width":89,"height":90},"https://docshare.wps.com/thumbnails/national-environmental-laboratory-accreditation-conference-nelac-on-site-laboratory-assessment-chemistry-checklist/505839.png","ImageObject",300,407,{"name":92,"@type":93},"Sarah ","Person",{"url":74,"name":95,"@type":96},"DocShare","Organization","application/pdf","2026-11-16","2026-10-04",true,{"@type":102,"interactionType":103,"userInteractionCount":52},"InteractionCounter",{"@type":104},"ViewAction",{"@type":106,"mainEntity":107},"FAQPage",[108,114,118],{"name":109,"@type":110,"acceptedAnswer":111},"How should inspectors mark checklist items when a laboratory meets or fails a NELAC standard?","Question",{"text":112,"@type":113},"Use a check mark in the blank if the laboratory meets the referenced NELAC standard. Use an X-mark if the standard is not met and the laboratory must create an acceptable Plan of Correction with an estimated completion date. Mark N/A when the standard is not applicable.","Answer",{"name":115,"@type":110,"acceptedAnswer":116},"What should a laboratory do if it appears to meet a NELAC standard but lacks supporting documentation?",{"text":117,"@type":113},"Use the provided instruction to address missing documentation, including referencing the relevant NELAC standard(s) for which accompanying data was not available for review.",{"name":119,"@type":110,"acceptedAnswer":120},"What requirements are specified for prepared standards, reference materials, and reagents?",{"text":121,"@type":113},"Prepared containers must bear a unique identifier, expiration date, and link to the specific preparation record. Procedures must ensure prepared reagents meet the test method requirements, and container labeling should document purity compliance, preparation dates, and expiration dates.","https://schema.org",{"og:url":83,"og:type":124,"og:title":65,"og:site_name":95,"og:description":67},"article",{"robots":126,"canonical":83},"index,follow",{"doc_id":128,"site_id":62},505839,1791459003,{"code":4,"msg":5,"data":131},{"doc_id":128,"user_id":132,"nickname":92,"user_avatar":133,"doc_module":4,"category_id":39,"category_name":40,"doc_title":65,"doc_description":67,"doc_content":134,"file_id":135,"file_url":136,"file_type":137,"file_size":138,"view_count":52,"is_deleted":4,"is_public":8,"is_downloadable":8,"audit_status":8,"page_count":139,"language":140,"language_code":63,"site_id":62,"html_lang":63,"table_of_contents":141,"faqs":142,"seo_title":143,"seo_description":67,"update_tm":144,"read_time":145,"preview_page_count":146,"preview_urls":147},962085320529,"https://ap-avatar.wpscdn.com/davatar_9964176cb1d06d4a9deccf72a44ae3dc","NATIONAL ENVIRONMENTAL LABORATORY ACCREDITATION CONFERENCE (NELAC)  \nON-SITE LABORATORY ASSESSMENT  \nCHEMISTRY CHECKLIST (103 PAGES TOTAL)  \nLABORATORY:   Physical Address:    \nMailing Address:  (if different from above)  \n____________________________________________________________________________  \nTelephone Number:   Facsimile Number:   E-mail address:    \nINSPECTED BY: (Name) (Affiliation)  \n______________________________ _________________________________  \n______________________________ _________________________________  \n______________________________ _________________________________  \nINSPECTION DATES:    \nLABORATORY TECHNICAL DIRECTORS AND MANAGEMENT:  \n(Name) (Title)  \n______________________________ _________________________________  \n______________________________ _________________________________  \n______________________________ _________________________________  \n______________________________ _________________________________  \n______________________________ _________________________________  \n______________________________ _________________________________  \n______________________________ _________________________________  \n______________________________ _________________________________  \n______________________________ _________________________________  \n______________________________ _________________________________  \nGENERAL INSTRUCTIONS: Before each item is a blank line and a NELAC Standard citation in Bold Numerals.  \nPlace a check mark ( \\__ ---- ) in the blank if the laboratory meets the NELAC Standard referenced.  \nPlace an X-mark ( X ) in the blank if the Standard is not met and the laboratory must devise an acceptable Plan of Correction and estimated completion date. The NELAC Standard reference must be cited in in the on-site assessment report.  \nMark \"N/A\" in the blank if the NELAC Standard is not applicable to this laboratory, either because of the nature of its business mission, because of the analytical tests it performs, or because of the situation never ever happening.  \nSee individual Technology Checklists for specific requirements on Reagents & Standards, Test Method Standard Operating Procedures, Instrument Calibrations, Demonstrations of Capability, Quality Control, Detection Limits, and Selectivity, as applicable  \nNotes:  \nIf the laboratory appears to meet a particular NELAC Standard but does not have the documentation to back up its claim, use the following:  \n  5.0 Does the laboratory have all items identified in NELAC Chapter 5 Quality Systems available  \nfor on-site inspection or data audit  \nComment: (list all applicable Standards where the accompanying data was not available for review)  \nCHEMISTRY LABORATORY TOUR  \n  [5.5.3.2](5.5.3.2) Does the laboratory meet & document adherence to laboratory facility requirements specified  \nby a test method or regulation  \nEPA 508A – fume hood for handling SbCl5 (PCB perchlorination)  \nEPA 515.1, 515.2, 615, 8151; SM6251B – fume hood with safety shield for diazomethane generation (Herbicides)  \nEPA 613, 1613, 8280, 8290 – controlled access work areas, adequate ventilation, analyst training (Dioxins)  \nEPA 9010, 9012 – fume hood & amber light with cyanogen chloride generation (Amenable Cyanide treatment)  \nEPA 9030, 9031 – fume hood (Sulfide distillations)  \nSM4500CN-B – fume hood (all sample manipulations that may contain toxic Cyanide)  \n  5.5.5.2.1(d) Does the laboratory’s support equipment checks meet the following needs of the analysis or  \nor application for which the equipment is being used  \nEPA 245.1, 7470, 7471; SM3112B – 95 degrees Celsius to avoid Hg loss in boiling solution  \nEPA 245.2 – 105 degrees Celsius  \nEPA 351.x, SM4500Norg B & C – 365-380 degrees Celsius, Kjeldahl Nitrogen digestion until white SO3 fumes are expelled & for 30 minutes thereafter  \nSM4500F-B – discontinue HF distillation above 180 degrees Celsius to prevent H2SO4 carryover SM5210B – 19-21 degrees Celsius during the 5-day BOD or CBOD incubations  \nResidues – 18","cbCaif4rFv8Oyg7f","https://ap.wps.com/l/cbCaif4rFv8Oyg7f","pdf",397789,103,"English","# GENERAL INSTRUCTIONS\n# CHEMISTRY LABORATORY TOUR\n## Facility requirements adherence and documentation\n## Support equipment checks for analysis needs\n## Prepared standards and reference materials labeling\n## Prepared reagent and container procedures\n## Sample preservation checks","[{\"question\":\"How should inspectors mark checklist items when a laboratory meets or fails a NELAC standard?\",\"answer\":\"Use a check mark in the blank if the laboratory meets the referenced NELAC standard. Use an X-mark if the standard is not met and the laboratory must create an acceptable Plan of Correction with an estimated completion date. Mark N/A when the standard is not applicable.\"},{\"question\":\"What should a laboratory do if it appears to meet a NELAC standard but lacks supporting documentation?\",\"answer\":\"Use the provided instruction to address missing documentation, including referencing the relevant NELAC standard(s) for which accompanying data was not available for review.\"},{\"question\":\"What requirements are specified for prepared standards, reference materials, and reagents?\",\"answer\":\"Prepared containers must bear a unique identifier, expiration date, and link to the specific preparation record. Procedures must ensure prepared reagents meet the test method requirements, and container labeling should document purity compliance, preparation dates, and expiration dates.\"}]","NATIONAL ENVIRONMENTAL LABORATORY ACCREDITATION CONFERENCE (NELAC) - ON-SITE LABORATORY ASSESSMENT - CHEMISTRY CHECKLIST | PDF",1791154924,260,11,[148,152,156,160,164,168,172,176,180,184,188],{"page_no":8,"url":149,"width":150,"height":151},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/1238a78085b6dd693272ae8c9dc1e837.webp",983,1272,{"page_no":14,"url":153,"width":154,"height":155},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/fcb8f76437d1849baac4bd397348860d.webp",982,1270,{"page_no":81,"url":157,"width":158,"height":159},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/7e16253de22997eecda8cf8d30f504eb.webp",981,1269,{"page_no":19,"url":161,"width":162,"height":163},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/d9a5ae6358408644560fc0685b6aa7c6.webp",980,1268,{"page_no":24,"url":165,"width":166,"height":167},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/61b28e707b31a80f4457d257617502b6.webp",979,1267,{"page_no":29,"url":169,"width":170,"height":171},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/f0a94fcef7db8baf9a211de771ec35ca.webp",978,1265,{"page_no":34,"url":173,"width":174,"height":175},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/04ed7a8bfbd8f398af047a3b217b28c2.webp",977,1264,{"page_no":39,"url":177,"width":178,"height":179},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/f6187240a5d43958553de4f5cf1200b4.webp",976,1263,{"page_no":44,"url":181,"width":182,"height":183},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/fce556ba7782a10ad5b626da345914eb.webp",975,1261,{"page_no":52,"url":185,"width":186,"height":187},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/83e38e3bd2b9cc8fa46181257c24d6e7.webp",974,1260,{"page_no":146,"url":189,"width":190,"height":191},"https://res-academy.cache.wpscdn.com/upload/kdocshare/2026-11-17/e735f5e9a2076c11030f442d75cd3079.webp",973,1259]